Influence and optimization of building opening configurations on the performance of enhanced roof ventilation units (ERU): a numerical and orthogonal study

被引:0
|
作者
Tian, Lei [1 ,2 ]
Liu, Zu-An [1 ]
Li, You [3 ]
Hou, Jiawen [1 ]
Xiao, Yuling [2 ]
Fei, Fan [2 ]
Xia, Yueqiu [2 ]
Yao, Wanxiang [2 ,4 ]
Fukuda, Hiroatsu [2 ]
机构
[1] Xuzhou Univ Technol, Sch Civil Engn, Xuzhou 221018, Peoples R China
[2] Univ Kitakyushu, Fac Environm Engn, Kitakyushu 8080135, Japan
[3] Ritsumeikan Univ, Asia Japan Res Inst, Ibaraki 5678570, Japan
[4] Qingdao Univ Technol, iSMART, Qingdao 266033, Peoples R China
关键词
Enhanced roof ventilation unit (ERU); Building opening configuration; Orthogonal design; Numerical simulation; Ventilation effect; THERMAL PERFORMANCE; ENERGY-CONSUMPTION; CROSS-VENTILATION; CFD SIMULATION; URBAN AREAS; EFFICIENCY; ENVIRONMENT; SUMMER; SYSTEM; AIR;
D O I
10.1016/j.csite.2025.105753
中图分类号
O414.1 [热力学];
学科分类号
摘要
Enhanced roof ventilation units (ERU) can significantly enhance indoor airflow and thermal comfort, but their effectiveness is influenced by building opening configurations. Therefore, the performance of ERU under different building opening factors (window height (A), window size (B), door size (C), window orientation (D), door orientation (G), and building orientation (O)) was explored through numerical simulations and orthogonal design. Meanwhile, these factors influence laws, degrees, significance levels, and optimal schemes were identified. The findings reveal that: (1) For volume flow rate, the influence ranking is O > C > B > D > G > A, while for outlet average air age and volume air age, the rankings are O > G > A > D > C > B and O > A > G > C > D > B; (2) The indoor combinatorial ventilation efficiency under optimal configuration is 9.75 %, the flow purification rate and air exchange efficiency are 20.21 % and 48.27 %; (3) The percentage dissatisfied (PDT and PDD) under optimal configuration are 0.31 %; (4) Local vortices can lead to poor ventilation performance, but indoor circulation can bring the air exchange efficiency approaching the ideal 50 %. (5) The opening configurations focus on building orientation and dominant wind direction. (6) Appropriate opening configurations are more conducive to ventilation than increasing the area openings. This research provides valuable insights for optimizing roof ventilation units and improving indoor thermal comfort.
引用
收藏
页数:19
相关论文
共 42 条
  • [21] Numerical study on ventilation duct layout in subway stations for smoke control performance optimization
    Chen, Junfeng
    Dong, Yang
    Zhong, Maohua
    Hua, Fucai
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2025, 258
  • [22] Computational Study on the Influence of Different Opening Position on Wind-induced Natural Ventilation in Urban Building of Cubical Array
    Kasim, N. F. M.
    Zaki, S. A.
    Ali, M. S. M.
    Ikegaya, N.
    Razak, A. A.
    FOURTH INTERNATIONAL CONFERENCE ON COUNTERMEASURES TO URBAN HEAT ISLAND, (UHI 2016), 2016, 169 : 256 - 263
  • [23] Numerical study on the thermal performance of building wall and roof incorporating phase change material panel for passive cooling application
    Kong, Xiangfei
    Lu, Shilei
    Li, Yiran
    Huang, Jingyu
    Liu, Shangbao
    Energy and Buildings, 2014, 81 : 404 - 415
  • [24] Numerical study on the thermal performance of building wall and roof incorporating phase change material panel for passive cooling application
    Kong, Xiangfei
    Lu, Shilei
    Li, Yiran
    Huang, Jingyu
    Liu, Shangbao
    ENERGY AND BUILDINGS, 2014, 81 : 404 - 415
  • [25] Numerical study on the thermal performance of building wall and roof incorporating phase change material panel for passive cooling application
    Kong, Xiangfei
    Lu, Shilei
    Li, Yiran
    Huang, Jingyu
    Liu, Shangbao
    Energy and Buildings, 2014, 81 : 404 - 415
  • [26] Optimization of Thermal Performance by Enhancing Natural Convection of Diverse Configurations of Fin Heat Sink Filled With Nano-Enhanced Phase Change Materials: A Numerical Study
    Omi, Mallik Nadim Arman
    HEAT TRANSFER, 2025, 54 (02) : 1267 - 1280
  • [27] Numerical Study on the Influence of Well Layout on Electricity Generation Performance of Enhanced Geothermal Systems
    Zeng, Yuchao
    Sun, Fangdi
    Zhai, Haizhen
    PROCESSES, 2021, 9 (08)
  • [28] Numerical study on supply parameters’ influence on ventilation performance of a personalized air conditioning system for sleeping environments
    Mao Ning
    Yu Hao
    Zhuang Jiaojiao
    Song Mengjie
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 11331 - 11343
  • [29] Numerical study on supply parameters' influence on ventilation performance of a personalized air conditioning system for sleeping environments
    Mao Ning
    Yu Hao
    Zhuang Jiaojiao
    Song Mengjie
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (20) : 11331 - 11343
  • [30] Application of actively enhanced solar phase change heat storage system in building heating: A numerical and statistical optimization study
    Huang, Xinyu
    Liu, Zemin
    Gao, Xinyu
    Xie, Yuan
    Gao, Jiayi
    Yang, Xiaohu
    RENEWABLE ENERGY, 2025, 241