Comparison Between Attenuation Measurement and the Controlled Attenuation Parameter for the Assessment of Hepatic Steatosis Based on MRI Images

被引:0
|
作者
Gotoh, Tatsuya [1 ]
Kumada, Takashi [2 ]
Ogawa, Sadanobu [1 ]
Niwa, Fumihiko [1 ]
Toyoda, Hidenori [3 ]
Hirooka, Masashi [4 ]
Koizumi, Yohei [4 ]
Hiasa, Yoichi [4 ]
Akita, Tomoyuki [5 ]
Tanaka, Junko [5 ]
Shimizu, Masahito [6 ]
机构
[1] Ogaki Municipal Hosp, Dept Imaging Diag, Ogaki, Japan
[2] Gifu Kyoritsu Univ, Fac Nursing, Dept Nursing, Ogaki, Japan
[3] Ogaki Municipal Hosp, Dept Gastroenterol & Hepatol, Ogaki, Japan
[4] Ehime Univ, Dept Gastroenterol & Metabiol, Grad Sch Med, Matsuyama, Ehime, Japan
[5] Hiroshima Univ, Inst Biomed & Hlth Sci, Dept Epidemiol Infect Dis Control & Prevent, Hiroshima, Japan
[6] Gifu Univ, Grad Sch Med, Dept Gastroenterol Internal Med, Gifu, Japan
关键词
attenuation coefficient; attenuation measurement; Bland-Altman analysis; controlled attenuation parameter; hepatic steatosis; MRI-derived proton density fat fraction; FATTY LIVER-DISEASE; ULTRASOUND; AGREEMENT; FIBROSIS; CRITERIA;
D O I
10.1111/liv.16210
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: This study prospectively compared the diagnostic accuracies of the improved Attenuation Measurement (iATT) algorithm and the Controlled Attenuation Parameter (CAP) and assessed the interchangeability of iATT with magnetic resonance imaging-derived proton density fat fraction (MRI-derived PDFF). Methods: Patients with chronic liver disease were prospectively enrolled and underwent iATT, CAP and MRI-derived PDFF measurements for hepatic steatosis evaluation. According to MRI-derived PDFF values, steatosis grades were categorised as steatosis (S)0 (< 5.2%), S1 (>= 5.2%, < 11.3%), S2 (>= 11.3%, < 17.1%) and S3 (>= 17.1%). Correlation coefficients (CCs) were determined, diagnostic performances were compared by the area under the receiver operating characteristic curve (AUROC) and agreement was evaluated using the calculated percentage error (PE) and expected limit of agreement (LOA). Results: A total of 414 patients (median age 64 years, 203 females) were evaluated. The CC between iATT and MRI-derived PDFF was 0.727 (95% confidence interval [CI] 0.678-0.770), which was higher than that between CAP and MRI-derived PDFF at 0.615 (95% CI 0.551-0.672) (p < 0.001). The AUROCs of iATT for >= S1, >= S2 and >= S3 were 0.901 (95% CI 0.870-0.931), 0.878 (95% CI 0.846-0.910) and 0.839 (95% CI 0.794-0.883), respectively. The diagnostic performances of iATT for >= S1 and >= S2 showed significantly higher AUROCs than those of CAP (p < 0.001, p = 0.036, respectively). The calculated PE and the expected LOA for CAP and iATT were 38.94% and 22.66% and 32.94% and 30.03%, respectively. Conclusions: iATT was superior to CAP and comparable to MRI-derived PDFF in assessing hepatic steatosis.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Controlled attenuation parameter for the detection of hepatic steatosis in patients with chronic hepatitis B
    Chen, Jing
    Wu, Dongbo
    Wang, Menglan
    Chen, Enqiang
    Bai, Lang
    Liu, Cong
    Liao, Juan
    Tang, Hong
    INFECTIOUS DISEASES, 2016, 48 (09) : 670 - 675
  • [32] Predicting Hepatic Steatosis in Living Liver Donors Via Controlled Attenuation Parameter
    Yen, Y. H.
    Kuo, F. Y.
    Lin, C. C.
    Chen, C. L.
    Chang, K. C.
    Tsai, M. C.
    Hu, T. H.
    TRANSPLANTATION PROCEEDINGS, 2018, 50 (10) : 3533 - 3538
  • [33] Controlled Attenuation Parameter for Noninvasive Assessment of Hepatic Steatosis Using Fibroscan®: Validation in Chronic Hepatitis B
    Mi, Yu-Qiang
    Shi, Qi-Yu
    Xu, Liang
    Shi, Rui-Fang
    Liu, Yong-Gang
    Li, Ping
    Shen, Feng
    Lu, Wei
    Fan, Jian-Gao
    DIGESTIVE DISEASES AND SCIENCES, 2015, 60 (01) : 243 - 251
  • [34] ACCURACY OF CONTROLLED ATTENUATION PARAMETER (CAP) TO PREDICT HEPATIC STEATOSIS IN OBESE PATIENTS
    Owen, Samuel
    King, Christopher
    Cho, Ryan
    Juakiem, Wassem
    Sarkar, Sonali
    Aden, James
    Morales-Cardona, Amilcar L.
    Paredes, Angelo H.
    HEPATOLOGY, 2019, 70 : 1084A - 1085A
  • [35] Clinical significance of hepatic steatosis according to coronary plaque morphology: assessment using controlled attenuation parameter
    Park, Hyo Eun
    Lee, Heesun
    Choi, Su-Yeon
    Kwak, Min-Sun
    Yang, Jong In
    Yim, Jeong Yoon
    Chung, Goh Eun
    JOURNAL OF GASTROENTEROLOGY, 2019, 54 (03) : 271 - 280
  • [36] Assessment of the hepatic steatosis using controlled attenuation parameter (CAP) measured with transient elastography in healthy population
    Hong, Y. M.
    Yoon, K. T.
    Cho, M.
    Heo, J.
    Woo, H. Y.
    Chu, C. W.
    Rhu, J. H.
    Yang, K. H.
    JOURNAL OF HEPATOLOGY, 2017, 66 (01) : S597 - S597
  • [37] Clinical significance of hepatic steatosis according to coronary plaque morphology: assessment using controlled attenuation parameter
    Hyo Eun Park
    Heesun Lee
    Su-Yeon Choi
    Min-Sun Kwak
    Jong In Yang
    Jeong Yoon Yim
    Goh Eun Chung
    Journal of Gastroenterology, 2019, 54 : 271 - 280
  • [38] Controlled attenuation parameter (CAP) of transient elastography is an accurate non-invasive assessment of hepatic steatosis
    Wong, Grace L. H.
    Wong, Vincent W. S.
    Lai, Jennifer W. Y.
    Chim, Angel M. L.
    Chan, Henry L. Y.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 239 - 240
  • [39] Controlled attenuation parameter for non-invasive assessment of hepatic steatosis: Does etiology affect performance?
    Kumar, Manoj
    Rastogi, Archana
    Singh, Tarandeep
    Behari, Chhagan
    Gupta, Ekta
    Garg, Hitendra
    Kumar, Ramesh
    Bhatia, Vikram
    Sarin, Shiv K.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 (07) : 1194 - 1201
  • [40] Controlled Attenuation Parameter for Noninvasive Assessment of Hepatic Steatosis Using Fibroscan®: Validation in Chronic Hepatitis B
    Yu-Qiang Mi
    Qi-Yu Shi
    Liang Xu
    Rui-Fang Shi
    Yong-Gang Liu
    Ping Li
    Feng Shen
    Wei Lu
    Jian-Gao Fan
    Digestive Diseases and Sciences, 2015, 60 : 243 - 251