3-D motion tracking and vascular strain imaging using bistatic dual aperture ultrasound acquisitions

被引:0
|
作者
de Hoop, Hein [1 ]
Maas, Esther [1 ,2 ]
Muller, Jan-Willem [1 ,2 ]
Schwab, Hans-Martin [1 ]
Lopata, Richard [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Photoacoust & Ultrasound Lab Eindhoven, Eindhoven, Netherlands
[2] Catharina Hosp, Dept Vasc Surg, Eindhoven, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2025年 / 70卷 / 04期
关键词
multi-aperture; abdominal aorta; motion tracking; strain imaging; elastography; bistatic; 3D; SPECKLE TRACKING; MECHANICAL-PROPERTIES; DISPLACEMENT;
D O I
10.1088/1361-6560/ad9db2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. This study demonstrates high volume rate bistatic 3-D vascular strain imaging, to overcome well-known challenges caused by the anisotropic resolution and contrast inherent to ultrasound imaging. Approach. Using two synchronized 32 x 32 element matrix arrays (3.5 MHz), coherent 3-D ultrasound images of ex vivo porcine aortas were acquired at 90 Hz during pulsation in a mock circulation loop. The image data of interleaved transmissions were coherently compounded on one densely sampled Cartesian grid to estimate frame-to-frame displacements using 3-D block matching. The radial displacement components were projected onto mesh nodes of the aortic wall, after which local circumferential and radial strain estimates were calculated with a 3-D least squares strain estimator. Main results. The additional reflection content and high-resolution phase information along the axis of the second transducer added more distinctive features for block matching, resulting in an increased coverage of high correlation values and more accurate lateral displacements. Compared to single array results, the mean motion tracking error for one inflation cycle was reduced by a factor 5-8 and circumferential elastographic signal-to-noise ratio increased by 5-10 dB. Radial strain remains difficult to estimate at the transmit frequency used at these imaging depths, but may benefit from more research into strain regularization and sub-pixel interpolation techniques. Significance. These results suggest that multi-aperture ultrasound acquisition sequences can advance the field of vascular strain imaging and elastography by addressing challenges related to estimating local-scale deformation on an acquisition level. Future research into 3-D aberration correction and probe localization techniques is important to extend the method's applicability towards in vivo use and for a wider range of applications.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] 3-D vascular ultrasound imaging
    Fenster, A
    Lee, D
    Downey, D
    WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 559 - 561
  • [2] Rectilinear 3-D ultrasound imaging using synthetic aperture techniques
    Daher, NM
    Yen, JT
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 1270 - 1273
  • [3] Coherent Bistatic 3-D Ultrasound Imaging Using Two Sparse Matrix Arrays
    De Hoop, Hein
    Vermeulen, Marieke
    Schwab, Hans-Martin
    Lopata, Richard G. P.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (03) : 182 - 196
  • [4] Advances in 3-D vascular ultrasound imaging
    Fenster, Aaron
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 43 : 83 - 84
  • [5] SEPARABLE BEAMFORMING FOR 3-D SYNTHETIC APERTURE ULTRASOUND IMAGING
    Yang, Ming
    Sampson, Richard
    Wenisch, Thomas F.
    Chakrabarti, Chaitali
    2013 IEEE WORKSHOP ON SIGNAL PROCESSING SYSTEMS (SIPS), 2013, : 207 - 212
  • [6] 2-D army for 3-D ultrasound imaging using synthetic aperture techniques
    Daher, NM
    Yen, JT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (05) : 912 - 924
  • [7] Linear Tracking for 3-D Medical Ultrasound Imaging
    Huang, Qing-Hua
    Yang, Zhao
    Hu, Wei
    Jin, Lian-Wen
    Wei, Gang
    Li, Xuelong
    IEEE TRANSACTIONS ON CYBERNETICS, 2013, 43 (06) : 1747 - 1754
  • [8] A 3-D REGION-GROWING MOTION-TRACKING METHOD FOR ULTRASOUND ELASTICITY IMAGING
    Wang, Yuqi
    Jiang, Jingfeng
    Hall, Timothy J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (08): : 1638 - 1653
  • [9] In vivo bistatic dual-aperture ultrasound imaging and elastography of the abdominal aorta
    van Hal, Vera H. J.
    de Hoop, Hein
    van Sambeek, Marc R. H. M.
    Schwab, Hans-Martin
    Lopata, Richard G. P.
    FRONTIERS IN PHYSIOLOGY, 2024, 15
  • [10] Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming
    Lockwood, GR
    Talman, JR
    Brunke, SS
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) : 980 - 988