An inquiry into the accuracy of the energy model calibration process

被引:0
|
作者
Yilmaz, Ipek [1 ]
Gunay, H. Burak [1 ]
Newsham, Guy R. [2 ]
Wills, Adam D. [2 ]
机构
[1] Carleton Univ, Ottawa, ON, Canada
[2] Natl Res Council Canada, Ottawa, ON, Canada
关键词
OFFICE BUILDINGS; OPTIMIZATION; PLUG; LOADS;
D O I
10.26868/25222708.2021.30658
中图分类号
学科分类号
摘要
A calibrated physics-based energy model is mostly assumed to be an adequate representation of the actual building when it complies with a measurement and verification standard's criteria for fitness. This paper aims at quantifying the uncertainty inherent in the building energy model (BEM) calibration process and calibrated model's predictive performance on operational decisions. In this regard, a generic building is simulated with three different occupancy and envelope scenarios using EnergyPlus. Subsequently, seven parameters are assumed unknown, and a custom optimization script is employed to search for these parameters. Results demonstrated that calibration with hourly meter data yields more accurate and stable parameter estimates than monthly data. However, accuracy is increased up to 58% by repeating the monthly calibration a few times, averaging the parameter estimates, and adopting them as final calibrated model parameters. Results indicated that the poorly calibrated models might not be sufficient to support operational decisions.
引用
收藏
页码:1857 / 1864
页数:8
相关论文
共 50 条
  • [21] PROCESS OF INQUIRY
    不详
    NEW SCIENTIST, 1985, 106 (1460) : 2 - 2
  • [22] Distortion model selecting and accuracy evaluation for CCD camera calibration
    Zhou, GQ
    Tang, XF
    Yuan, BZ
    ICSP '96 - 1996 3RD INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, PROCEEDINGS, VOLS I AND II, 1996, : 875 - 878
  • [23] Measurement robot calibration model and algorithm based on distance accuracy
    Ren, Yong-Jie
    Zhu, Ji-Gui
    Yang, Xue-You
    Ye, Sheng-Hua
    Jiliang Xuebao/Acta Metrologica Sinica, 2008, 29 (03): : 198 - 202
  • [24] Improving the Accuracy of Hydrodynamic Model Predictions Using Lagrangian Calibration
    Mardani, Neda
    Suara, Kabir
    Fairweather, Helen
    Brown, Richard
    McCallum, Adrian
    Sidle, Roy C.
    WATER, 2020, 12 (02)
  • [25] Accuracy of Hospital Standardized Mortality Rates: Effects of Model Calibration
    Kipnis, Patricia
    Liu, Vincent
    Escobar, Gabriel J.
    MEDICAL CARE, 2014, 52 (04) : 378 - 384
  • [26] High accuracy energy determination and calibration of synchrotron radiation by powder diffraction
    Tantau, U.
    Islam, M. T.
    Payne, A. T.
    Tran, C. Q.
    Cheah, M. H.
    Best, S. P.
    Chantler, C. T.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 73 - 77
  • [27] Extended Calibration of Charge Mode Accelerometers to Improve the Accuracy of Energy Systems
    Tomczyk, Krzysztof
    ENERGIES, 2023, 16 (22)
  • [28] Machine learning parallel system for integrated process-model calibration and accuracy enhancement in sewer-river system
    Li, Yundong
    Ma, Lina
    Huang, Jingshui
    Disse, Markus
    Zhan, Wei
    Li, Lipin
    Zhang, Tianqi
    Sun, Huihang
    Tian, Yu
    ENVIRONMENTAL SCIENCE AND ECOTECHNOLOGY, 2024, 18
  • [29] Influences of energy data on Bayesian calibration of building energy model
    Lim, Hyunwoo
    Zhai, Zhiqiang
    APPLIED ENERGY, 2018, 231 : 686 - 698
  • [30] Optimization Tools for Building Energy Model Calibration
    Lara, Rigoberto Arambula
    Naboni, Emanuele
    Pernigotto, Giovanni
    Cappelletti, Francesca
    Zhang, Yi
    Barzon, Furio
    Gasparella, Andrea
    Romagnoni, Piercarlo
    8TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, SEB-16, 2017, 111 : 1060 - 1069