Model-based thermodynamic analysis of direct air capture units in repurposed power plant cooling towers

被引:0
|
作者
Sager, Robert [1 ]
Pehle, Lukas [1 ]
Petersen, Nils Hendrik [1 ]
Wirsum, Manfred [1 ]
Hannes, Jens [2 ]
机构
[1] Rhein Westfal TH Aachen, Inst Power Plant Technol Steam & Gas Turbines, Aachen, Germany
[2] RWE Power AG, Res & Dev, Essen, Germany
关键词
Direct air capture; Cooling tower; Repurpose; CARBON-DIOXIDE; MASS-TRANSFER; WETTED WALL; CO2; ABSORPTION; KINETICS; PLUME; COST;
D O I
10.1016/j.apenergy.2024.124668
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To achieve the climate goals, the energy supply system must be sourced by renewable energy instead of fossil fuels. Nevertheless, hard-to-abate sectors require negative emission technologies (NETs) to counteract their emissions. Thus, NETs playa significant role across all future scenarios considered. Since natural NETs, such as afforestation, exhibit lower scaling potential, technological approaches like Direct Air Capture (DAC) represent promising alternatives. However, DAC faces major drawbacks in terms of high energy demands and high required air mass flows due to the low CO2 concentration in ambient air (similar to 400 ppm). This results in elevated costs per captured tonne of CO2. Interestingly, the infrastructure of thermal power plants shares similarities with components of DAC units, in particular the cooling tower due to its handling of high air mass flows. As countries progressively shut down their coal-fired power plants, there is an opportunity to repurpose existing power plant infrastructure into DAC units. Thus, this work investigates the opportunities and challenges of repurposing thermal power plant cooling towers as air contactors of DAC units with a potential of several million tonnes of CO2 captured per year. The investigation focuses on the integration of an absorption-based liquid DAC process into a wet cooling tower. Therefore, the influence of the repurposed geometry of the cooling tower and its internal packing on the operational behavior of the air contactor is analyzed for the cooling towers of the coal power Niederau ss em in Germany using a two-film theory-based model. It can be observed that the repurposed geometry of the absorber enables higher air velocities due to lower pressure losses. At the same time, the reduced travel depth in cooling towers causes a lower capture rate than in geometries optimized for DAC, ultimately resulting in 50-150 tCO2/a per cooling tower. Finally, a sensitivity analysis shows that the effect of the correlations of mass transfer and volume specific surface areas is not negligible.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Robust model-based approach to diagnosing faults in air-handling units
    Univ of Oxford, Oxford, United Kingdom
    ASHRAE Trans, (PART 1/-):
  • [32] QUALITATIVE MODEL-BASED FAULT-DETECTION IN AIR-HANDLING UNITS
    GLASS, AS
    GRUBER, P
    ROOS, M
    TODTLI, J
    IEEE CONTROL SYSTEMS MAGAZINE, 1995, 15 (04): : 11 - 22
  • [33] Model-based fault detection and diagnosis of air handling units: A comparison of methodologies
    Sterling, Raymond
    Provan, Gregory
    Febres, Jesus
    O'Sullivan, Dominic
    Struss, Peter
    Keane, Marcus M.
    6TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, 2014, 62 : 686 - 693
  • [34] Effect of Sensor Redundancy on Model-Based Fault Detectability for Air Handling Units
    Torabi, Narges
    Gunay, H. Burak
    O'Brien, William
    ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 : 475 - 483
  • [35] Model-based motion capture for crash test video analysis
    Gall, Juergen
    Rosenhahn, Bodo
    Gehrig, Stefan
    Seidel, Hans-Peter
    PATTERN RECOGNITION, 2008, 5096 : 92 - +
  • [36] Hierarchical model-based predictive control of a power plant portfolio
    Edlund, K.
    Bendtsen, J. D.
    Jorgensen, J. B.
    CONTROL ENGINEERING PRACTICE, 2011, 19 (10) : 1126 - 1136
  • [37] Model-based System Safety Assessment of Aircraft Power Plant
    Li, Yan
    Gong, Qi
    Su, Duo
    3RD INTERNATIONAL SYMPOSIUM ON AIRCRAFT AIRWORTHINESS (ISAA 2013), 2014, 80 : 85 - 92
  • [38] Discrete model-based operation of cooling tower based on statistical analysis
    Wang, Jian-Guo
    Shieh, Shyan-Shu
    Jang, Shi-Shang
    Wu, Chan-Wei
    ENERGY CONVERSION AND MANAGEMENT, 2013, 73 : 226 - 233
  • [39] A model-based direct power control for three-phase power converters
    Vazquez, Sergio
    Sanchez, Juan Antonio
    Carrasco, Juan Manuel
    Leon, Jose Ignacio
    Galvan, Eduardo
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (04) : 1647 - 1657
  • [40] Data Center Cooling Management and Analysis - A Model-Based Approach
    Zhou, Rongliang
    Wang, Zhikui
    Bash, Cullen E.
    McReynolds, Alan
    2012 28TH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM (SEMI-THERM), 2012, : 98 - 103