Neuraxial Anesthesia and Risk of Root Damage: A 3D Ex Vivo Study

被引:0
|
作者
Labandeyra, Hipolito [1 ,2 ]
Sala-Blanch, Xavier [1 ,3 ]
Prats-Galino, Alberto [1 ]
Puigdellivol-Sanchez, Anna [1 ,4 ]
机构
[1] Univ Barcelona, Fac Med & Hlth Sci, Human Anat & Embryol Unit, Lab Surg Neuroanat LSNA, Barcelona 08036, Spain
[2] HM Delfos Hosp, Anesthesiol Serv, Div Reg Anesthesia, Barcelona 08023, Spain
[3] Hosp Clin Barcelona, Anesthesiol Serv, Div Reg Anesthesia, Barcelona 08036, Spain
[4] CAP Anton Borja Ctr Universitari, Med Familia, Consorci Sanit Terrassa, Rubi 08191, Spain
来源
NEUROSCI | 2024年 / 5卷 / 04期
关键词
regional anesthesia; needle insertion; angles; 3D reconstruction; ex vivo; INTERACTIVE MODEL; LUMBAR; PUNCTURE;
D O I
10.3390/neurosci5040044
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Cauda equina nerve roots may become damaged during neuraxial anesthesia, and post-puncture headache may appear in the case of cerebrospinal fluid leakage if needle tips are deformed due to bone contact when several attempts are needed. Our aim was to verify the correlation between skin-transverse process distance (st) and skin-dural sac distance (d) for calculation of optimal angles in a free visual guide and as a reference for the maximal depth to be traversed by the needle. Randomly selected ex vivo samples (n = 10) were flexed to reproduce the position of the lumbosacral spine during spinal anesthesia. Spinal needles were inserted perpendicular to the skin either blindly or following the inferred paramedian angle corresponding to ultrasound-measured (d). After computed tomography and three-dimensional reconstruction, both (st) and (d) were measured, and the Pearson correlation index was calculated. A free 3D-PDF tool was used to illustrate the potential affectation of nerve cuffs by needles located lateral to the dural sac. Correlation between (d) and (st) was 0.84-0.93 at L4L5-L3L4 intervertebral levels, and most needle tips were located within the spinal canal, but some traversed the zone where nerve cuffs emerge. In conclusion, ultrasound may determine if a perpendicular needle insertion is viable at midline. If not, the optimal paramedian angle and maximal depth may be determined by measuring (st).
引用
收藏
页码:623 / 634
页数:12
相关论文
共 50 条
  • [1] 3D kinematics of the glenohumeral joint during abduction motion: an ex vivo study
    F. Billuart
    L. Devun
    O. Gagey
    W. Skalli
    D. Mitton
    Surgical and Radiologic Anatomy, 2007, 29 : 291 - 295
  • [2] 3D kinematics of the glenohumeral joint during abduction motion: an ex vivo study
    Billuart, F.
    Devun, L.
    Gagey, O.
    Skalli, W.
    Mitton, D.
    SURGICAL AND RADIOLOGIC ANATOMY, 2007, 29 (04) : 291 - 295
  • [3] Sem and 3D reconstruction of ex-vivo arterial thrombi: A pilot study
    Barath, B.
    Glauser, F.
    Noble, S.
    Fontana, P.
    Marchi, R.
    Neerman-Arbez, M.
    Casini, A.
    SWISS MEDICAL WEEKLY, 2022, 152 : 57S - 58S
  • [4] Smear Layer and Debris Removal from Root Canals Comparing Traditional Syringe Irrigation and 3D Cleaning: An Ex Vivo Study
    Iandolo, Alfredo
    Pisano, Massimo
    Abdellatif, Dina
    Sangiovanni, Giuseppe
    Pantaleo, Giuseppe
    Martina, Stefano
    Amato, Alessandra
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (02)
  • [5] 3D magnetic resonance microscopy of the ex vivo retina
    De La Garza, Bryan H.
    Muir, Eric R.
    Shih, Yen-Yu I.
    Duong, Timothy Q.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (04) : 1154 - 1158
  • [6] Development of an 3D ex vivo model of bone tissue
    Gamblin, A. L.
    Renaud, A.
    Amimaud, J.
    Hulin, P.
    Trichet, V.
    Heymann, D.
    Layrolle, P.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 : 350 - 350
  • [7] 3D Flexible Endoscope; Feasibility During ESD in Ex-Vivo Animal Study
    Kikuchi, Daisuke
    Nomura, Kosuke
    Toba, Takahito
    Iizuka, Toshiro
    Tanaka, Masami
    Hoteya, Shu
    Kaise, Misturu
    GASTROINTESTINAL ENDOSCOPY, 2016, 83 (05) : AB484 - AB484
  • [8] 3D ultrasound imaging with active instrumented needle tip tracking: An ex vivo study
    Rostami, Javad
    Baker, Christian
    Liang, Weidong
    West, Simeon
    Vercauteren, Tom
    Mathews, Sunish
    Desjardins, Adrien
    Zhang, Edward
    Beard, Paul
    Ourselin, Sebastien
    Peralta, Laura
    Xia, Wenfeng
    2024 IEEE ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL JOINT SYMPOSIUM, UFFC-JS 2024, 2024,
  • [9] An Ex Vivo Pilot Study to Assess the Feasibility of 3D Printing of Orbital Implants in Horses
    Jarry, Jenny
    De Raeve, Yves
    Dugdale, Alexandra
    Simon, Vincent
    Vandeweerd, Jean-Michel
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2023, 128
  • [10] A preliminary ex vivo study of 3D ultrasonography of aortic atherosclerosis using autopsied aorta
    Koga, Masatoshi
    Sato, Kazuaki
    Ishibashi-Ueda, Hatsue
    Tanaka, Koji
    Suzuki, Rieko
    Sumita, Yoshiyuki
    Minematsu, Kazuo
    Toyoda, Kazunori
    INTERNATIONAL JOURNAL OF STROKE, 2016, 11 (07) : NP74 - NP75