Hybrid Control Strategy for DC Microgrid Against False Data Injection Attacks and Sensor Faults Based on Lagrange Extrapolation and Voltage Observer

被引:0
|
作者
Jo, Seong-Bae [1 ]
Tran, Dat Thanh [1 ]
Nguyen, Hieu Xuan [1 ]
Kim, Myungbok [2 ]
Kim, Kyeong-Hwa [1 ]
机构
[1] Seoul Natl Univ Sci & Technol, Res Ctr Elect & Informat Technol, Dept Elect & Informat Engn, 232 Gongneung-ro, Seoul 01811, South Korea
[2] Korea Inst Ind Technol, Purpose Built Mobil Grp, 6 Choemdan gwagiro 208-gil, Gwangju 61012, South Korea
来源
ELECTRONICS | 2025年 / 14卷 / 06期
基金
新加坡国家研究基金会;
关键词
distributed DC microgrid; false data injection attack; hybrid control strategy; Lagrange extrapolation; sensor fault; DISTRIBUTED SECONDARY CONTROL; COMMUNICATION; RESTORATION; IMPROVE; ENERGY;
D O I
10.3390/electronics14061087
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this study, to enhance the system reliability under false data injection (FDI) attacks and DC-link voltage (DCLV) sensor failures, a hybrid control strategy for a DC microgrid (DCMG) based on the Lagrange extrapolation and voltage observer is proposed. Under normal conditions without FDI attacks or DCLV sensor failures, the DCMG system works in a distributed control scheme. To enhance the reliability of the system under the DCLV sensor failure or FDI attack, the DCMG system utilizes a hybrid control strategy that combines distributed control with decentralized control. The hybrid control strategy is achieved by the proposed detection algorithms for FDI attacks and DCLV sensor failures. The detection of FDI attacks is accomplished by comparing the predicted secondary controller output based on the Lagrange extrapolation with the actual one. When a power agent detects an FDI attack, its control mode is switched to decentralized control by using the proposed hybrid control strategy. The DCLV sensor failure detection algorithm to enhance system reliability against DCLV sensor failures is achieved by comparing the estimated DCLV with the measured one from the voltage observer. Upon detecting a DCLV sensor failure, the operation of the power agent is switched to the current control mode to sustain the system operation even under DCLV sensor failures. The proposed detection algorithms are simple, effective, and precise, operating without mutual interference that deteriorates the detection accuracy. Simulation and experiments are carried out under various uncertain test conditions to validate the reliability and effectiveness of the proposed control strategy.
引用
收藏
页数:25
相关论文
共 50 条
  • [31] Detection and Defense Method Against False Data Injection Attacks for Distributed Load Frequency Control System in Microgrid
    Zhixun Zhang
    Jianqiang Hu
    Jianquan Lu
    Jie Yu
    Jinde Cao
    Ardak Kashkynbayev
    Journal of Modern Power Systems and Clean Energy, 2024, 12 (03) : 913 - 924
  • [32] Resilient Event-Driven Distributed Control for DC Microgrids Against False Data Injection Attacks
    Annavaram, Devakumar
    Mishra, Sukumar
    Pullaguram, Deepak
    IEEE TRANSACTIONS ON SMART GRID, 2024, 15 (06) : 5358 - 5372
  • [33] Distributed fault-tolerant secondary control for DC microgrids against false data injection attacks
    Xie, Zongkui
    Wu, Zhongqiang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 144
  • [34] Sliding mode control of DC microgrid under false data injection attack
    Lou Q.-K.
    Chen B.
    Ding M.
    Niu Y.-G.
    Kongzhi yu Juece/Control and Decision, 2022, 37 (12): : 3207 - 3214
  • [35] A Data-Driven Based Voltage Control Strategy for DC-DC Converters: Application to DC Microgrid
    Rouzbehi, Kumars
    Miranian, Arash
    Manuel Escano, Juan
    Rakhshani, Elyas
    Shariati, Negin
    Pouresmaeil, Edris
    ELECTRONICS, 2019, 8 (05):
  • [36] Safeguard Vehicle Platooning Based on Resilient Control Against False Data Injection Attacks
    Zhao, Chengcheng
    Ma, Ruijie
    Wang, Mengzhi
    Xu, Jinming
    Cai, Lin
    IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2024, 25 (11) : 17023 - 17037
  • [37] Control strategy of hybrid energy storage systems in DC microgrid based on voltage droop method
    College of Electrical and Power Engineering, Taiyuan University of Technology, Taiyuan
    Shanxi Province
    030024, China
    Dianwang Jishu, 4 (892-898):
  • [38] Secure Control Against Multiplicative and Additive False Data Injection Attacks
    Zhu, Hongming
    Xu, Lezhong
    Bao, Zeyu
    Liu, Yifan
    Yin, Liyuan
    Yao, Weiran
    Wu, Chengwei
    Wu, Ligang
    IEEE Transactions on Industrial Cyber-Physical Systems, 2023, 1 : 92 - 100
  • [39] Optimal Protection Strategy Against False Data Injection Attacks in Power Systems
    Liu, Xuan
    Li, Zhiyi
    Li, Zuyi
    IEEE TRANSACTIONS ON SMART GRID, 2017, 8 (04) : 1802 - 1810
  • [40] Voltage stability control strategy of a DC microgrid based on a virtual DC machine
    Liu Z.
    Liu Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (04): : 62 - 71