Intra-Aneurysmal High-Resolution 4D MR Flow Imaging for Hemodynamic Imaging Markers in Intracranial Aneurysm Instability

被引:0
|
作者
van Tuijl, R. J. [1 ,2 ]
den Hertog, C. S. [3 ]
Timmins, K. M. [1 ]
Velthuis, B. K. [1 ]
van Ooij, P. [4 ,5 ]
Zwanenburg, J. J. M. [2 ]
Ruigrok, Y. M. [3 ]
van der Schaaf, I. C. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Translat Neuroimaging Grp, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Univ Med Ctr Utrecht Brain Ctr, UMC Utrecht Brain Ctr, Dept Neurol & Neurosurg, Utrecht, Netherlands
[4] Amsterdam Univ Med Ctr Locat AMC, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[5] Univ Med Ctr Utrecht, Dept Pediat Cardiol, Utrecht, Netherlands
基金
欧洲研究理事会;
关键词
WALL SHEAR-STRESS; ENHANCEMENT;
D O I
10.3174/ajnr.A8380
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Prediction of aneurysm instability is crucial to guide treatment decisions and to select appropriate patients with unruptured intracranial aneurysms (IAs) for preventive treatment. High resolution four-dimensional magnetic resonance (4D MRI) flow imaging and 3D quantification of aneurysm morphology could offer insights and new imaging markers for aneurysm instability. In this cross-sectional study, we aim to identify 4D MRI flow imaging markers for aneurysm instability by relating hemodynamics in the aneurysm sac to 3D morphological proxy parameters for aneurysm instability. MATERIALS AND METHODS: In 35 patients with 37 unruptured IAs, a 3T MRA and a 7T 4D flow MRI scan was performed. Five hemodynamic parameters -peak-systolic (WSSMAX) and time-averaged wall shear stress (WSSMEAN), oscillatory shear index (OSI), mean velocity, and velocity pulsatility index (vPI)-were correlated to six 3D morphology proxy parameters of aneurysm instability -major axis length, volume, surface area (all three size parameters), flatness, shape index, and curvedness -by Pearson's correlation with 95% confidence intervals (CI). Scatterplots of hemodynamic parameters that correlated with IA size (major axis length) were created. RESULTS: WSSMAX and WSSMEAN correlated negatively with all three size parameters (strongest for WSSMEAN with volume (r = -0.70, 95% CI -0.83 to -0.49)) and OSI positively (strongest with major axis length (r = 0.87, 95% CI 0.76 to 0.93)). WSSMAX and WSSMEAN correlated positively with shape index (r = 0.61, 95% CI 0.36 to 0.78 and r = 0.49, 95% CI 0.20 to 0.70, respectively) and OSI negatively (r = 0.82, 95% CI -0.9 to -0.68). WSSMEAN and mean velocity correlated negatively with flatness (r = -0.35, 95% CI -0.61 to -0.029 and r = 0.33, 95% CI -0.59 to 0.007, respectively) and OSI positively (r = 0.54, 95% CI 0.26 to 0.74). vPI did not show any statistically significant correlation. CONCLUSIONS: Out of the five included hemodynamic parameters, WSSMAX, WSSMEAN, and OSI showed the strongest correlation with morphological 3D proxy parameters of aneurysm instability. Future studies should assess these promising new imaging marker parameters for predicting aneurysm instability in longitudinal cohorts of patients with IA.
引用
收藏
页码:1678 / 1684
页数:7
相关论文
共 50 条
  • [21] The association of intracranial atherosclerosis with cerebral small vessel disease imaging markers: a high-resolution magnetic resonance imaging study
    Kang-Li Zhu
    Zi-Yang Shang
    Bai-jun Liu
    Ying Wang
    Jing Li
    Ben-Qiang Yang
    George Ntaios
    Hui-Sheng Chen
    Scientific Reports, 13
  • [22] In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T
    Wetzel, S.
    Meckel, S.
    Frydrychowicz, A.
    Bonati, L.
    Radue, E. -W.
    Scheffler, K.
    Hennig, J.
    Markl, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (03) : 433 - 438
  • [23] 4D flow MR imaging of the portal venous system: a feasibility study in children
    Parekh, Keyur
    Markl, Michael
    Rose, Michael
    Schnell, Susanne
    Popescu, Andrada
    Rigsby, Cynthia K.
    EUROPEAN RADIOLOGY, 2017, 27 (02) : 832 - 840
  • [24] Evaluation of Left Ventricular Diastolic Function Using 4D Flow MR Imaging
    Houriez--Gombaud-Saintonge, Sophia
    Bollache, Emilie
    Soulat, Gilles
    Alattar, Youssef
    Lamy, Jerome
    Dietenbeck, Thomas
    De Cesare, Alain
    Giron, Alain
    Bouaou, Kevin
    Gencer, Umit
    Redheuil, Alban
    Mousseaux, Elie
    Chenoune, Yasmina
    Kachenoura, Nadjia
    2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2018, 45
  • [25] 4D flow MR imaging of the portal venous system: a feasibility study in children
    Keyur Parekh
    Michael Markl
    Michael Rose
    Susanne Schnell
    Andrada Popescu
    Cynthia K. Rigsby
    European Radiology, 2017, 27 : 832 - 840
  • [26] High-resolution 3D imaging of intracranial aneurysms for preoperative therapy planning
    Tomandi, BF
    Eberhardt, KE
    Hastreiter, P
    Rezk-Salama, C
    Nimsky, C
    Huk, WJ
    RADIOLOGY, 2000, 217 : 178 - 178
  • [27] High-Resolution Magnetic Resonance Imaging of Intracranial Vertebral Artery Dissecting Aneurysm for Planning of Endovascular Treatment
    Chun, Dong Hyun
    Kim, Sung Tae
    Jeong, Young Gyun
    Jeong, Hae Woong
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2015, 58 (02) : 155 - 158
  • [28] Feasibility of 4D Flow MR Imaging of the Brain with Either Cartesian y-z Radial Sampling or k-t SENSE: Comparison with 4D Flow MR Imaging using SENSE
    Sekine, Tetsuro
    Amano, Yasuo
    Takagi, Ryo
    Matsumura, Yoshio
    Murai, Yasuo
    Kumita, Shinichiro
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2014, 13 (01) : 15 - 24
  • [29] High-Resolution Vessel-Wall Imaging for Analysis of Intracranial Aneurysm Daughter- Sac Vulnerability
    Larson, Anthony S.
    Lehman, Vance T.
    MAYO CLINIC PROCEEDINGS, 2021, 96 (03) : 815 - 816
  • [30] System Performance of a 79 GHz High-Resolution 4D Imaging MIMO Radar With 1728 Virtual Channels
    Schwarz, Dominik
    Riese, Nico
    Dorsch, Ines
    Waldschmidt, Christian
    IEEE JOURNAL OF MICROWAVES, 2022, 2 (04): : 637 - 647