Thermomechanical optimization of actively cooled thermal shield in PIP II Cryogenic Distribution System

被引:0
|
作者
Banaszkiewicz, T. [1 ]
Chorowski, M. [1 ]
Dhuley, R. C. [2 ]
Duda, P. [1 ]
Martinez, A. [2 ]
Polinski, J. [1 ]
Soyars, J. W. M. [2 ]
Stanclik, M. [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Wroclaw, Poland
[2] Fermilab Natl Accelerator Lab, POB 500, Batavia, IL 60510 USA
关键词
D O I
10.1088/1757-899X/1301/1/012160
中图分类号
O414.1 [热力学];
学科分类号
摘要
The PIP-II Cryogenic Distribution System (CDS) connects the cryogenic plant to the superconducting linac consisting of 23 modules. The helium stream flow through the PIP-II CDS is regulated by means of control valves located in the Distribution Valve Box. The cryomodules are supplied with helium from individual Bayonet Cans. The entire CDS process lines are shielded from the thermal radiation from the ambient vacuum jacket by actively cooled thermal shields. High efficiency of the thermal shield has been achieved by state-of-the-art optimization of its thermalization system consisting of thermal bridges connecting the shield to the high temperature helium return pipe nominally at 80 K. The temperature and stress analyses of the thermal shield have been performed numerically. The results obtained for the thermal shield of the PIP-II CDS Distribution Valve Box are compared with the solutions applied in other large science machines.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Optimization design of liquid-cooled battery thermal management system based on wavy tube
    Wang, Chenyu
    Liu, Fei
    Guo, Jiale
    IONICS, 2024, 30 (10) : 6135 - 6149
  • [32] Configuration optimization of battery pack in parallel air-cooled battery thermal management system using an optimization strategy
    Chen, Kai
    Wang, Shuangfeng
    Song, Mengxuan
    Chen, Lin
    APPLIED THERMAL ENGINEERING, 2017, 123 : 177 - 186
  • [33] Optimization of controllers in the thermal system using initial pheromone distribution in ant colony optimization
    Zhang, Qian
    Dong, Ze
    Han, Pu
    Wu, Zhongli
    Gao, Fang
    PROCEEDINGS OF THE 2008 IEEE INTERNATIONAL CONFERENCE ON INFORMATION REUSE AND INTEGRATION, 2008, : 22 - 27
  • [34] THERMAL EFFICIENCY OPTIMIZATION OF A MODULAR HIGH TEMPERATURE GAS-COOLED REACTOR PLANT BY EXTRACTION STEAM DISTRIBUTION
    Jiang, Di
    Dong, Zhe
    PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE2020), VOL 1, 2020,
  • [35] A flexible optimization study on air-cooled battery thermal management system by considering of system volume and cooling performance
    Lu, Hao
    Tang, Xiaole
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [36] Study on the Optimization of Cold Air Distribution System with Ice Thermal Storage
    Wang, Zhiwei
    Cai, Huihua
    Zhao, Lei
    He, Xiaoying
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 298 - 303
  • [37] Multiobjective optimization of air-cooled battery thermal management system based on heat dissipation model
    Jiahui Chen
    Xiaobo Zhao
    Biao Wang
    Chenghao Zhang
    Dongji Xuan
    Ionics, 2021, 27 : 1307 - 1322
  • [38] Configuration, design, and optimization of air-cooled battery thermal management system for electric vehicles: A review
    Akinlabi, A. Hakeem
    Solyali, Davut
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 125
  • [39] Optimization design of the forced air-cooled battery thermal management system with a stepped divergence plenum
    Suo, Yaohong
    Tang, Chengbo
    Yang, Huai
    JOURNAL OF ENERGY STORAGE, 2023, 73
  • [40] Multiobjective optimization of air-cooled battery thermal management system based on heat dissipation model
    Chen, Jiahui
    Zhao, Xiaobo
    Wang, Biao
    Zhang, Chenghao
    Xuan, Dongji
    IONICS, 2021, 27 (03) : 1307 - 1322