Energy response of CaSO4:Dy thermoluminescence detector to medical linear accelerator photon beams

被引:0
|
作者
Herwiningsih, Sri [1 ]
Izzati, Lia Wilda [1 ]
Bunawas, Bunawas [2 ]
机构
[1] Univ Brawijaya, Fac Math & Nat Sci, Phys Dept, 1 Vet St, Malang 65145, East Java, Indonesia
[2] Nuklindo Lab, Res & Dev Div, Dept Math, 5A Ir H Juanda St,Block B Kav P-Q, South Tangerang 15412, Indonesia
关键词
D O I
10.1093/rpd/ncae211
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study aims to evaluate the energy response of the thermoluminescent dosemeter (TLD) CaSO4:Dy from high energy photon beams produced from medical linear accelerator. The test was performed on the polymethyl methacrylate phantom surface and at the depth of dose maximum with a source-to-surface distance of 100 cm and the radiation field size of 12 x 12 cm. The results were compared with the TLD response exposed to Co-60 standard source. The results show that the TLD response to the linac's photon differs >30% compared to the TLD response to Co-60 exposure when measured at the phantom surface, while at the depth of maximum dose the response is similar (< +/- 10%), indicating that the TLD response is no longer dependent on the energy. This implies that the current dose reading evaluation based on Co-60 calibration curve should be corrected to obtain more accurate dose report of the radiation workers.
引用
收藏
页码:2014 / 2020
页数:7
相关论文
共 50 条
  • [1] High dose and phototransferred thermoluminescence in CaSO4, CaSO4:Dy, and CaSO4:Tm
    Lewandowski, AC
    Mathur, VK
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 213 - 216
  • [2] Thermoluminescence characteristic of CaSO4:Dy on β and γ radiation
    Nuraeni, N.
    Kartikasari, D.
    Yani, S.
    Hiswara, E.
    Haryanto, F.
    Iskandar, F.
    Waris, A.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [3] Thermoluminescence emission, excitation and stimulation spectra of CaSO4:Dy and CaSO4:Tm
    Lewandowski, AC
    Barkyoumb, JH
    Mathur, VK
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 281 - 286
  • [4] Mechano and thermoluminescence of γ-irradiated CaSO4:Dy phosphor
    Kher, RS
    Pandey, RK
    Dhoble, SJ
    Khokhar, MSK
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 281 - 284
  • [5] Mechano and thermoluminescence of γ-irradiated CaSO4:Dy phosphor
    Kher, RS
    Pandey, RK
    Dhoble, SJ
    Khokhar, MSK
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 281 - 284
  • [6] THERMOLUMINESCENCE CHARACTERISTICS OF CASO4 DOPED WITH DY AND CU
    SRIVASTAVA, JK
    BHATT, BC
    SUPE, SJ
    RADIATION PROTECTION DOSIMETRY, 1992, 40 (04) : 271 - 274
  • [7] Response of CaSO4:Dy based TL dosemeter system to high-energy photon beams:: Theoretical simulation
    Bakshi, A. K.
    Chatterjee, S.
    Kher, R. K.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (04) : 456 - 462
  • [8] Cathodoluminescence and green-thermoluminescence response of CaSO4:Dy,P films
    Roman-Lopez, J.
    Correcher, V.
    Garcia-Guinea, J.
    Rivera, T.
    Lozano, I. B.
    JOURNAL OF LUMINESCENCE, 2013, 135 : 89 - 92
  • [9] CASO4: DY response to radiation-therapy electron beams
    Nunes, M.
    Campos, L.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S133 - S134
  • [10] Response of CaSO4:Dy phosphor based TLD badge system to high energy electron beams from medical linear accelerator and estimation of whole body dose and skin dose
    Chatterjee, S.
    Bakshi, A. K.
    Kinhikar, R. A.
    Chourasiya, G.
    Kher, R. K.
    RADIATION MEASUREMENTS, 2009, 44 (03) : 257 - 262