Comparison of Echo Planar and Turbo Spin Echo Diffusion-Weighted Imaging in Intraoperative MRI

被引:1
|
作者
Thorpe, James C. [1 ]
Thust, Stefanie C. [2 ,3 ,4 ,5 ]
Gillon, Claire H. M. [6 ]
Rowe, Selene [6 ]
Swain, Charlotte E. [6 ]
MacArthur, Donald C. [7 ,8 ]
Howarth, Simon P. [7 ]
Avula, Shivaram [9 ]
Morgan, Paul S. [1 ,2 ,3 ,5 ]
Dineen, Rob A. [1 ,2 ,3 ,8 ]
机构
[1] Nottingham Univ Hosp, Med Phys & Clin Engn, Nottingham, England
[2] Univ Nottingham, Sch Med, Acad Unit Mental Hlth & Clin Neurosci, Radiol Sci, Nottingham, England
[3] NIHR Nottingham Biomed Res Ctr, Nottingham, England
[4] UCL Inst Neurol, Dept Brain Repair & Rehabil, Queen Sq, London, England
[5] Univ Nottingham, Sir Peter Mansfield Imaging Ctr, Nottingham, England
[6] Nottingham Univ Hosp, Radiol, Nottingham, England
[7] Nottingham Univ Hosp, Neurosurg, Nottingham, England
[8] Univ Nottingham, Childrens Brain Tumour Res Ctr, Nottingham, England
[9] Alder Hey Childrens Hosp NHS Fdn Trust, Radiol, Liverpool, England
关键词
intraoperative MRI; diffusion; TSE diffusion; EPI diffusion; neurosurgery; RESECTION;
D O I
10.1002/jmri.29614
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Diffusion-weighted imaging (DWI) is routinely used in brain tumor surgery guided by intraoperative MRI (IoMRI). However, conventional echo planar imaging DWI (EPI-DWI) is susceptible to distortion and artifacts that affect image quality. Turbo spin echo DWI (TSE-DWI) is an alternative technique with minimal spatial distortions that has the potential to be the radiologically preferred sequence. Purpose: To compare via single- and multisequence assessment EPI-DWI and TSE-DWI in the IoMRI setting to determine whether there is a radiological preference for either sequence. Study type: Retrospective. Population: Thirty-four patients (22 female) aged 2-61 years (24 under 18 years) undergoing IoMRI during surgical resection of intracranial tumors. Field strength/sequence: 3-T, EPI-DWI, and TSE-DWI. Assessment: Patients were scanned with EPI- and TSE-DWI as part of the standard IoMRI scanning protocol. A single-sequence assessment of spatial distortion and image artifact was performed by three neuroradiologists blinded to the sequence type. Images were scored regarding distortion and artifacts, around and remote to the resection cavity. A multisequence radiological assessment was performed by three neuroradiologists in full radiological context including all other IoMRI sequences from each case. The DWI images were directly compared with scorings of the radiologists on which they preferred with respect to anatomy, abnormality, artifact, and overall preference. Statistical tests: Wilcoxon signed-rank tests for single-sequence assessment, weighted kappa for single and multisequence assessment. A P-value <0.001 was considered statistically significant. Results: For the blinded single-sequence assessment, the TSE-DWI sequence was scored equal to or superior to the EPI-DWI sequence for distortion and artifacts, around and remote to the resection cavity for every case. In the multisequence assessment, all radiologists independently expressed a preference for TSE-DWI over EPI-DWI sequences on viewing brain anatomy, abnormalities, and artifacts. Data conclusion: The TSE-DWI sequences may be favored over EPI-DWI for IoMRI in patients with intracranial tumors.
引用
收藏
页码:1847 / 1857
页数:11
相关论文
共 50 条
  • [21] Diffusion-weighted echo-planar MRI of lacunar infarcts
    K. Noguchi
    T. Nagayoshi
    N. Watanabe
    T. Kanazawa
    S. Toyoshima
    M. Morijiri
    H. Shojaku
    M. Shimizu
    H. Seto
    Neuroradiology, 1998, 40 : 448 - 451
  • [22] Diffusion-weighted imaging of the spinal cord: Interleaved echo-planar imaging is superior to fast spin-echo
    Bammer, R
    Augustin, M
    Prokesch, RW
    Stollberger, R
    Fazekas, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 364 - 373
  • [23] Diffusion-weighted echo-planar MRI of lacunar infarcts
    Noguchi, K
    Nagayoshi, T
    Watanabe, N
    Kanazawa, T
    Toyoshima, S
    Morijiri, M
    Shojaku, H
    Shimizu, M
    Seto, H
    NEURORADIOLOGY, 1998, 40 (07) : 448 - 451
  • [24] Turbo spin-echo diffusion-weighted MR of ischemic stroke
    Lovblad, KO
    Jakob, PM
    Chen, Q
    Baird, AE
    Schlaug, G
    Warach, S
    Edelman, RR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (02) : 201 - 208
  • [25] Comparison of turbo spin echo read-out with echo-planar imaging read-out for diffusion weighted imaging of the temporal lobes
    Eastwood, JD
    Liang, L
    Provenzale, JM
    RADIOLOGY, 2002, 225 : 467 - 467
  • [26] Diffusion-weighted imaging (DWI) in MR mammography (MRM): clinical comparison of echo planar imaging (EPI) and half-Fourier single-shot turbo spin echo (HASTE) diffusion techniques
    Baltzer, P. A. T.
    Renz, D. M.
    Herrmann, K. -H.
    Dietzel, M.
    Krumbein, I.
    Gajda, M.
    Camara, O.
    Reichenbach, J. R.
    Kaiser, W. A.
    EUROPEAN RADIOLOGY, 2009, 19 (07) : 1612 - 1620
  • [27] Diffusion-weighted imaging (DWI) in MR mammography (MRM): clinical comparison of echo planar imaging (EPI) and half-Fourier single-shot turbo spin echo (HASTE) diffusion techniques
    P. A. T. Baltzer
    D. M. Renz
    K.-H. Herrmann
    M. Dietzel
    I. Krumbein
    M. Gajda
    O. Camara
    J. R. Reichenbach
    W. A. Kaiser
    European Radiology, 2009, 19 : 1612 - 1620
  • [28] Comparison of Turbo Spin Echo and Echo Planar Imaging for intravoxel incoherent motion and diffusion tensor imaging of the kidney at 3 Tesla
    Hilbert, Fabian
    Wech, Tobias
    Neubauer, Henning
    Veldhoen, Simon
    Bley, Thorsten Alexander
    Koestler, Herbert
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (03): : 193 - 201
  • [29] Focal liver lesion detection and characterization: Comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging
    Coenegrachts, Kenneth
    Matos, Celso
    ter Beek, Leon
    Metens, Thierry
    Haspeslagh, Marc
    Bipat, Shandra
    Stoker, Jaap
    Rigauts, Hans
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) : 432 - 439
  • [30] Ultrafast MR imaging of the abdomen: Echo planar imaging and diffusion-weighted imaging
    Yamashita, Y
    Tang, Y
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 367 - 374