Calibration Error Reduction in Millimeter-Wave Load-Pull Systems Measuring Highly Reflective Loads

被引:0
|
作者
Baddeley, Alexander [1 ]
Quaglia, Roberto [1 ]
Tasker, Paul J. [1 ]
机构
[1] Cardiff Univ, Ctr High Frequency Engn, Cardiff CF24 3AA, Wales
基金
英国工程与自然科学研究理事会;
关键词
Calibration; Measurement uncertainty; Power measurement; Uncertainty; Gain measurement; Impedance measurement; Vectors; Receivers; Millimeter wave measurements; Frequency measurement; gallium arsenide; gallium nitride; high-electron-mobility transistors; load-pull (LP); microwave measurements; millimeter-wave; power amplifier (PA);
D O I
10.1109/TMTT.2024.3495544
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article investigates sources of calibration error inherent in the load-pull (LP) measurement of millimeter-wave transistors when high reflection coefficient loads are applied. In these conditions, the calibration error on relative metrics such as power gain and power added efficiency (PAE) can be significant and strongly dependent on the reflection coefficient. Using both simulations and experiments, the article tries to discriminate the source of uncertainty between noise and "operator" errors. While the former can be minimized by maximizing the dynamic range and improving the filtering on the receiver, the latter, linked to the small mechanical perturbations that occur when changing the system configuration from calibration to measurement, is unavoidable in most LP systems. To address this issue, the article proposes a method, based on the TRL calibration, that consists of load-pulling the thru and line calibration standards using the measurement system in its measurement configuration and calculating their scattering parameters using least-squares on the measured dataset. This enables a recalculation of the calibration coefficients previously obtained when the measurement system was configured for calibration and allows for a significant reduction in calibration error. This method has been tested and applied to measurements of mm-wave devices in both active and passive LP systems, demonstrating a significant impact on the measured performance metrics. Calibration error, at 82.5 GHz, is shown to have resulted in a power gain inaccuracy as high as 0.7 dB at a reflection coefficient of 0.7, which led to an underestimation of PAE of 8.9% for a gallium arsenide pHEMT.
引用
收藏
页数:13
相关论文
共 34 条
  • [1] Evaluation and Reduction of Calibration Residual Uncertainty in Load-Pull Measurements at Millimeter-Wave Frequencies
    Teppati, Valeria
    Bolognesi, C. R.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (03) : 817 - 822
  • [2] Highly Reflective Load-Pull
    Hashmi, Mohammad S.
    Ghannouchi, Fadhel M.
    Tasker, Paul J.
    Rawat, Karun
    IEEE MICROWAVE MAGAZINE, 2011, 12 (04) : 96 - 107
  • [3] Microwave & millimeter-wave amplifier design via load-pull techniques
    Itoh, Y
    GAAS IC SYMPOSIUM - 22ND ANNUAL, TECHNICAL DIGEST 2000, 2000, : 43 - 46
  • [4] Transistor Vector Load-Pull Characterization for Millimeter-Wave Power Amplifier Design
    Vadala, Valeria
    Raffo, Antonio
    Bosi, Gianni
    Crupi, Giovanni
    Vannini, Giorgio
    2012 79TH ARFTG MICROWAVE MEASUREMENT CONFERENCE (ARFTG), 2012,
  • [5] Enhanced Vector Calibration of Load-pull Measurement Systems
    Aldoumani, A.
    Williams, Tudor
    Lees, J.
    Tasker, P. J.
    2014 83RD ARFTG MICROWAVE MEASUREMENT CONFERENCE (ARFTG): MICROWAVE MEASUREMENTS FOR EMERGING TECHNOLOGIES, 2014,
  • [6] AN AUTOMATED MILLIMETER-WAVE ACTIVE LOAD-PULL MEASUREMENT SYSTEM BASED ON 6-PORT TECHNIQUES
    GHANNOUCHI, FM
    BOSISIO, RG
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (06) : 957 - 962
  • [7] HIGH-POWER MILLIMETER-WAVE MMIC AMPLIFIER DESIGN USING IMPROVED LOAD-PULL METHOD
    NAGATOMO, K
    KOIKE, S
    OKUBO, N
    SHIGAKI, M
    IEICE TRANSACTIONS ON ELECTRONICS, 1992, E75C (06) : 663 - 668
  • [8] A Millimeter Wave Six-port Reflectometer for Active Load-Pull Characterization
    Mohellebi, Reda
    Bergeault, Eric
    Abib, Ghalid Idir
    Huyart, Bernard
    40TH EUROPEAN MICROWAVE CONFERENCE, 2010, : 1575 - 1578
  • [9] A Yield-Improvement Method for Millimeter-Wave GaN MMIC Power Amplifier Design Based on Load-Pull Analysis
    Mao, Shuman
    Zhang, Wei
    Yao, Yuan
    Yu, Xuming
    Tao, Hongqi
    Guo, Fangjin
    Ren, Chunjiang
    Chen, Tangsheng
    Zhang, Bin
    Xu, Ruimin
    Yan, Bo
    Xu, Yuehang
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2021, 69 (08) : 3883 - 3895
  • [10] Millimeter Wave and Sub-THz Power Sweep and Active Load-Pull Measurements
    Dudkiewicz, Steve
    Galatro, Luca
    Rowland, Cliff
    MICROWAVE JOURNAL, 2024, 67 (03) : 60 - 70