Optimizing range of motion in reverse shoulder arthroplasty

被引:0
|
作者
Mouchantaf, M. [1 ]
Parisi, M. [1 ]
Secci, G. [1 ]
Biegun, M. [1 ]
Chelli, M. [1 ]
Schippers, P. [1 ]
Boileau, P. [1 ]
机构
[1] Inst Chirurg Reparatrice ICR Locomoteur & Sports, Nice, France
来源
BONE & JOINT OPEN | 2024年 / 5卷 / 10期
关键词
GLENOID LATERALIZATION; INCLINATION; ANGLE; BONE; TILT;
D O I
10.1302/2633-1462.510.BJO-2024-0097.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims Optimal glenoid positioning in reverse shoulder arthroplasty (RSA) is crucial to provide impingement-free range of motion (ROM). Lateralization and inclination correction are not yet systematically used. Using planning software, we simulated the most used glenoid implant positions. The primary goal was to determine the configuration that delivers the best theoretical impingement-free ROM. Methods With the use of a 3D planning software (Blueprint) for RSA, 41 shoulders in 41 consecutive patients (17 males and 24 females; means age 73 years (SD 7)) undergoing RSA were planned. For the same anteroposterior positioning and retroversion of the glenoid implant, four different glenoid baseplate configurations were used on each shoulder to compare ROM: 1) no correction of the RSA angle and no lateralization (C-L-); 2) correction of the RSA angle with medialization by inferior reaming (C+M+); 3) correction of the RSA angle without lateralization by superior compensation (C+L-); and 4) correction of the RSA angle and additional lateralization (C+L+). The same humeral inlay implant and positioning were used on the humeral side for the four different glenoid configurations with a 3 mm symmetric 135 degrees inclined polyethylene liner. Results The configuration with lateralization and correction of the RSA angle (C+L+) led to better ROM in flexion, extension, adduction, and external rotation (p <= 0.001). Only internal rotation was not significantly different between groups (p = 0.388). The configuration where correction of the inclination was done by medialization (C+M+) led to the worst ROM in adduction, extension, abduction, flexion, and external rotation of the shoulder. Conclusion Our software study shows that, when using a 135 degrees inlay reversed humeral implant, correcting glenoid inclination (RSA angle 0 degrees) and lateralizing the glenoid component by using an angled bony or metallic augment of 8 to 10 mm provides optimal impingement-free ROM.
引用
收藏
页码:851 / 857
页数:7
相关论文
共 50 条
  • [31] Can surgeons optimize range of motion and reduce scapulohumeral impingements in reverse shoulder arthroplasty? A computational study
    Gauci, Marc-Olivier
    Chaoui, Jean
    Berhouet, Julien
    Jacquot, Adrien
    Walch, Gilles
    Boileau, Pascal
    SHOULDER & ELBOW, 2022, 14 (04) : 385 - 394
  • [32] Scapular Notching on Kinematic Simulated Range of Motion After Reverse Shoulder Arthroplasty Is Not the Result of Impingement in Adduction
    Laedermann, Alexandre
    Gueorguiev, Boyko
    Charbonnier, Caecilia
    Stimec, Bojan V.
    Fasel, Jean H. D.
    Zderic, Ivan
    Hagen, Jennifer
    Walch, Gilles
    MEDICINE, 2015, 94 (38)
  • [33] Range of motion after reverse shoulder arthroplasty: which combinations of humeral stem and glenosphere work best?
    Laedermann, Alexandre
    Collin, Philippe
    Denard, Patrick J.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2020, 15 (03): : 172 - 178
  • [34] Accuracy of Blueprint software in predicting range of motion 1 year after reverse total shoulder arthroplasty
    Baumgarten, Keith M.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (05) : 1088 - 1094
  • [35] The Real Post-Operative Range of Motion Differs from the Virtual Pre-Operative Planned Range of Motion in Reverse Shoulder Arthroplasty
    Berhouet, Julien
    Samargandi, Ramy
    Favard, Luc
    Turbillon, Celine
    Jacquot, Adrien
    Gauci, Marc-Olivier
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [36] Can a reverse shoulder arthroplasty be used to revise a failed primary reverse shoulder arthroplasty? REVISION REVERSE SHOULDER ARTHROPLASTY FOR FAILED REVERSE PROSTHESIS
    Wagner, E. R.
    Hevesi, M.
    Houdek, M. T.
    Cofield, R. H.
    Sperling, J. W.
    Sanchez-Sotelo, J.
    BONE & JOINT JOURNAL, 2018, 100B (11): : 1493 - 1498
  • [37] Reverse Shoulder Arthroplasty
    Nally, D.
    Molloy, A.
    Mullet, H.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2012, 181 : S187 - S188
  • [38] Reverse shoulder arthroplasty
    Smithers C.J.
    Young A.A.
    Walch G.
    Current Reviews in Musculoskeletal Medicine, 2011, 4 (4) : 183 - 190
  • [39] Reverse Shoulder Arthroplasty
    Jarrett, Claudius D.
    Brown, Brandon T.
    Schmidt, Christopher C.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2013, 44 (03) : 389 - +
  • [40] Reverse total shoulder arthroplasty for failed shoulder arthroplasty
    Patel, Deepan N.
    Young, Brett
    Onyekwelu, Ikemefuna
    Zuckerman, Joseph D.
    Kwon, Young W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (11) : 1478 - 1483