Automation of 4D flow MR image processing obtained by Cardiovascular Magnetic Resonance Imaging

被引:0
|
作者
Sandoval, Aaron Ponce [1 ]
Fuentes, Rodrigo Salas [2 ]
Flores, Julio Garcia [3 ]
Arancibia, Sergio Uribe [4 ]
Parraguez, Julio Sotelo [5 ]
机构
[1] Univ Valparaiso, Escuela Ingn Informat & iHlth, Valparaiso, Chile
[2] Univ Valparaiso, Escuela Ingn Biomed & iHlth, Valparaiso, Chile
[3] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[4] Monash Univ, Dept Med Imaging & Radiat Sci, Melbourne, Vic, Australia
[5] Univ Tecn Federico Santa Maria, Dept Informat, Santiago, Chile
关键词
Magnetic resonance imaging; 4D Flow MRI; Deep neural network; Medical image registration; Image Segmentation; MANAGEMENT;
D O I
10.1109/CLEI64178.2024.10700580
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Cardiac MRI makes it possible to explore blood flow in three orthogonal directions within the cardiovascular system, through an acquisition sequence called 4D flow MRI. This sequence has been used in recent years to diagnose complex cardiovascular diseases with high accuracy. However, it is limited by the long times required to obtain an accurate three-dimensional segmentation of a region of interest that allows quantification of a series of hemodynamic parameters. Segmentation of these images is challenging due to problems such as low signal-to-noise ratio, phase accumulation errors in the images, spatiotemporal resolution, and respiratory motion. To address this challenge, we propose a processing pipeline that uses a neural network for medical image registration and a cascade of semantic segmentation neural networks. This approach improves the segmentation of pulmonary artery branches and aortic sections into single or multiple cardiac phases, facilitating clinical analysis and research in cardiovascular disease.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] 4D flow cardiovascular magnetic resonance for monitoring of aortic valve repair in bicuspid aortic valve disease
    Lenz, Alexander
    Petersen, Johannes
    Riedel, Christoph
    Weinrich, Julius M.
    Kooijman, Hendrik
    Schoennagel, Bjoern P.
    Adam, Gerhard
    von Kodolitsch, Yskert
    Reichenspurner, Hermann
    Girdauskas, Evaldas
    Bannas, Peter
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [42] Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study
    Andreas Harloff
    Hanieh Mirzaee
    Thomas Lodemann
    Paul Hagenlocher
    Thomas Wehrum
    Judith Stuplich
    Anja Hennemuth
    Jürgen Hennig
    Sebastian Grundmann
    Werner Vach
    Journal of Cardiovascular Magnetic Resonance, 20
  • [43] Left atrial 4D flow cardiovascular magnetic resonance: a reproducibility study in sinus rhythm and atrial fibrillation
    Marco Spartera
    Guilherme Pessoa-Amorim
    Antonio Stracquadanio
    Adam Von Ende
    Alison Fletcher
    Peter Manley
    Stefan Neubauer
    Vanessa M. Ferreira
    Barbara Casadei
    Aaron T. Hess
    Rohan S. Wijesurendra
    Journal of Cardiovascular Magnetic Resonance, 23
  • [44] Subclinical Flow Inefficiencies in Non-Obstructive Hypertrophic Cardiomyopathy Subgroups Revealed by 4D Flow Cardiovascular Magnetic Resonance
    Pola, Karin
    Ashkir, Zakariye
    Myerson, Saul G.
    Arheden, Hakan
    Watkins, Hugh
    Neubauer, Stefan
    Arvidsson, Per M.
    Raman, Betty
    CIRCULATION, 2023, 148
  • [45] Blood flow visualization from 4D flow Magnetic Resonance Imaging using the ISO X3D standard
    Arbelaiz, Ander
    Bobeda, Javier
    Garcia, Sara
    Ruiz-Cabello, Jesus
    Garcia-Cosio, M. Dolores
    Lopez-Linares, Karen
    Posada, Jorge
    29TH INTERNATIONAL ACM CONFERENCE ON 3D WEB TECHNOLOGY, WEB3D 2024, 2024,
  • [46] Tricuspid flow and regurgitation in congenital heart disease and pulmonary hypertension: comparison of 4D flow cardiovascular magnetic resonance and echocardiography
    Mieke M. P. Driessen
    Marjolijn A. Schings
    Gertjan Tj Sieswerda
    Pieter A. Doevendans
    Erik H. Hulzebos
    Marco C. Post
    Repke J. Snijder
    Jos J. M. Westenberg
    Arie P. J. van Dijk
    Folkert J. Meijboom
    Tim Leiner
    Journal of Cardiovascular Magnetic Resonance, 20
  • [47] Tricuspid flow and regurgitation in congenital heart disease and pulmonary hypertension: comparison of 4D flow cardiovascular magnetic resonance and echocardiography
    Driessen, Mieke M. P.
    Schings, Marjolijn A.
    Sieswerda, Gertjan Tj
    Doevendans, Pieter A.
    Hulzebos, Erik H.
    Post, Marco C.
    Snijder, Repke J.
    Westenberg, Jos J. M.
    van Dijk, Arie P. J.
    Meijboom, Folkert J.
    Leiner, Tim
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [48] 4D flow imaging with MRI
    Stankovic, Zoran
    Allen, Bradley D.
    Garcia, Julio
    Jarvis, Kelly B.
    Markl, Michael
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (02) : 173 - 192
  • [49] Complete Intracranial Arterial and Venous Blood Flow Evaluation with 4D Flow MR Imaging
    Hope, M. D.
    Purcell, D. D.
    Hope, T. A.
    von Morze, C.
    Vigneron, D. B.
    Alley, M. T.
    Dillon, W. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (02) : 362 - 366
  • [50] Accelerating 4D image reconstruction for magnetic resonance-guided radiotherapy
    Lecoeur, Bastien
    Barbone, Marco
    Gough, Jessica
    Oelfke, Uwe
    Luk, Wayne
    Gaydadjiev, Georgi
    Wetscherek, Andreas
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27