Predictors of segmental lumbar lordosis following midline posterior (transforaminal) lumbar interbody fusion: Does interbody device type matter?

被引:0
|
作者
Crawford, Charles [1 ,2 ]
Epperson, Thomas [2 ]
Gum, Jeffrey [1 ,2 ]
Owens, R. Kirk [1 ,2 ]
Djurasovic, Mladen [1 ,2 ]
Glassman, Steven D. [1 ,2 ]
Carreon, Leah Y. [1 ]
机构
[1] Norton Leatherman Spine Ctr, 210 East Gray St,Suite 900, Louisville, KY 40202 USA
[2] Univ Louisville, Sch Med, Dept Orthopaed Surg, 550 S Jackson St,1st Floor ACB, Louisville, KY 40202 USA
来源
关键词
Transforaminal interbody fusion; TLIF; Interbody device; Interbody cage; Lumbar fusion; Lumbar lordosis; RESTORATION;
D O I
10.1016/j.xnsj.2022.100145
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Controversy exists regarding the ability of posterior (transforaminal) lumbar interbody fusion (PLIF/TLIF) to achieve lordosis. We hypothesized that an interbody device (IBD) designed for positioning in the anterior disc space produces greater lordosis than IBDs designed for straight-in positioning. The purpose of this study is to determine if using either an anterior-position or straight-in position IBD design were associated with successful achievement of postoperative lordosis. Methods: A consecutive series of patients undergoing a undergoing a single-level, posterior open midline (transforaminal) lumbar interbody fusion procedure for degenerative spine conditions during a time period when the two types of interbody devices were being used at surgeon discretion were identified from a multi-surgeon academic training center. Patient demographics and radiographic measures including surgical level lordosis (SLL), anterior disc height, middle disc height, posterior disc height, IBD height, and IBD insertion depth were measured on preop, immediate postop, and one-year postop standing radiographs using PACS. Group comparison and regression analysis were performed using SPSS. Results: Sixty-one patients were included (n = 37 anterior, n = 34 straight-in). Mean age was 59.8 +/- 8.7 years, 32 (52%) were female. There was no difference between IBD type (anterior vs. straight-in) for mean Pre-op SLL (19 +/- 7 degrees vs. 20 +/- 6 degrees, p = 0.7), Post-op SLL (21 +/- 5 degrees vs 21 +/- 6 degrees, p = 0.5), or Change in SLL (2 +/- 4 degrees vs. 1 +/- 5 degrees, p = 0.2). Regression analysis showed that Pre-op SLL was the only variable associated with Change in SLL (Beta = negative 0.48, p = 0.000). While the mean Change in SLL could be considered clinically insignificant, there was wide variability: from a loss of 9 to a gain of 13 degrees. Gain of lordosis >5 degrees only occurred when Pre-op SLL was < 21 degrees, and loss of lordosis > 5 degrees only occurred when Pre-op SLL was > 21 degrees. Conclusions: While group averages showed an insignificant change in segmental lordosis following a posterior (transforaminal) interbody fusion regardless of interbody device type, pre-operative lordosis was correlated with a clinically significant change in segmental lordosis. Preoperative hypolordotic discs were more likely to gain significant lordosis, while preoperative hyperlordotic discs were more likely to lose significant lordosis. Surgeon awareness of this tendency can help guide surgical planning and technique.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Biomechanical comparison of posterior lumbar interbody fusion and transforaminal lumbar interbody fusion performed at 1 and 2 levels
    Ames, CP
    Acosta, FL
    Chi, J
    Iyengar, J
    Muiru, W
    Acaroglu, E
    Puttlitz, CM
    SPINE, 2005, 30 (19) : E562 - E566
  • [32] A comparison of posterior lumbar interbody fusion and transforaminal lumbar interbody fusion: a literature review and meta-analysis
    Zhang, Qunhu
    Yuan, Zhen
    Zhou, Min
    Liu, Huan
    Xu, Yong
    Ren, Yongxin
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [33] A retrospective controlled study protocol of transforaminal lumbar interbody fusion compared with posterior lumbar interbody fusion for spondylolisthesis
    Yi, Ping
    Tang, Xiangsheng
    Yang, Feng
    Tan, Mingsheng
    MEDICINE, 2020, 99 (44) : E22878
  • [34] Transforaminal Lumbar Interbody Fusion Versus Anterior Lumbar Interbody Fusion as an Adjunct to Posterior Instrumented Correction of Degenerative Lumbar Scoliosis
    Crandall, Dennis G.
    Revella, Jan
    SPINE, 2009, 34 (20) : 2126 - 2133
  • [35] A comparison of posterior lumbar interbody fusion and transforaminal lumbar interbody fusion: a literature review and meta-analysis
    Qunhu Zhang
    Zhen Yuan
    Min Zhou
    Huan Liu
    Yong Xu
    Yongxin Ren
    BMC Musculoskeletal Disorders, 15
  • [36] Subsidence of Center or Off-Center Posterior Lumbar Interbody Fusion and Transforaminal Lumbar Interbody Fusion Cages
    Kim, Seong-Won
    Jeong, Hyun-Yong
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2024, 25 (11) : 2387 - 2396
  • [37] Comparison of posterior lumbar interbody fusion with transforaminal lumbar interbody fusion for treatment of recurrent lumbar disc herniation: A retrospective study
    Li, Liqiang
    Liu, Yueju
    Zhang, Peng
    Lei, Tao
    Li, Jie
    Shen, Yong
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2016, 44 (06) : 1424 - 1429
  • [38] Segmental lumbar sagittal correction after bilateral transforaminal lumbar interbody fusion
    Yson, Sharon C.
    Santos, Edward Rainier G.
    Sembrano, Jonathan N.
    Polly, David W., Jr.
    JOURNAL OF NEUROSURGERY-SPINE, 2012, 17 (01) : 37 - 42
  • [39] Preoperative Radiographic Prediction Tool for Early Postoperative Segmental and Lumbar Lordosis Alignment After Transforaminal Lumbar Interbody Fusion
    Porche, Ken
    Dru, Alexander
    Moor, Rachel
    Kubilis, Paul
    Vaziri, Sasha
    Hoh, Daniel J.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [40] Predictors of Spontaneous Restoration of Lumbar Lordosis after Single-Level Transforaminal Lumbar Interbody Fusion for Degenerative Lumbar Diseases
    Ohyama, Shuhei
    Aoki, Yasuchika
    Inoue, Masahiro
    Nakajima, Takayuki
    Sato, Yusuke
    Watanabe, Atsuya
    Takahashi, Hiroshi
    Kubota, Go
    Nakajima, Arata
    Saito, Junya
    Eguchi, Yawara
    Orita, Sumihisa
    Nakagawa, Koichi
    Ohtori, Seiji
    SPINE SURGERY AND RELATED RESEARCH, 2021, 5 (06): : 397 - 404