共 50 条
Performance of patient-collected dried blood specimens for HIV-1 viral load testing in South Africa
被引:1
|作者:
Sahu, Maitreyi
[1
,2
]
Schaafsma, Torin
[3
]
Szpiro, Adam A.
[4
]
Van Rooyen, Heidi
[5
]
Asiimwe, Stephen
[6
]
Shahmanesh, Maryam
[7
]
Krows, Meighan L.
[2
,3
]
Sithole, Nsika
[7
]
Van Heerden, Alastair
[8
,9
]
Barnabas, Ruanne V.
[2
,10
]
DO ART Study Team
机构:
[1] Univ Washington, Dept Hlth Metr Sci, Seattle, WA 98195 USA
[2] Massachusetts Gen Hosp, Div Infect Dis, Boston, MA 02114 USA
[3] Univ Washington, Int Clin Res Ctr, Dept Global Hlth, Seattle, WA USA
[4] Univ Washington, Dept Biostat, Seattle, WA USA
[5] Human Sci Res Council, Western Cape, South Africa
[6] Integrated Community Based Initiat, Kabwohe, Uganda
[7] Africa Hlth Res Inst, Kwa Zulu, South Africa
[8] Univ Witwatersrand, Sch Clin Med, Dept Paediat, SAMRC WITS Dev Pathways Hlth Res Unit,Fac Hlth Sci, Johannesburg, Gauteng, South Africa
[9] Human Sci Res Council, Ctr Community Based Res, Kwa Zulu, South Africa
[10] Harvard Med Sch, Boston, MA USA
来源:
关键词:
dried blood spots;
HIV;
self-testing;
validation;
viral load;
IMMUNODEFICIENCY-VIRUS RNA;
ANTIRETROVIRAL TREATMENT;
SPOTS;
THERAPY;
COHORT;
UGANDA;
ASSAYS;
D O I:
10.1097/QAD.0000000000004011
中图分类号:
R392 [医学免疫学];
Q939.91 [免疫学];
学科分类号:
100102 ;
摘要:
Objective:Evaluate the clinical utility of patient-collected dried blood spots (DBS) in measuring HIV-1 viral load (VL) for monitoring antiretroviral therapy (ART) compared to provider-collected DBS and blood plasma.Design:In a randomized trial of community-based delivery of ART in South Africa, we assessed performance of: DBS specimens compared to plasma, and participant-collected vs. staff-collected DBS specimens, to measure HIV-1 VL.Methods:The bioM & eacute;rieux NucliSENS EasyQ HIV-1 v2.0 assay was used for VL measurement. From October 2017 to November 2019, we collected 996 pairs of plasma/DBS specimens from 760 participants and 315 pairs of staff-/participant-collected DBS cards from 261 participants. We assessed DBS test sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) using the WHO failure threshold of 1000 copies/ml. Log-transformed VL was compared using concordance correlation coefficients (CCC) and mean differences from linear mixed models.Results:In a population with 13% detectable VL, DBS VL compared with plasma VL had 91% [95% confidence interval (CI): 86-95] sensitivity, 99% (98-100) specificity, 94% (90-98) PPV, and 99% (98-99) NPV. We observed high agreement between staff-collected DBS VL and plasma VL (CCC: 0.94), and between participant-collected DBS VL and plasma VL (CCC: 0.92). We did not observe a statistically significant difference between participant- and staff-collected DBS VL and correlation was very high (CCC: 0.97).Conclusions:VL results from participant-collected DBS are clinically comparable with those collected by clinical staff and using blood plasma. Self-collected DBS has potential for use for ART monitoring outside the clinic.
引用
收藏
页码:2050 / 2055
页数:6
相关论文