A DAQ system with low-dead-time, high-precision TDC for APD detection efficiency calibration

被引:0
|
作者
Ma, S. [1 ,2 ]
Jin, G. [1 ,2 ]
Chen, L. [3 ]
机构
[1] Univ Sci & Technol China, Sch Nucl Sci & Technol, Hefei 230026, Peoples R China
[2] Univ Sci & Technol China, State Key Lab Particle Detect & Elect, Hefei 230026, Peoples R China
[3] Lanzhou Univ, MOE Frontiers Sci Ctr Rare Isotopes, Lanzhou 730000, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2025年 / 20卷 / 01期
关键词
Data acquisition circuits; Digital electronic circuits; Detector alignment and calibration methods (lasers; sources; particle-beams); Photon detectors for UV; visible and IR photons (solid-state) (PIN diodes; APDs; Si-PMTs; G-APDs; CCDs; EBCCDs; EMCCDs; CMOS imagers; etc);
D O I
10.1088/1748-0221/20/01/T01004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Correlated photon calibration based on spontaneous parametric down-conversion (SPDC) provides a highly precise means to calibrate the detection efficiency of avalanche photodiode (APD). During the calibration process of detection efficiency via SPDC, precise measurement of the arrival time of correlated photons and accurate photon counting are essential. To achieve this goal, a acquisition (DAQ) system with low-dead-time, high-resolution Time-to-Digital Converter (TDC) designed in this paper. This TDC is designed based on tapped delay line (TDL), which is implemented on Xilinx Kintex-7 series field programmable gate array (FPGA). This TDC can accurately measure the time of arrival of input signals. Upon arrival of a photon signal, the TDC rapidly generates timestamp to record the arrival time of the photon signal. Utilizing these timestamps, time delay accurate measurements of time intervals can be achieved. The specially designed TDC input structure and encoding algorithm enable the alternating propagation and sampling of '01' and transitions on TDL. Coupled with a pipelined architecture, the TDC's dead time is close to one cycle, which is 2.33 ns in the current implementation version. The structure of mode recognition triggering ensures that the TDC can correctly calibrate time measurements and count photon counts. Experimental results show that the TDC achieves an RMS precision of better than 11.08 ps, and measurement precision is maintained over long time intervals (0-10 us). The reliability of this for photon counting has been verified through standard signal sources.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Hall probe calibration in high-precision magnetic field mapping system of superconducting cyclotron
    Xu, Manman
    Cao, Chuqing
    Fu, Yili
    Wu, Yonghong
    Wang, Xiangdong
    Su, Yongsheng
    Xi, Lin
    Liu, Yongming
    NUKLEONIKA, 2024, 69 (04) : 185 - 193
  • [42] High-precision phase detection in femtosecond timing and synchronization system for TXGLS
    Xu, Yilun
    Huang, Gang
    Doolittle, Lawrence
    Du, Qiang
    Wilcox, Russell
    Yang, Jin
    Lin, Zhenyang
    Du, Yingchao
    Yan, Lixin
    Huang, Wenhui
    Tang, Chuanxiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (06)
  • [43] A High-Precision Integrated Calibration Method for Position and Attitude of Visual-Inertial System
    Ma Keyao
    Ren Yongjie
    Lin Jiarui
    Niu Zhiyuan
    Zhu Jigui
    LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (03)
  • [44] Nonuniformity Correction and Calibration Method in the High-precision CCD Measurement and Servo Control System
    Li, Jing
    Wang, Junzheng
    Zhou, Bin
    Shen, Wei
    PROCEEDINGS OF THE 48TH IEEE CONFERENCE ON DECISION AND CONTROL, 2009 HELD JOINTLY WITH THE 2009 28TH CHINESE CONTROL CONFERENCE (CDC/CCC 2009), 2009, : 8446 - 8451
  • [45] A DIFFERENCE DETECTION SYSTEM FOR HIGH-PRECISION MEASUREMENTS OF ULTRAFAST TRANSMISSION CHANGES
    POLLAND, HJ
    ZINTH, W
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (05): : 399 - 400
  • [46] THE PULSE REACTOR - A HIGH-EFFICIENCY, HIGH-PRECISION LOW-PRESSURE MOCVD MACHINE
    VANSUCHTELEN, J
    HOGENKAMP, JEM
    VANSARK, WGJHM
    GILING, LJ
    JOURNAL OF CRYSTAL GROWTH, 1988, 93 (1-4) : 201 - 206
  • [47] A Low-Cost and High-Precision Underwater Integrated Navigation System
    Liu, Jiapeng
    Yu, Te
    Wu, Chao
    Zhou, Chang
    Lu, Dihua
    Zeng, Qingshan
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2024, 12 (02)
  • [48] HIGH-PRECISION REAL-TIME BEAM POSITION MEASUREMENT SYSTEM
    KLEMAN, KJ
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 1465 - 1467
  • [49] Low-cost, high-precision measurement system for capacitive sensors
    Kolle, C
    O'Leary, P
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (03) : 510 - 517
  • [50] High-precision time synchronization of 5G-TSN system
    Li X.
    Wang X.
    Fan T.
    Zhang F.
    Liu J.
    Wan H.
    Xi Tong Gong Cheng Yu Dian Zi Ji Shu/Systems Engineering and Electronics, 2023, 45 (02): : 559 - 565