3-D motion tracking and vascular strain imaging using bistatic dual aperture ultrasound acquisitions

被引:0
|
作者
de Hoop, Hein [1 ]
Maas, Esther [1 ,2 ]
Muller, Jan-Willem [1 ,2 ]
Schwab, Hans-Martin [1 ]
Lopata, Richard [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Photoacoust & Ultrasound Lab Eindhoven, Eindhoven, Netherlands
[2] Catharina Hosp, Dept Vasc Surg, Eindhoven, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2025年 / 70卷 / 04期
关键词
multi-aperture; abdominal aorta; motion tracking; strain imaging; elastography; bistatic; 3D; SPECKLE TRACKING; MECHANICAL-PROPERTIES; DISPLACEMENT;
D O I
10.1088/1361-6560/ad9db2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. This study demonstrates high volume rate bistatic 3-D vascular strain imaging, to overcome well-known challenges caused by the anisotropic resolution and contrast inherent to ultrasound imaging. Approach. Using two synchronized 32 x 32 element matrix arrays (3.5 MHz), coherent 3-D ultrasound images of ex vivo porcine aortas were acquired at 90 Hz during pulsation in a mock circulation loop. The image data of interleaved transmissions were coherently compounded on one densely sampled Cartesian grid to estimate frame-to-frame displacements using 3-D block matching. The radial displacement components were projected onto mesh nodes of the aortic wall, after which local circumferential and radial strain estimates were calculated with a 3-D least squares strain estimator. Main results. The additional reflection content and high-resolution phase information along the axis of the second transducer added more distinctive features for block matching, resulting in an increased coverage of high correlation values and more accurate lateral displacements. Compared to single array results, the mean motion tracking error for one inflation cycle was reduced by a factor 5-8 and circumferential elastographic signal-to-noise ratio increased by 5-10 dB. Radial strain remains difficult to estimate at the transmit frequency used at these imaging depths, but may benefit from more research into strain regularization and sub-pixel interpolation techniques. Significance. These results suggest that multi-aperture ultrasound acquisition sequences can advance the field of vascular strain imaging and elastography by addressing challenges related to estimating local-scale deformation on an acquisition level. Future research into 3-D aberration correction and probe localization techniques is important to extend the method's applicability towards in vivo use and for a wider range of applications.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Bistatic ISAR Imaging Incorporating Interferometric 3-D Imaging Technique
    Ma, Changzheng
    Yeo, Tat Soon
    Guo, Qiang
    Wei, Pingjun
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2012, 50 (10): : 3859 - 3867
  • [22] Deformable Mesh based Motion Tracking for Ultrasound Strain Imaging
    Jiang, Zhiqiang
    Liu, Dong C.
    APCMBE 2008: 7TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2008, 19 : 293 - +
  • [23] Efficient Two-Pass 3-D Speckle Tracking for Ultrasound Imaging
    Jeng, Geng-Shi
    Zontak, Maria
    Parajuli, Nripesh
    Lu, Allen
    Ta, Kevinminh
    Sinusas, Albert J.
    Duncan, James S.
    O'Donnell, Matthew
    IEEE ACCESS, 2018, 6 : 17415 - 17428
  • [24] Real-time transrectal 3-D ultrasound using synthetic aperture
    Yen, Jesse T.
    Seo, Chi Hyung
    Daher, Nadim M.
    MEDICAL IMAGING 2006: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2006, 6147
  • [25] 3-D ultrasound imaging: A review
    Fenster, A
    Downey, DB
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06): : 41 - 51
  • [26] 3-D Motion Correction for Volumetric Super-Resolution Ultrasound Imaging
    Harput, Sevan
    Christensen-Jeffries, Kirsten
    Brown, Jemma
    Zhu, Jiaqi
    Zhang, Ge
    Eckersley, Robert J.
    Dunsby, Chris
    Tang, Meng-Xing
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [27] 3-D Ultrasound Imaging Using Helicoid Array Transducers
    Kim, Young-Joong
    Wolf, Patrick D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (03) : 697 - 706
  • [28] Tracking 3-D motion with nanometer accuracy
    Mizutani, Kana
    Nishizaka, Takayuki
    Okada, Kaoru
    Masaike, Tomoko
    BIOPHYSICAL JOURNAL, 2007, : 657A - 657A
  • [29] Quantification of thyroid volume using 3-D ultrasound imaging
    Kollorz, Eva N. K.
    Hahn, Dieter A.
    Linke, Rainer
    Goecke, Tamme W.
    Hornegger, Joachim
    Kuwert, Torsten
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (04) : 457 - 466
  • [30] TRACKING FACILITATES 3-D MOTION ESTIMATION
    FERMULLER, C
    ALOIMONOS, Y
    BIOLOGICAL CYBERNETICS, 1992, 67 (03) : 259 - 268