Maximum Allowable TCF Calibration Error for Robotic Pose Servoing

被引:1
|
作者
Hou, Jun [1 ,2 ]
Xing, Shiyu [1 ,2 ]
Ma, Yunkai [1 ,2 ]
Jing, Fengshui [1 ,2 ]
Tan, Min [3 ]
机构
[1] Chinese Acad Sci, Inst Automat, State Key Lab Multimodal Artificial Intelligence S, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Sch Artificial Intelligence, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Inst Automat, Key Lab Cognit & Decis Intelligence Complex Syst, Beijing 100190, Peoples R China
来源
IEEE ROBOTICS AND AUTOMATION LETTERS | 2025年 / 10卷 / 02期
基金
中国国家自然科学基金;
关键词
Calibration; Robots; Robot kinematics; Stars; Assembly; Servomotors; Robustness; Measurement uncertainty; Accuracy; Visualization; Formal methods in robotics and automation; calibration and identification; assembly;
D O I
10.1109/LRA.2024.3522840
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Robotic pose servoing aims to move the robot end-effector to the target pose. Closed-loop servo systems can tolerate a small TCF (tool control frame) calibration error and accurately reach the target pose through multiple pose measurements and pose adjustments. However, the maximum allowable TCF calibration error remains an open question. This paper demonstrates that the necessary condition for robotic pose servoing is a TCF calibration error angle of less than 60 degrees, with no limit on the translational component of the TCF calibration error. Next, an improved pose servoing method is proposed to address the conflict between the large TCF error and the limited robot workspace. This method introduces a scaling factor to limit the adjustment range within the robot workspace, ensuring greater robustness. Finally, robot-assisted cabin docking is selected as an experimental validation case. Simulation and physical experiments validate the maximum allowable TCF calibration error. Comparative experiments confirm the robustness of the improved pose servoing method, achieving cabin docking despite significant TCF calibration errors.
引用
收藏
页码:1744 / 1751
页数:8
相关论文
共 50 条
  • [31] Calibration error of robotic vision system of 3D laser scanner
    Qi, Lizhe
    Tang, Qing
    Yun, Chao
    Wang, Jing
    Gan, Zhongxue
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2011, 47 (13): : 9 - 15
  • [32] An improved minimal error model for the robotic kinematic calibration based on the POE formula
    Luo, Ruiqing
    Gao, Wenbin
    Huang, Qi
    Zhang, Yi
    ROBOTICA, 2022, 40 (05) : 1607 - 1626
  • [33] Optimal kinematic calibration of robots based on the maximum positioning-error estimation
    Department of Mechanical Sciences and Engineering, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo, 152-8552, Japan
    Nihon Kikai Gakkai Ronbunshu C, 2008, 12 (3069-3076):
  • [34] Laser interferometry measurements based calibration and error propagation identification for pose estimation in mobile robots
    Jimenez, Paulo A.
    Shirinzadeh, Bijan
    ROBOTICA, 2014, 32 (01) : 165 - 174
  • [35] USE OF PATIENT AND CLINICIAN SURVEYS TO DETERMINE THE MAXIMUM ANALYTICAL ERROR ALLOWABLE IN PORTABLE WHOLE-BLOOD GLUCOSE METERS
    CEMBROWSKI, GS
    WEISS, S
    MAZZE, RS
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1006 - 1006
  • [36] Robotic Positional Error Calibration Based on a Hybrid Data-driven Prediction Framework
    Zhu, Jiahui
    Yan, Sijie
    Yang, Zeyuan
    Cai, Wenqi
    Ding, Han
    2023 29TH INTERNATIONAL CONFERENCE ON MECHATRONICS AND MACHINE VISION IN PRACTICE, M2VIP 2023, 2023,
  • [37] Calibration, handling repeatability, and the Maximum Permissible Error of single-volume glass instruments
    Veronika R. Meyer
    Josef Pfohl
    Burkhard Winter
    Accreditation and Quality Assurance, 2010, 15 : 705 - 708
  • [38] Calibration, handling repeatability, and the Maximum Permissible Error of single-volume glass instruments
    Meyer, Veronika R.
    Pfohl, Josef
    Winter, Burkhard
    ACCREDITATION AND QUALITY ASSURANCE, 2010, 15 (12) : 705 - 708
  • [39] Model-free visual servoing based on active disturbance rejection control and adaptive estimator for robotic manipulation without calibration
    Tian, Jun
    Zhong, Xungao
    Peng, Xiafu
    Hu, Huosheng
    Liu, Qiang
    INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2024, 51 (05): : 820 - 836
  • [40] An Integrated Two-Pose Calibration Method for Estimating Head-Eye Parameters of a Robotic Bionic Eye
    Chen, Xiaopeng
    Wang, Changjin
    Zhang, Weizhong
    Lan, Kunyan
    Huang, Qiang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (04) : 1664 - 1672