A Robust Backstepping Controller Based on Nonlinear Observer for Shunt Active Filters to Improve Power Quality in Four-Wire Distribution Systems

被引:0
|
作者
Sarafrazi, Parisa [1 ]
Taher, Seyed Abbas [1 ]
Akhavan, Ali [2 ]
机构
[1] Univ Kashan, Fac Elect & Comp Engn, Kashan, Iran
[2] Aalborg Univ, AAU Energy, Aalborg, Denmark
来源
关键词
- Harmonic and interharmonic grid currents; Backstepping control; Nonlinear disturbance observer; Active power filter; Four-wire distribution system; Power quality; SLIDING MODE CONTROL; GRID-CONNECTED INVERTERS; REPETITIVE CONTROLLER; DESIGN; COMPENSATION; STRATEGY;
D O I
10.5455/jjee.204-1700421844
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article introduces a novel approach to enhance the performance of LCL based active power filters (APFs) in four-wire distribution systems by employing a nonlinear current control strategy. The strategy combines backstepping control (BSC) and a nonlinear disturbance observer (NDOB) to effectively manage harmonic and interharmonic grid currents. By situating the shunt active power filter (SAPF) at the point of common coupling (PCC) via the LCL filter, the technique ensures that grid connected currents remain balanced and purely sinusoidal. The integration of NDOB with BSC aims to fortify the resilience of BSC against disturbances. Consequently, any disturbances occurring within the system are precisely estimated by the NDOB and subsequently mitigated through the BSC mechanism. Notably, this approach showcases robust adaptability across diverse scenarios, encompassing external disturbances, variations in filter parameters, nonlinear loads laden with harmonics and interharmonics, load imbalances, and non-ideal grid voltages. Its performance remains robust and stable even when disturbances are present. Comparative analysis with linear-based methodologies underscores the advantages of this approach, revealing quicker and smoother transient responses. The efficacy of the proposed technique is demonstrated through comprehensive simulation studies, substantiating its potential for significantly advancing power quality in complex distribution systems.
引用
收藏
页码:520 / 540
页数:21
相关论文
共 50 条
  • [21] Four-wire shunt active power filter with adaptive selective current compensation
    Villalva, MG
    Ernesto, RF
    2005 IEEE 36TH POWER ELECTRONIC SPECIALISTS CONFERENCE (PESC), VOLS 1-3, 2005, : 347 - 353
  • [22] Simulation of Three-phase Four-wire Shunt Active Power Filter
    Wang, Jidong
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1702 - 1705
  • [23] Selective shunt active power compensator applied in four-wire electrical systems based on IEEE Std. 1459
    Orts-Grau, Salvador
    Ginieno-Sales, Francisco J.
    Segui-Chilet, Salvador
    Abellan-Garcia, Antonio
    Alcaniz-Fillol, Miguel
    Masot-Peris, Rafael
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2563 - 2574
  • [24] A control strategy for four-wire shunt active filters using instantaneous active and reactive current method
    de Morais, Aniel Silva
    Barbi, Ivo
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 577 - +
  • [25] Robust Adaptive Variable Structure Controller for Shunt Active Power Filters
    Stefanello, Marcio
    Grundling, Hilton Abilio
    IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, : 5208 - 5213
  • [26] Minimization of Cable Losses in Three-Phase Four-Wire Systems by means of Instantaneous Compensation with Shunt Active Filters
    Artemenko, M. Yu.
    Batrak, L. M.
    Polishchuk, S. Y.
    Mykhalskyi, V. M.
    Shapoval, I. A.
    2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 359 - 362
  • [27] A Cascaded Inverter Based Hybrid Shunt Active Filter to Improve the Power Quality of 415V 50Hz four wire Distribution Systems
    Sellakumar, S.
    Vijayakumar, M.
    2014 IEEE NATIONAL CONFERENCE ON EMERGING TRENDS IN NEW & RENEWABLE ENERGY SOURCES AND ENERGY MANAGEMENT (NCET NRES EM), 2014, : 200 - 203
  • [28] Control of a shunt active power filter based on a three-leg four-wire electronic converter
    Garcia-Gonzalez, P.
    Garcia-Cerrada, A.
    Pinzon-Ardila, O.
    CPE: 2009 COMPATIBILITY AND POWER ELECTRONICS, 2009, : 292 - 297
  • [29] Energy control of three-phase four-wire shunt active power filter
    Rodríguez, P
    Pindado, R
    Pou, J
    IECON'03: THE 29TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1 - 3, PROCEEDINGS, 2003, : 1061 - 1066
  • [30] Performance Analysis of Three-phase Four-wire Shunt Active Power Filter
    Vanjani, Harsha
    Choudhury, U. K.
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON RELIABILTY, OPTIMIZATION, & INFORMATION TECHNOLOGY (ICROIT 2014), 2014, : 496 - 500