Effectiveness of the Intrauterine Balloon Tamponade Compared With an Intrauterine, Vacuum-Induced, Hemorrhage-Control Device for Postpartum Hemorrhage

被引:0
|
作者
Shields, Laurence E. [1 ]
Klein, Catherine
Torti, Jennie
Foster, Mindy
Cook, Curtis
机构
[1] Marian Reg Med Ctr, Santa Maria, CA 93454 USA
来源
OBSTETRICS AND GYNECOLOGY | 2025年 / 145卷 / 01期
关键词
D O I
10.1097/AOG.0000000000005770
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To compare intrauterine balloon tamponade and vacuum-induced hemorrhage-control devices in a multicenter hospital system using a standardized three-stage postpartum hemorrhage response algorithm. Methods: As part of a quality improvement project, data were prospectively collected through ongoing detailed hemorrhage case audits from 65 facilities from August 2022 to February 2024. Postpartum hemorrhage-control devices are recommended for stage 2 or 3 of the postpartum hemorrhage algorithm. The primary outcomes were 1) quantitative blood loss after device placement, 2) rate of packed red blood cell (RBC) transfusion, 3) use of 3 units of packed RBCs or more, and 4) device failure. Results: During the 17-month observation period, there were 123,292 deliveries, and postpartum hemorrhage occurred in 5,931 (4.8%). Postpartum hemorrhage-control devices were used in 11.2% of cases (666 total, intrauterine balloon tamponade n=300, and vacuum-induced hemorrhage control n=366). For intrauterine balloon tamponade and vacuum-induced hemorrhage-control devices, quantitative blood loss (median and interquartile range) after device placement was similar at 194 (67-440) mL and 240 (113-528) mL ( P =.40), respectively, as was the rate of any packed RBC transfusion (59.7% vs 50.0%, P =.08), transfusion of 3 packed RBC units or more (27.0% vs 24.9%, P =.53), and device failure (7.7% vs 8.5%, P =.70). Placement of either device at a quantitative blood loss between 1,000 and 1,499 mL compared with 1,500 mL or more resulted in significantly lower rates of packed RBC transfusion (39.1% vs 70.3%, P <.001), transfusion of 3 or more packed RBC units (13.7 vs 38.1%, P <.001), and device failure (3.4% vs 12.9%, P <.001). Conclusion: Transfusion and blood loss after device placement were similar with both hemorrhage-control devices. Earlier hemorrhage-control device placement reduced device failure and the need for transfusion.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [31] Predictors of Failed Intrauterine Balloon Tamponade in the Management of Severe Postpartum Hemorrhage
    Liu, Congcong
    Gao, Jinsong
    Liu, Juntao
    Wang, Xietong
    He, Jing
    Sun, Jingxia
    Liu, Xiaowei
    Liao, Shixiu
    FRONTIERS IN MEDICINE, 2021, 8
  • [32] Differential Effects of Intrauterine Balloon Tamponade Indications on Postpartum Hemorrhage Outcomes
    Xu, Chuangchuang
    Chen, Yiyao
    Wen, Lin
    Chi, Xiaolei
    Chen, Xinliang
    FRONTIERS IN MEDICINE, 2022, 9
  • [33] Intrauterine pressure measurements after balloon tamponade for postpartum hemorrhage.
    Dabelea, Victor
    Schultze, Peter M.
    McDuffie, Robert S.
    REPRODUCTIVE SCIENCES, 2008, 15 (02) : 252A - 252A
  • [34] The association between intrauterine balloon tamponade duration and postpartum hemorrhage outcomes
    Einerson, Brett D.
    Son, Moeun
    Schneider, Patrick
    Fields, Ian
    Miller, Emily S.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2017, 216 (03)
  • [35] Timely use of Bakri intrauterine balloon tamponade contributes to the effectiveness in controlling severe postpartum hemorrhage
    Hu, Yaping
    Cui, Lingjie
    Zhang, Chong
    Chen, Feifei
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2024, 27 (05)
  • [36] How I do ... an evaluation of the proper placement and effectiveness of an intrauterine tamponade balloon for postpartum hemorrhage?
    Pauchet, M.
    Berveiller, P.
    Garabedian, C.
    GYNECOLOGIE OBSTETRIQUE FERTILITE & SENOLOGIE, 2021, 49 (09): : 703 - 705
  • [37] Prognostic factors for the use of intrauterine balloon tamponade in the management of severe postpartum hemorrhage
    Kong, Choi Wah
    To, William W.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2018, 142 (01) : 48 - 53
  • [38] Profile of the Jada® System: the vacuum-induced hemorrhage control device for treating abnormal postpartum uterine bleeding and postpartum hemorrhage
    D'Alton, Mary
    Rood, Kara
    Simhan, Hyagriv
    Goffman, Dena
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (09) : 849 - 853
  • [39] Intrauterine balloon tamponade for the control of postpartum haemorrhage
    Lohano, Rajni
    Haq, Gulfishan
    Kazi, Sarah
    Sheikh, Saima
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2016, 66 (01) : 22 - 26
  • [40] Risk Factors for Intrauterine Tamponade Failure in Postpartum Hemorrhage
    Gibier, Mathilde
    Pauly, Vanessa
    Orleans, Veronica
    Fabre, Cyprien
    Boyer, Laurent
    Blanc, Julie
    OBSTETRICS AND GYNECOLOGY, 2022, 140 (03): : 439 - 446