Analyzing the image quality using a quantitative index for the robotic ultrasound probe maneuver system

被引:0
|
作者
Choi, Woohyeok [1 ]
Yoshimitsu, Kitaro [2 ]
Kobayashi, Etsuko [1 ]
Masamune, Ken [2 ]
Muragaki, Yoshihiro [2 ,3 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Precis Engn, Tokyo, Japan
[2] Tokyo Womens Med Univ, Fac Adv Techno Surg FATS, Insititue Adv Biomed Engn & Sci, Tokyo, Japan
[3] Kobe Univ, Ctr Adv Med Engn Res & Dev CAMED, Kobe, Japan
关键词
Image quality assessment; quantitative index; ultrasound probe maneuver; robotic ultrasound system; CONFIDENCE-DRIVEN CONTROL;
D O I
10.1080/01691864.2024.2415090
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This paper presents a quantitative index introduced, 'clarity,' which can address both the ultrasound probe's brightness and full contact states to indicate ultrasound image quality for the robotic ultrasound system. Furthermore, it evaluates its performance through an experiment, a comparative analysis, and a questionnaire. The index is calculated based on pixel statistics within the predefined region of interest. Experimental validation is conducted by implementing a robotic ultrasound system and performing experiments using two phantoms. Notably, the Results demonstrate the distinction of the visible difference in ultrasound images but also show that it is hard to classify the tiny difference. Additionally, a questionnaire was carried out to ask about the recognition of good image quality. The opinions are the same trends and patterns. The 53.4 clarity value was determined from the answers as the boundary between good and bad-quality images. The experiment results, and questionnaire findings suggest that the proposed clarity index could be a reliable tool for evaluating ultrasound image quality in robotic systems, offering insights for improving diagnostic accuracy and efficiency. This research provides a clear framework for assessing ultrasound image quality in robotic applications, paving the way for advancements in the efficacy and precision of ultrasound imaging techniques.
引用
收藏
页码:1743 / 1757
页数:15
相关论文
共 50 条
  • [31] Ultrasound Field Measuring Using Hydrophone for Quantitative Evaluation of Medical Ultrasonic Probe
    Yu, W. J.
    Noh, S. C.
    Park, M. K.
    Min, H. K.
    Park, J. H.
    Choi, H. H.
    SAS 2009 - IEEE SENSORS APPLICATIONS SYMPOSIUM, PROCEEDINGS, 2009, : 70 - 73
  • [32] Safe control of ultrasound probe on abdomen by pulling cables for robotic tele-echography system
    Masuda, K
    Vilchis, A
    Troccaz, J
    Cinquin, P
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3676 - 3679
  • [33] In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system
    Bell, Muyinatu A. Lediju
    Sen, H. Tutkun
    Iordachita, Iulian
    Kazanzides, Peter
    Wong, John
    JOURNAL OF MEDICAL IMAGING, 2014, 1 (02)
  • [34] QUANTITATIVE ELECTRONIC ANALYSIS OF CHROMOSOME AUTORADIOGRAPHS USING A TELEVISION IMAGE ANALYZING COMPUTER
    STENGELR.S
    GUNDLACH, H
    ZANG, KD
    EXPERIMENTAL CELL RESEARCH, 1974, 87 (02) : 313 - 325
  • [35] Using Quantitative Ultrasound to Evaluate Postmortem Adult Bone Quality
    Taylor, Alex
    Ruth, Aidan
    FASEB JOURNAL, 2021, 35
  • [36] Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis
    Mesquita, Daniela P.
    Luis Amaral, A.
    Ferreira, Eugenio C.
    CHEMICAL ENGINEERING JOURNAL, 2016, 285 : 349 - 357
  • [37] Image-Guided Navigation of a Robotic Ultrasound Probe for Autonomous Spinal Sonography Using a Shadow-Aware Dual-Agent Framework
    Li, Keyu
    Xu, Yangxin
    Wang, Jian
    Ni, Dong
    Liu, Li
    Meng, Max Q-H
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2022, 4 (01): : 130 - 144
  • [38] RECOGNITION OF THE RETROGRADE REACTION IN MOTONEURONS USING AN IMAGE ANALYZING SYSTEM
    RAUCH, F
    SCHLEICHER, A
    ZILLES, K
    JOURNAL OF NEUROSCIENCE METHODS, 1989, 30 (03) : 255 - 262
  • [39] Quantitative Image Quality Measurements of a Digital Breast Tomosynthesis System
    Olgar, T.
    Kahn, T.
    Gosch, D.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (12): : 1188 - 1194
  • [40] A QUANTITATIVE STUDY OF THE CEREBRAL-CORTEX IN ALZHEIMERS-DISEASE AND SENILE DEMENTIA USING AN AUTOMATIC IMAGE ANALYZING SYSTEM
    SAUER, B
    DIETL, HW
    KRETSCHMANN, HJ
    MEHRAEIN, P
    JOURNAL FUR HIRNFORSCHUNG, 1986, 27 (06): : 695 - 702