Analyzing the image quality using a quantitative index for the robotic ultrasound probe maneuver system

被引:0
|
作者
Choi, Woohyeok [1 ]
Yoshimitsu, Kitaro [2 ]
Kobayashi, Etsuko [1 ]
Masamune, Ken [2 ]
Muragaki, Yoshihiro [2 ,3 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Precis Engn, Tokyo, Japan
[2] Tokyo Womens Med Univ, Fac Adv Techno Surg FATS, Insititue Adv Biomed Engn & Sci, Tokyo, Japan
[3] Kobe Univ, Ctr Adv Med Engn Res & Dev CAMED, Kobe, Japan
关键词
Image quality assessment; quantitative index; ultrasound probe maneuver; robotic ultrasound system; CONFIDENCE-DRIVEN CONTROL;
D O I
10.1080/01691864.2024.2415090
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This paper presents a quantitative index introduced, 'clarity,' which can address both the ultrasound probe's brightness and full contact states to indicate ultrasound image quality for the robotic ultrasound system. Furthermore, it evaluates its performance through an experiment, a comparative analysis, and a questionnaire. The index is calculated based on pixel statistics within the predefined region of interest. Experimental validation is conducted by implementing a robotic ultrasound system and performing experiments using two phantoms. Notably, the Results demonstrate the distinction of the visible difference in ultrasound images but also show that it is hard to classify the tiny difference. Additionally, a questionnaire was carried out to ask about the recognition of good image quality. The opinions are the same trends and patterns. The 53.4 clarity value was determined from the answers as the boundary between good and bad-quality images. The experiment results, and questionnaire findings suggest that the proposed clarity index could be a reliable tool for evaluating ultrasound image quality in robotic systems, offering insights for improving diagnostic accuracy and efficiency. This research provides a clear framework for assessing ultrasound image quality in robotic applications, paving the way for advancements in the efficacy and precision of ultrasound imaging techniques.
引用
收藏
页码:1743 / 1757
页数:15
相关论文
共 50 条
  • [1] Bone registration using a robotic ultrasound probe
    Torres, Pedro M. B.
    Goncalves, Paulo J. S.
    Martins, Jorge M. M.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING: VIPIMAGE 2011, 2012, : 79 - 83
  • [2] Evaluation of the quality of ultrasound image compression for a robotic tele-echographic system
    Delgorge, C
    Rosenberger, C
    Poisson, G
    Vieyres, P
    COMPUTERS IN CARDIOLOGY 2005, VOL 32, 2005, 32 : 775 - 778
  • [3] Comparative Quantitative Analysis of Robotic Ultrasound Image Calibration Methods
    Li, Ruixuan
    Cai, Yuyu
    Niu, Kenan
    Vander Poorten, Emmanuel
    2021 20TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS (ICAR), 2021, : 511 - 516
  • [4] Medical Ultrasound Image Quality Assessment for Autonomous Robotic Screening
    Song, Yuxin
    Zhong, Zhaoming
    Zhao, Baoliang
    Zhang, Peng
    Wang, Qiong
    Wang, Ziwen
    Yao, Liang
    Lv, Faqin
    Hu, Ying
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (03) : 6290 - 6296
  • [5] A probe pulling system for prostate ultrasound image acquisition
    Xiao, Di
    Liu, Feng
    Shao, Wei
    Wu, Ruoyun
    Mohan, Preeti
    Ho, Henry
    Li, Deli
    Ng, Wan Sing
    Cheng, Christopher
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S134 - S135
  • [6] Deep Kernel and Image Quality Estimators for Optimizing Robotic Ultrasound Controller using Bayesian Optimization
    Raina, Deepak
    Chandrashekhara, S. H.
    Voyles, Richard
    Wachs, Juan
    Saha, Subir Kumar
    2023 INTERNATIONAL SYMPOSIUM ON MEDICAL ROBOTICS, ISMR, 2023,
  • [7] A PROBE SYSTEM FOR ANALYZING TRANSMISSION AND PLAYBACK QUALITY OF ONLINE VIDEOS
    Wu, Di
    Jin, Yuehui
    Yang, Tan
    2014 IEEE 3RD INTERNATIONAL CONFERENCE ON CLOUD COMPUTING AND INTELLIGENCE SYSTEMS (CCIS), 2014, : 475 - 480
  • [8] Impact of robotic ultrasound image guidance on plan quality in SBRT of the prostate
    Gerlach, Stefan
    Kuhlemann, Ivo
    Ernst, Floris
    Fuereweger, Christoph
    Schlaefer, Alexander
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1078):
  • [9] ROBOTIC PARTIAL NEPHRECTOMY USING A ROBOTIC ULTRASOUND PROBE FOR TUMOR IDENTIFICATION: INITIAL SERIES AND OUTCOMES
    Rogers, Craig
    Sukumar, Shyam
    Petros, Firas
    Trinh, Quoc-Dien
    Sammon, Jesse D.
    Menon, Mani
    JOURNAL OF ENDOUROLOGY, 2011, 25 : A304 - A304
  • [10] AUTOMATED QUANTITATIVE PATHOLOGY USING AN IMAGE ANALYZING COMPUTER (LEYTAS)
    PLOEM, JS
    VASSILAKOS, P
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1982, 112 (16) : 583 - 583