Colorectal Cancer Label-Free Impedimetric Immunosensor for Blood-Based Biomarker CCSP-2

被引:0
|
作者
Paul, Ruma [1 ]
Morales-Lozada, Yermary [1 ]
Colon, Brian J. Sanchez [2 ]
Hernandez, Andrea R. [1 ]
Roy, Sourav [3 ]
Cabrera, Carlos R. [1 ]
机构
[1] Univ Texas El Paso, Dept Chem & Biochem, El Paso, TX 79968 USA
[2] Univ Puerto Rico, Dept Chem, Rio Piedras Campus, San Juan, PR 00925 USA
[3] Univ Texas El Paso, Dept Biol Sci, El Paso, TX 79968 USA
来源
ACS MEASUREMENT SCIENCE AU | 2025年 / 5卷 / 01期
基金
美国国家科学基金会;
关键词
immunosensor; CCSP-2; colorectal cancer; electrochemical impedance spectroscopy; label-free; PROTEIN-G;
D O I
10.1021/acsmeasuresciau.4c00073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Colorectal cancer (CRC) is one of the most treatable cancers, yet it ranks second in mortality worldwide. Early detection significantly impacts treatment outcomes, but early stage CRC often presents no symptoms or nonspecific symptoms. The current screening methods are invasive and lacks specificity, hindering widespread CRC screening efforts. This underscores the urgent need for improved CRC screening tools. In this study, a label-free impedimetric immunosensor for detecting colon cancer-secreted protein-2 (CCSP-2), which exhibits a mean 78-fold increase in primary colon cancers compared to normal mucosa, was developed. Our cost-effective and noninvasive electrochemical immunosensor for CCSP-2 biomarker detection aims to facilitate early diagnosis and monitoring of CRC. The designed immunosensor features a functionalized gold electrode (Au) modified with cysteine-modified recombinant protein G (RPGCys) to immobilize the CCSP-2 antibody (Ab), and bovine serum albumin (BSA) used to prevent sensor surface fouling. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed to analyze the electrochemical response to the binding of CCSP-2 antigen (Ag) and Ab. The changes in relative charge transfer resistance (Delta R ct/R cti) with varying concentrations of Ag were plotted and a calibration curve was established between Delta R ct/R cti and logarithm of Ag concentration to assess sensor's sensitivity. The sensor demonstrated a linear response (R 2 = 0.95) within the range of 10-100 ng/mu L, plateauing after 100 ng/mu L, with a detection limit of 0.71 ng/mu L. Statistical analysis of specificity and selectivity studies showed significant differences in Ag detection compared to blank and nonspecific protein BSA, both with and without cell extracts. This immunosensor effectively detects the CRC biomarker CCSP-2 with high sensitivity and specificity. Integrating this sensor with other sensors for serum CRC biomarkers present a promising approach for developing diagnostic and prognostic tools for CRC.
引用
收藏
页码:87 / 95
页数:9
相关论文
共 50 条
  • [31] Impedimetric aptasensor for the label-free and selective detection of Interleukin-6 for colorectal cancer screening
    Tertis, Mihaela
    Leva, Petrica Ionut
    Bogdan, Diana
    Suciu, Maria
    Graur, Florin
    Cristea, Cecilia
    BIOSENSORS & BIOELECTRONICS, 2019, 137 : 123 - 132
  • [32] Development of a Label-Free Immunosensor for Clusterin Detection as an Alzheimer's Biomarker
    Islam, Kamrul
    Damiati, Samar
    Sethi, Jagriti
    Suhail, Ahmed
    Pan, Genhua
    SENSORS, 2018, 18 (01)
  • [33] Label-free electrochemical immunosensor for picomolar detection of the cervical cancer biomarker MCM5
    Barhoum, Ahmed
    Forster, Robert J.
    ANALYTICA CHIMICA ACTA, 2022, 1225
  • [34] A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodes
    Foguel, Marcos Vinicius
    Giordano, Gabriela Furlan
    de Sylos, Celia Maria
    Carlos, Iracilda Zeppone
    Pupim Ferreira, Antonio Aparecido
    Benedetti, Assis Vicente
    Yamanaka, Hideko
    CHEMOSENSORS, 2016, 4 (03)
  • [35] Cell-Free DNA as a Diagnostic Blood-Based Biomarker for Colorectal Cancer: A Systematic Review
    Petit, Joel
    Carroll, Georgia
    Gould, Tiffany
    Pockney, Peter
    Dun, Matthew
    Scott, Rodney J.
    JOURNAL OF SURGICAL RESEARCH, 2019, 236 : 184 - 197
  • [36] Label-free impedimetric immunosensors for liver cancer stem cells
    Eissa, Shimaa
    Chinnappan, Raja
    Zourob, Mohammed
    BIOSENSORS 2016, 2017, 27 : 287 - 289
  • [37] A SIMPLE, HIGHLY SENSITIVE, AND LABEL-FREE IMPEDIMETRIC IMMUNOSENSOR FOR DETECTION OF MICROCYSTIN-LR IN WATER
    Sun, Xiulan
    Shi, Hui
    Wang, Hongxin
    Xiao, Liwen
    Li, Luning
    ANALYTICAL LETTERS, 2010, 43 (04) : 533 - 544
  • [38] A label-free multisensing immunosensor based on imaging ellipsometry
    Wang, ZH
    Jin, G
    ANALYTICAL CHEMISTRY, 2003, 75 (22) : 6119 - 6123
  • [39] Label-free electrochemical impedimetric immunosensor for sensitive detection of IgM rheumatoid factor in human serum
    Chinnadayyala, Somasekhar R.
    Park, Jinsoo
    Abbasi, Muhammad A.
    Choa, Sungbo
    BIOSENSORS & BIOELECTRONICS, 2019, 143
  • [40] Label-free impedimetric immunosensor for point-of-care detection of COVID-19 antibodies
    Lian C. T. Shoute
    Gaser N. Abdelrasoul
    Yuhao Ma
    Pedro A. Duarte
    Cole Edwards
    Ran Zhuo
    Jie Zeng
    Yiwei Feng
    Carmen L. Charlton
    Jamil N. Kanji
    Shawn Babiuk
    Jie Chen
    Microsystems & Nanoengineering, 9