Effectiveness of the Intrauterine Balloon Tamponade Compared With an Intrauterine, Vacuum-Induced, Hemorrhage-Control Device for Postpartum Hemorrhage

被引:0
|
作者
Shields, Laurence E. [1 ]
Klein, Catherine
Torti, Jennie
Foster, Mindy
Cook, Curtis
机构
[1] Marian Reg Med Ctr, Santa Maria, CA 93454 USA
来源
OBSTETRICS AND GYNECOLOGY | 2025年 / 145卷 / 01期
关键词
D O I
10.1097/AOG.0000000000005770
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To compare intrauterine balloon tamponade and vacuum-induced hemorrhage-control devices in a multicenter hospital system using a standardized three-stage postpartum hemorrhage response algorithm. Methods: As part of a quality improvement project, data were prospectively collected through ongoing detailed hemorrhage case audits from 65 facilities from August 2022 to February 2024. Postpartum hemorrhage-control devices are recommended for stage 2 or 3 of the postpartum hemorrhage algorithm. The primary outcomes were 1) quantitative blood loss after device placement, 2) rate of packed red blood cell (RBC) transfusion, 3) use of 3 units of packed RBCs or more, and 4) device failure. Results: During the 17-month observation period, there were 123,292 deliveries, and postpartum hemorrhage occurred in 5,931 (4.8%). Postpartum hemorrhage-control devices were used in 11.2% of cases (666 total, intrauterine balloon tamponade n=300, and vacuum-induced hemorrhage control n=366). For intrauterine balloon tamponade and vacuum-induced hemorrhage-control devices, quantitative blood loss (median and interquartile range) after device placement was similar at 194 (67-440) mL and 240 (113-528) mL ( P =.40), respectively, as was the rate of any packed RBC transfusion (59.7% vs 50.0%, P =.08), transfusion of 3 packed RBC units or more (27.0% vs 24.9%, P =.53), and device failure (7.7% vs 8.5%, P =.70). Placement of either device at a quantitative blood loss between 1,000 and 1,499 mL compared with 1,500 mL or more resulted in significantly lower rates of packed RBC transfusion (39.1% vs 70.3%, P <.001), transfusion of 3 or more packed RBC units (13.7 vs 38.1%, P <.001), and device failure (3.4% vs 12.9%, P <.001). Conclusion: Transfusion and blood loss after device placement were similar with both hemorrhage-control devices. Earlier hemorrhage-control device placement reduced device failure and the need for transfusion.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [1] Intrauterine Vacuum-Induced Hemorrhage-Control Device for Rapid Treatment of Postpartum Hemorrhage
    D'Alton, Mary E.
    Rood, Kara M.
    Smid, Marcela C.
    Simhan, Hyagriv N.
    Skupski, Daniel W.
    Subramaniam, Akila
    Gibson, Kelly S.
    Rosen, Todd
    Clark, Shannon M.
    Dudley, Donald
    Iqbal, Sara N.
    Paglia, Michael J.
    Duzyj, Christina M.
    Chien, Edward K.
    Gibbins, Karen J.
    Wine, Kathryn D.
    Bentum, Nana Ama A.
    Kominiarek, Michelle A.
    Tuuli, Methodius G.
    Goffman, Dena
    OBSTETRICS AND GYNECOLOGY, 2020, 136 (05): : 882 - 891
  • [2] Intrauterine Vacuum-Induced Hemorrhage-Control Device for Rapid Treatment of Postpartum Hemorrhage Reply
    Goffman, Dena
    D'Alton, Mary E.
    OBSTETRICS AND GYNECOLOGY, 2021, 137 (06): : 1127 - 1128
  • [3] Intrauterine Vacuum-Induced Device Compared to Uterine Balloon Tamponade in Management of Postpartum Hemorrhage.
    Levian, Candace
    Greene, Naomi
    Moran, Katherine
    Florin, Andrew
    Wong, Melissa
    Ozimek, John
    Naqvi, Mariam
    REPRODUCTIVE SCIENCES, 2024, 31 : 290A - 290A
  • [4] Intrauterine vacuum-induced tamponade versus intrauterine balloon-tamponade for postpartum hemorrhage management
    Trawick, Emma
    Watters, Amber
    Stetson, Bethany T.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2024, 230 (01) : S386 - S386
  • [5] Real-World Utilization of an Intrauterine, Vacuum-Induced, Hemorrhage-Control Device
    Goffman, Dena
    Rood, Kara M.
    Bianco, Angela
    Biggio, Joseph R.
    Dietz, Paul
    Drake, Kelly
    Heilman, Erica
    Hopkins, Maeve
    Jones, Monique De Four
    Katz, Tyler
    Martin, Courtney
    Prasad, Mona
    Smid, Marcela C.
    Wine, Kathryn D.
    Ryan, Robert
    Yong, Candice
    Carney, Patricia I.
    Simhan, Hyagriv N.
    OBSTETRICS AND GYNECOLOGY, 2023, 142 (05): : 1006 - 1016
  • [6] Real-world utilization of an intrauterine vacuum-induced hemorrhage-control device
    Goffman, Dena
    Rood, Kara M.
    Bianco, Angela
    Biggio, Joseph R., Jr.
    Dietz, Paul
    Drake, Kelly
    Heilman, Erica
    Hopkins, Maeve
    Jones, Monique De Four
    Katz, Tyler
    Martin, Courtney
    Prasad, Mona
    Smid, Marcela C.
    Wine, Kathryn
    Ryan, Robert
    Yong, Candice
    Carney, Patricia I.
    Simhan, Hyagriv
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S767 - S767
  • [7] Intrauterine vacuum-induced hemorrhage-control device for hemorrhage after myomectomy: a case report and review of the literature
    Lee, David
    Stuart, Sean
    Franco-Marx, Ylbe
    GYNECOLOGY AND PELVIC MEDICINE, 2024, 7
  • [8] Vacuum-Induced Hemorrhage Control Device versus Uterine Balloon Tamponade for Management of Postpartum Hemorrhage
    Gerber, Rachel P.
    Jones, Monique De Four
    Nimaroff, Michael
    Rochelson, Burton
    Gulersen, Moti
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2022, 226 (01) : S716 - S716
  • [9] Vacuum-Induced Hemorrhage Control versus Uterine Balloon Tamponade for Postpartum Hemorrhage
    Gulersen, Moti
    Gerber, Rachel P.
    Rochelson, Burton
    Nimaroff, Michael
    Jones, Monique D. F.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2023, 45 (04) : 267 - 272
  • [10] Intrauterine Postpartum Hemorrhage-Control Devices
    Jackson, Tracy L.
    Tuuli, Methodius G.
    OBSTETRICS AND GYNECOLOGY, 2023, 142 (05): : 1000 - 1005