Accuracy of the Glucose Test in the i-STAT® G Cartridge Using the i-STAT 1 System for Venous, Arterial and Capillary Whole Blood Specimens in Clinical Settings

被引:0
|
作者
Kornfeld, S. F. [1 ]
Aguirre, M. Gonzalez [1 ]
Zhang, H. [1 ]
Hahn, S. [1 ]
机构
[1] Abbott Point Care, Ottawa, ON, Canada
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A-328
引用
收藏
页数:2
相关论文
共 47 条
  • [11] Evaluation of the i-STAT® Portable Clinical Analyzer for the determination of blood creatinine.
    Marver, CL
    Santrach, PJ
    Burritt, MF
    CLINICAL CHEMISTRY, 1999, 45 (06) : A33 - A33
  • [12] The accuracy of the i-STAT portable analyser for measuring blood gases and pH in whole-blood samples from dogs
    Verwaerde, P
    Malet, C
    Lagente, M
    De la Farge, F
    Braun, JP
    RESEARCH IN VETERINARY SCIENCE, 2002, 73 (01) : 71 - 75
  • [13] EVALUATION OF A NOVEL POINT-OF-CARE SYSTEM, THE I-STAT PORTABLE CLINICAL ANALYZER
    ERICKSON, KA
    WILDING, P
    CLINICAL CHEMISTRY, 1993, 39 (02) : 283 - 287
  • [14] EVALUATION OF BLOOD-GAS AND PH METHODS ON THE I-STAT(TM) PORTABLE CLINICAL ANALYZER
    BOTTJEN, PL
    HAVEN, MC
    CLINICAL CHEMISTRY, 1995, 41 (06) : S196 - S196
  • [15] Selected Blood Chemistry and Gas Reference Ranges for Broiler Breeders Using the i-STAT® Handheld Clinical Analyzer
    Martin, Michael P.
    Wineland, Michael
    Barnes, H. John
    AVIAN DISEASES, 2010, 54 (03) : 1016 - 1020
  • [16] The i-STAT analyser, a new, hand-held whole blood analyser for measurement of haematocrit, electrolytes, and blood gases
    Schneider, J
    Dudziak, K
    Westphal, K
    Vettermann, J
    ANAESTHESIST, 1997, 46 (08): : 704 - 714
  • [17] Assessment of using fingerstick blood sample with i-STAT point-of-care device for cardiac troponin I assay
    Loewenstein, Devin
    Stake, Christine
    Cichon, Mark
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (08): : 1236 - 1239
  • [18] A novel developmental physiology laboratory exercise using the i-STAT point-of-care clinical analyzer
    Murphy, MJ
    FASEB JOURNAL, 2003, 17 (04): : A8 - A8
  • [19] Analytical evaluation of i-STAT portable clinical analyzer for blood gas and electrolyte analyses in pediatric samples.
    Murthy, JN
    Hicks, JM
    Soldin, SJ
    CLINICAL CHEMISTRY, 1996, 42 (06) : 198 - 198
  • [20] Analysis of bloodgas, electrolytes and glucose from intraosseous samples using an i-STAT® point-of-care analyser
    Veldhoen, Esther S.
    de Vooght, Karen M. K.
    Slieker, Martijn G.
    Versluys, Anne B.
    Turner, Nigel Mcb.
    RESUSCITATION, 2014, 85 (03) : 359 - 363