Beat-to-Beat Oscillometric Blood Pressure Estimation: A Bayesian Approach With System Identification

被引:1
|
作者
Farzam, Ramin [1 ,2 ]
Azad, Mohammad Hasan [1 ,2 ]
Moghaddam, Hamid Abrishami [3 ]
Forouzanfar, Mohamad [1 ,3 ,4 ]
机构
[1] Ecole Technol Super, Dept Syst Engn, Montreal, PQ, Canada
[2] K N Toosi Univ Technol, Elect Engn Fac, Tehran, Iran
[3] K N Toosi Univ Technol, Dept Biomed Engn, Tehran 1631714191, Iran
[4] Inst Univ Geriatrie Montreal, Ctr Rech, Montreal, PQ H3C 1B4, Canada
关键词
Estimation; Bayes methods; System identification; Mathematical models; Blood pressure; Biomedical monitoring; Monitoring; Beat-to-beat blood pressure measurement; oscillometry; recursive Bayesian estimation; system identification; CARDIOVASCULAR SIGNALS; STATISTICAL-MODEL;
D O I
10.1109/TBME.2024.3465663
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Our study aims to advance noninvasive blood pressure (BP) monitoring through the introduction of innovative beat-to-beat oscillometric BP estimation methods. We aim to overcome current device limitations by delivering continuous and accurate BP estimates, utilizing physiologically based mathematical models. Methods: We developed novel beat-to-beat oscillometric BP estimation methods based on physiologically grounded mathematical models of intra-arterial BP and the arterial system effect. Our approach includes a recursive Bayesian method for parameter estimation and a new system identification technique to refine initial parameter estimates. We tested our methods through simulations and real-world experiments involving 10 individuals. Results: Mean errors for systolic and diastolic BP were as low as -1.26 mmHg and 2.03 mmHg, respectively, with standard deviations of errors at 5.95 mmHg and 4.16 mmHg. Furthermore, our methods enabled the estimation of additional cardiovascular parameters such as heart rate, respiration rate, and mean arterial pressure. Conclusion: Our novel beat-to-beat oscillometric BP estimation methods offer a significant advancement in noninvasive BP monitoring technology, addressing the limitations of current devices by providing continuous beat-to-beat BP estimates. Significance: Our approach represents a promising direction for improving the reliability and comprehensiveness of cardiovascular parameter estimation in noninvasive BP monitoring devices, facilitating more effective patient care and monitoring.
引用
收藏
页码:619 / 629
页数:11
相关论文
共 50 条
  • [21] BEAT-TO-BEAT BLOOD-PRESSURE RESPONSE IN ASYMPTOMATIC IDDM SUBJECTS
    GOLDSTEIN, IB
    NALIBOFF, BD
    SHAPIRO, D
    FRANK, HJL
    DIABETES CARE, 1988, 11 (10) : 774 - 779
  • [22] Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver
    Goldstein, David S.
    Cheshire, William P., Jr.
    CLINICAL AUTONOMIC RESEARCH, 2017, 27 (06) : 361 - 367
  • [23] Beat-to-Beat Blood Pressure Variation and Cardiovascular Organ Injuries in Hypertension
    Ishimitsu, Toshihiko
    CIRCULATION JOURNAL, 2014, 78 (09) : 2162 - 2163
  • [24] Effect of peripheral vasoconstriction on the beat-to-beat measurement of finger blood pressure
    Raamat, R
    Talts, J
    Jagomägi, K
    Kingisepp, PH
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2223 - 2226
  • [25] Reduced resting beat-to-beat blood pressure variability in multiple sclerosis
    Trotter, Claire
    Young, Ben
    Huang, Mu
    Allen, Dustin
    Fade, Paul
    Davis, Scott
    FASEB JOURNAL, 2021, 35
  • [26] ADOPTION OF CONTINUOUS BEAT-TO-BEAT NOCTURNAL BLOOD PRESSURE MEASUREMENT IN AMBULATORY BLOOD PRESSURE MONITORING
    Estrada, Sebastian
    Kwon, Younghoon
    Baruch, Martin
    Harrison, Elizabeth
    Williams, Ronald
    Cho, Yeilim
    Gerdt, David
    Bonner, Heather
    Mazimba, Sula
    Berry, Richard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1893 - 1893
  • [27] Beat-to-Beat Blood Pressure Variations While Standing are Associated with Postural Changes in Blood Pressure
    Goh, C. H.
    Ng, S. C.
    Tan, M. P.
    INTERNATIONAL CONFERENCE FOR INNOVATION IN BIOMEDICAL ENGINEERING AND LIFE SCIENCES, ICIBEL2015, 2016, 56 : 44 - 48
  • [28] Blood pressure measurements in research: suitability of auscultatory, beat-to-beat, and ambulatory blood pressure measurements
    Carlson, Debra J.
    Dieberg, Gudrun
    Mcfarlane, James R.
    Smart, Neil A.
    BLOOD PRESSURE MONITORING, 2019, 24 (01) : 18 - 23
  • [29] Deep Learning Model with Individualized Fine-tuning for Dynamic and Beat-to-Beat Blood Pressure Estimation
    Hong, Jingyuan
    Gao, Jiasheng
    Liu, Qing
    Zhang, Yuanting
    Zheng, Yali
    2021 IEEE 17TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2021,
  • [30] A Wireless Wearable Sensor Patch for the Real-Time Estimation of Continuous Beat-to-Beat Blood Pressure
    Qiu, Chunkai
    Wu, Taiyang
    Redoute, Jean-Michel
    Yuce, Mehmet Rasit
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6842 - 6845