Clinical outcomes of using 3D-printed applicators for high-dose-rate brachytherapy in gynecological malignancy

被引:0
|
作者
Sittiwong, Wiwatchai [1 ]
Dankulchai, Pittaya [1 ]
Puangragsa, Utumporn [1 ]
Prasartseree, Tissana [1 ]
Tuntapakul, Pongpop [1 ]
Sathitwatthanawirot, Chanida [1 ]
Kittikornchaichan, Janiya [1 ]
Kongkum, Sansanee [1 ]
Piputpanukul, Niyada
Rojanapan, Kantarat
机构
[1] Mahidol Univ, Fac Med, Dept Radiol, Div Radiat Oncol,Siriraj Hosp, Bangkok, Thailand
关键词
HDR brachytherapy; gynecological cancer; vaginal recurrence; 3D-IGABT; 3D-printed applicator; survival outcome; ADVANCED VULVAR CANCER; RADIATION-THERAPY; GUIDED BRACHYTHERAPY; CERVICAL-CANCER; PHASE-II; TRIAL; SURGERY;
D O I
10.5114/jcb.2024.146670
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the clinical outcomes and toxicities of using 3D-printed applicators for image-guided adap-tive brachytherapy (IGABT) in gynecological cancer patients. Material and methods: Fourteen patients with gynecological cancers, both primary and recurrent, treated with in-house 3D-printed applicators between 2021 and 2022 were included in the study, and their data were retrospectively reviewed. Timing and patterns of response to treatment were recorded. Kaplan-Meier estimates at 2 years post-treat-ment were analyzed to obtain local relapse-free survival (LRFS), distant metastasis-free survival (DMFS), progres-sion-free survival (PFS), and overall survival (OS) rates. Actuarial rates of genitourinary (GU), gastrointestinal (GI), and skin and mucosal toxicities were also reported. Results: The median follow-up time for all patients was 27 (IQR: 15.4-32.5) months. Among the primary cases, 2 patients had cervical cancer and 3 had extra-mammary Paget's disease of the vulva. For the recurrent cases, all patients had vaginal relapses. The most common primary cancers were cervical cancer (44.4%) and ovarian cancer (33.3%). At 3 months post-treatment, 13 patients (92.9%) achieved a complete response (CR), and 1 patient (7.1%) showed a partial response (PR). The 2-year rates of LRFS, DMFS, PFS, and OS for primary/recurrent cases were 100%/74.07%, 100%/88.9%, 100%/64.8%, and 100%/88.9%, respectively. The actuarial rates of >= grade 2 acute GU and GI toxicities were 7.1% for both groups. For late GU and GI toxicities, the actuarial rates were 14.3% and 21.4%, respectively. In terms of skin and mucosal toxicities, 4 patients (28.6%) developed acute grade 3 toxicity, and 1 patient (7.1%) experienced persistent grade 3 vaginal toxicity. Conclusions: IGABT treatment using 3D-printed applicators for HDR brachytherapy in challenging cases due to incompatibility of the standard applicators with the patient's anatomy or highly advance disease, has demonstrated encouraging outcomes and acceptable toxicity profile
引用
收藏
页码:428 / 436
页数:9
相关论文
共 50 条
  • [1] clinical outcomes of using 3D-printed applicators for HDR brachytherapy in gynecological malignancy
    Sittiwong, W.
    Dankulchai, P.
    Puangragsa, U.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1935 - S1936
  • [2] Introduction of novel 3D-printed superficial applicators for high-dose-rate skin brachytherapy
    Jones, Emma-Louise
    Baldion, Anna Tonino
    Thomas, Christopher
    Burrows, Tom
    Byrne, Nick
    Newton, Victoria
    Aldridge, Sarah
    BRACHYTHERAPY, 2017, 16 (02) : 409 - 414
  • [3] 3D-printed surface mould applicator for high-dose-rate brachytherapy
    Schumacher, Mark
    Lasso, Andras
    Cumming, Ian
    Rankin, Adam
    Falkson, Conrad B.
    Schreiner, L. John
    Joshi, Chandra
    Fichtinger, Gabor
    MEDICAL IMAGING 2015: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2015, 9415
  • [4] Custom 3D-printed applicators for high dose-rate brachytherapy in skin cancer
    Membrive Conejo, Ismael
    Pera Cegarra, Oscar
    Foro Arnalot, Palmira
    Reig Castillejo, Ana
    Rodriguez de Dios, Nuria
    Sanz Latiesas, Xavier
    Pujol Vallverdu, Ramon M.
    Quera Jordana, Jaume
    Fernandez-Velilla Cepria, Enric
    Algara Munoz, Victor
    Algara Lopez, Manuel
    BRACHYTHERAPY, 2021, 20 (06) : 1257 - 1264
  • [5] 3D-printed applicators for high dose rate brachytherapy: Dosimetric assessment at different infill percentage
    Ricotti, Rosalinda
    Vavassori, Andrea
    Bazani, Alessia
    Ciardo, Delia
    Pansini, Floriana
    Spoto, Ruggero
    Sammarco, Vittorio
    Cattani, Federica
    Baroni, Guido
    Orecchia, Roberto
    Jereczek-Fossa, Barbara Alicja
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1698 - 1706
  • [6] Organ sparing treatment for penile cancer using a 3D-printed high-dose-rate brachytherapy applicator
    Lee, Hugh H. C.
    Chiu, Tsuicheng D.
    Hrycushko, Brian
    Xiong, Zhenyu
    Hudak, Steve
    Woldu, Solomon
    Mauck, Ryan
    Corwin, Terry
    Meng, Xiaosong
    Margulis, Vitaly
    Desai, Neil
    Folkert, Michael R.
    Garant, Aurelie
    BRACHYTHERAPY, 2023, 22 (05) : 580 - 585
  • [7] 3D Printed Surface Applicators for High Dose Rate Brachytherapy
    Clarke, Scott
    Yewondwossen, Mammo
    Robar, James
    MEDICAL PHYSICS, 2016, 43 (08) : 4934 - 4935
  • [8] Characterization and Validation of 3D Printed High Dose Rate Brachytherapy Applicators
    Wiles, A.
    Pokhrel, S.
    Knewtson, T.
    Jia, Y.
    Goldbaum, D.
    Ballo, M.
    Izaguirre, E. W.
    MEDICAL PHYSICS, 2018, 45 (06) : E354 - E355
  • [9] Individualized 3D-printed templates for high-dose-rate interstitial multicathether brachytherapy in patients with breast cancer
    Aristei, Cynthia
    Lancellotta, Valentina
    Piergentini, Marco
    Costantini, Giacomo
    Saldi, Simonetta
    Chierchini, Sara
    Cavalli, Antonella
    Di Renzo, Luca
    Fiorucci, Oscar
    Guasticchi, Massimo
    Bini, Vittorio
    Ricci, Alessandro
    BRACHYTHERAPY, 2019, 18 (01) : 57 - 62
  • [10] The importance of immobilization of gynecological applicators in high dose rate brachytherapy
    Pella, S.
    Mikko, H.
    Nicolae, D.
    Casey, C.
    Shereen, C.
    Janeil, P.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S936 - S936