Statistical analysis of absolute photopeak efficiency of clover HPGe detectors

被引:0
|
作者
Dey, P. [1 ]
Palit, R. [1 ]
Das, Biswajit [1 ]
Kundu, A. [1 ]
Malik, Vishal [1 ]
机构
[1] Tata Inst Fundamental Res, Dept Nucl & Atom Phys, Mumbai 400005, India
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2025年 / 1072卷
关键词
Absolute photopeak efficiency; y-ray detectors; Machine learning method; Bayesian analysis; Markov chain Monte Carlo method; NUCLEAR-DATA SHEETS; GE(LI) DETECTOR; P VALUE;
D O I
10.1016/j.nima.2024.170129
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The variation of absolute photopeak efficiency of an array of clover HPGe detectors as a function of y-ray energy has been obtained using statistical model analysis. Machine learning technique has been implemented for determining the energy-dependent polynomial of photopeak efficiency. The distribution of parameters of the best-fit model has been deduced by incorporating Markov chain Monte Carlo method working with the basic framework of Bayesian analysis which also provides the correlation between the parameters. This method has the advantage of calculating the posterior probability distribution by maximizing the likelihood function of the experimental data over standard least-squares method. Excellent agreement among the results procured from machine learning, Markov chain Monte Carlo, and least-squares method has been achieved and the correct prediction of the nature of the variation extrapolation region as well as interpolation region has been discussed.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] PHOTOPEAK AND DOUBLE-ESCAPE PEAK-CALCULATED EFFICIENCY AND COAXIAL GE(LI) DETECTORS
    AUBIN, G
    BARRETTE, J
    BARRETTE, M
    MONARO, S
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1969, 14 (01): : 18 - &
  • [42] Development of an array of fourteen HPGe detectors having 70% relative efficiency each
    Leonard, D. S.
    Hahn, K., I
    Kang, W. G.
    Kazalov, V
    Kim, G. W.
    Kim, Y. D.
    Lee, E. K.
    Lee, M. H.
    Park, S. Y.
    Sala, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 989
  • [43] Efficiency simulation of HPGe and Si(Li) detectors in γ- and X-ray spectroscopy
    Karamanis, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 282 - 285
  • [44] MCNP5 modelling of HPGe detectors for efficiency evaluation in -ray spectrometry
    Maurotto, A.
    Rizzo, S.
    Tomarchio, E.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2009, 164 (5-6): : 302 - 306
  • [45] Determination of detection efficiency curves of HPGe detectors on radioactivity measurement of volume samples
    Saegusa, J
    Kawasaki, K
    Mihara, A
    Ito, M
    Yoshida, M
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (06) : 1383 - 1390
  • [46] A SIMPLIFIED COMPUTER-PROGRAM FOR HPGE DETECTOR ABSOLUTE PEAK EFFICIENCY CALIBRATION
    WANG, TK
    KANG, LJ
    CHEN, TY
    RADIATION PHYSICS AND CHEMISTRY, 1993, 42 (4-6): : 1039 - 1042
  • [47] HPGE DETECTOR ABSOLUTE-PEAK-EFFICIENCY CALIBRATION BY USING THE ESOLAN PROGRAM
    WANG, TK
    MAR, WY
    YING, TH
    LIAO, CH
    TSENG, CL
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (09) : 933 - 944
  • [48] Improvement of HPGe Detectors Timing Using Pulse Shape Analysis
    Crespi, F. C. L.
    Vandone, V.
    Brambilla, S.
    Camera, F.
    Million, B.
    Riboldi, S.
    Wieland, O.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2121 - +
  • [49] HPGe detectors timing using pulse shape analysis techniques
    Crespi, F. C. L.
    Vandone, V.
    Brambilla, S.
    Camera, F.
    Million, B.
    Riboldi, S.
    Wieland, O.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 620 (2-3): : 299 - 304
  • [50] ABSOLUTE PHOTOPEAK EFFICIENCY VALUES FOR PLANAR GE-DETECTORS IN THE GAMMA-RAY ENERGY REGION 30-600-KEV WITH SELF-ABSORPTION IN THE SOURCE
    RIEPPO, R
    NUCLEAR INSTRUMENTS & METHODS, 1981, 179 (01): : 155 - 158