Protocol for assessing and visualizing cell microaggregate formation in whole blood by imaging flow cytometry

被引:0
|
作者
Krell, Johannes [1 ]
Javarappa, Komal Kumar [2 ]
Wenedy, Angie [1 ,2 ]
Frelinger, Andrew L., III
Renia, Laurent [3 ,4 ]
Costa, Clarissa Prazeres da [5 ,6 ,7 ]
Schlegel, Martin [1 ]
Knolle, Percy [8 ]
Schneider, Gerhard [1 ]
Hayden, Oliver [9 ,10 ]
机构
[1] TUM Univ Hosp Munchen, Dept Anesthesiol & Intens Care Med, Munich, Germany
[2] TUM Create Ltd, CREATE Way 10-02,CREATE Tower, Singapore 138602, Singapore
[3] ASTAR, ASTAR Infect Dis Labs, Singapore, Singapore
[4] Nanyang Technol Univ, Sch CE, Singapore, Singapore
[5] German Ctr Infect Res DZIF, Partner Site Munich, Munich, Germany
[6] TUM, Ctr Global Hlth, Sch Med & Hlth, Munich, Germany
[7] TUM, Inst Med Mikrobiol Immunol & Hyg, Sch Med & Hlth, Trogerstr 30, D-81675 Munich, Germany
[8] Tech Univ Munich, Klinikum Rechts Isar, Inst Mol Immunol & Expt Oncol, D-81675 Munich, Germany
[9] TUM, Heinz Nixdorf Chair Biomed Elect, TranslaTUM, Sch Computat Informat & Technol, Einsteinstr 25, D-81675 Munich, Germany
[10] TUM, Munich Inst Biomed Engn, D-85748 Munich, Germany
来源
STAR PROTOCOLS | 2025年 / 6卷 / 01期
关键词
D O I
10.1016/j.xpro.2025.103598
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Blood cell aggregates are clinically useful biomarkers in a number of medical disorders. This protocol provides accurate and quantitative analysis of cell aggregates using a small volume of whole blood and imaging flow cytometry. We describe steps for sample collection, staining, and measurement. We then detail gating procedures and analysis of cell morphology. Sample preparation artifacts, activation, and morphological changes of cells are mitigated by omitting erythrocyte lysis and leukocyte isolation while maintaining high-throughput accurate imaging of leukocytes and platelets.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Application of six-color flow cytometry for the assessment of dendritic cell responses in whole blood assays
    Della Bella, Silvia
    Giannelli, Stefania
    Taddeo, Adriano
    Presicce, Pietro
    Villa, Maria Luisa
    JOURNAL OF IMMUNOLOGICAL METHODS, 2008, 339 (02) : 153 - 164
  • [42] Counting absolute number of lymphocytes in quail whole blood by flow cytometry
    Uchiyama, R
    Moritomo, T
    Kai, O
    Uwatoko, K
    Inoue, Y
    Nakanishi, T
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2005, 67 (04): : 441 - 444
  • [43] Platelet calcium flux measurement by flow cytometry in diluted whole blood
    Wilbourn, B.
    Riddell, A.
    Foxton, E.
    Gomez, K.
    Chowdary, P.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2016, 14 : 114 - 115
  • [44] Fiber-optic multiphoton flow cytometry in whole blood and in vivo
    Chang, Yu-Chung
    Ye, Jing Yong
    Thomas, Thommey P.
    Cao, Zhengyi
    Kotlyar, Alina
    Tkaczyk, Eric R.
    Baker, James R., Jr.
    Norris, Theodore B.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (04)
  • [45] Investigation of platelet-neutrophil interactions in whole blood by flow cytometry
    Peters, MJ
    Heyderman, RS
    Hatch, DJ
    Klein, NJ
    JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 209 (02) : 125 - 135
  • [46] Reticulocytes and reticulated platelets: Simultaneous measurement in whole blood by flow cytometry
    Rapi, S
    Ermini, A
    Bartolini, L
    Caldini, A
    Del Genovese, A
    Miele, AR
    Buggiani, A
    Fanelli, A
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (04) : 211 - 214
  • [47] Magnetic fingerprints of rolling cells for quantitative flow cytometry in whole blood
    Mathias Reisbeck
    Michael Johannes Helou
    Lukas Richter
    Barbara Kappes
    Oliver Friedrich
    Oliver Hayden
    Scientific Reports, 6
  • [48] Flow cytometry counting of CD34+ cells in whole blood
    Fornas, O
    Garcia, J
    Petriz, J
    NATURE MEDICINE, 2000, 6 (07) : 833 - +
  • [49] The effects of aprotinin on platelets in vitro using whole blood flow cytometry
    Kozek-Langenecker, SA
    Mohammad, SF
    Masaki, T
    Green, W
    Kamerath, C
    Cheung, AK
    ANESTHESIA AND ANALGESIA, 2000, 90 (01): : 12 - 16
  • [50] NEUTROPHIL AGGREGATION MEASURED IN WHOLE-BLOOD BY FLOW-CYTOMETRY
    SIMON, SI
    SKLAR, LA
    FASEB JOURNAL, 1991, 5 (05): : A1143 - A1143