Intra-Aneurysmal High-Resolution 4D MR Flow Imaging for Hemodynamic Imaging Markers in Intracranial Aneurysm Instability

被引:0
|
作者
van Tuijl, R. J. [1 ,2 ]
den Hertog, C. S. [3 ]
Timmins, K. M. [1 ]
Velthuis, B. K. [1 ]
van Ooij, P. [4 ,5 ]
Zwanenburg, J. J. M. [2 ]
Ruigrok, Y. M. [3 ]
van der Schaaf, I. C. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Translat Neuroimaging Grp, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Univ Med Ctr Utrecht Brain Ctr, UMC Utrecht Brain Ctr, Dept Neurol & Neurosurg, Utrecht, Netherlands
[4] Amsterdam Univ Med Ctr Locat AMC, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[5] Univ Med Ctr Utrecht, Dept Pediat Cardiol, Utrecht, Netherlands
基金
欧洲研究理事会;
关键词
WALL SHEAR-STRESS; ENHANCEMENT;
D O I
10.3174/ajnr.A8380
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Prediction of aneurysm instability is crucial to guide treatment decisions and to select appropriate patients with unruptured intracranial aneurysms (IAs) for preventive treatment. High resolution four-dimensional magnetic resonance (4D MRI) flow imaging and 3D quantification of aneurysm morphology could offer insights and new imaging markers for aneurysm instability. In this cross-sectional study, we aim to identify 4D MRI flow imaging markers for aneurysm instability by relating hemodynamics in the aneurysm sac to 3D morphological proxy parameters for aneurysm instability. MATERIALS AND METHODS: In 35 patients with 37 unruptured IAs, a 3T MRA and a 7T 4D flow MRI scan was performed. Five hemodynamic parameters -peak-systolic (WSSMAX) and time-averaged wall shear stress (WSSMEAN), oscillatory shear index (OSI), mean velocity, and velocity pulsatility index (vPI)-were correlated to six 3D morphology proxy parameters of aneurysm instability -major axis length, volume, surface area (all three size parameters), flatness, shape index, and curvedness -by Pearson's correlation with 95% confidence intervals (CI). Scatterplots of hemodynamic parameters that correlated with IA size (major axis length) were created. RESULTS: WSSMAX and WSSMEAN correlated negatively with all three size parameters (strongest for WSSMEAN with volume (r = -0.70, 95% CI -0.83 to -0.49)) and OSI positively (strongest with major axis length (r = 0.87, 95% CI 0.76 to 0.93)). WSSMAX and WSSMEAN correlated positively with shape index (r = 0.61, 95% CI 0.36 to 0.78 and r = 0.49, 95% CI 0.20 to 0.70, respectively) and OSI negatively (r = 0.82, 95% CI -0.9 to -0.68). WSSMEAN and mean velocity correlated negatively with flatness (r = -0.35, 95% CI -0.61 to -0.029 and r = 0.33, 95% CI -0.59 to 0.007, respectively) and OSI positively (r = 0.54, 95% CI 0.26 to 0.74). vPI did not show any statistically significant correlation. CONCLUSIONS: Out of the five included hemodynamic parameters, WSSMAX, WSSMEAN, and OSI showed the strongest correlation with morphological 3D proxy parameters of aneurysm instability. Future studies should assess these promising new imaging marker parameters for predicting aneurysm instability in longitudinal cohorts of patients with IA.
引用
收藏
页码:1678 / 1684
页数:7
相关论文
共 50 条
  • [1] Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction
    Shobayashi, Yasuhiro
    Tateshima, Satoshi
    Kakizaki, Ryuichi
    Sudo, Ryo
    Tanishita, Kazuo
    Vinuela, Fernando
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 : III38 - III42
  • [2] Transluminal visualization of intra-aneurysmal blood flow with transluminal flow imaging of three-dimensional MR angiography
    Satoh, T
    NEUROLOGICAL SURGERY, 2002, 30 (11): : 1173 - 1178
  • [3] Complete Intracranial Arterial and Venous Blood Flow Evaluation with 4D Flow MR Imaging
    Hope, M. D.
    Purcell, D. D.
    Hope, T. A.
    von Morze, C.
    Vigneron, D. B.
    Alley, M. T.
    Dillon, W. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (02) : 362 - 366
  • [4] Intra-aneurysmal hemodynamics: evaluation of pCONus and pCANvas bifurcation aneurysm devices using DSA optical flow imaging
    Perez, Marta Aguilar
    Henkes, Hans
    Bouillot, Pierre
    Brina, Olivier
    Slater, Lee-Anne
    Pereira, Vitor Mendes
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (11) : 1197 - 1201
  • [5] Quality Control for 4D Flow MR Imaging
    Isoda, Haruo
    Fukuyama, Atsushi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 278 - 292
  • [6] Technical Background for 4D Flow MR Imaging
    Terada, Masaki
    Takehara, Yasuo
    Isoda, Haruo
    Wakayama, Tetsuya
    Nozaki, Atsushi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 267 - 277
  • [7] Intra-articular coils for high-resolution MR imaging of joints
    Gold, GE
    Pappas, G
    Scott, G
    Butts, KR
    Pauly, JM
    Beaulieu, CF
    RADIOLOGY, 2001, 221 : 558 - 558
  • [8] Feasibility of high-resolution MR imaging for the diagnosis of intracranial vertebrobasilar artery dissection
    Miran Han
    Nae-Jung Rim
    Jin Soo Lee
    Sun Yong Kim
    Jin Wook Choi
    European Radiology, 2014, 24 : 3017 - 3024
  • [9] Feasibility of high-resolution MR imaging for the diagnosis of intracranial vertebrobasilar artery dissection
    Han, Miran
    Rim, Nae-Jung
    Lee, Jin Soo
    Kim, Sun Yong
    Choi, Jin Wook
    EUROPEAN RADIOLOGY, 2014, 24 (12) : 3017 - 3024
  • [10] Hemodynamic Evaluation of Intracranial Aneurysm: Comparison of Computational Fluid Dynamics with 4D Flow MRI
    Misaki, Kouichi
    Futami, Kazuya
    Uno, Takehiro
    Nambu, Iku
    Yoshikawa, Akifumi
    Kamide, Tomoya
    Nakada, Mitsutoshi