Quantitative analysis of protective Kirschner wire diameters in lateral opening wedge distal femoral osteotomy: A finite element study

被引:0
|
作者
Baris, Alican [1 ]
Ozmen, Emre [1 ]
Circi, Esra [1 ]
Yuksel, Serdar [1 ]
Beytemur, Ozan [2 ]
机构
[1] Istanbul Phys Med & Rehabil Training & Res Hosp, Dept Orthoped & Traumatol, Istanbul, Turkiye
[2] Bagcilar Training & Res Hosp, Dept Orthoped & Traumatol, Istanbul, Turkiye
来源
JOINT DISEASES AND RELATED SURGERY | 2025年 / 36卷 / 01期
关键词
Biomechanics; distal femoral osteotomy; finite element analysis; hinge fracture; protective K-wire; FRACTURE; BONE;
D O I
10.52312/jdrs.2025.1806
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study aims to investigate quantitatively the protective effect of a 1.6-mm or a 2.5-mm Kirschner wire (K-wire) on the medial hinge at different gap distances through finite element analysis (FEA) and to establish whether using a 2.5-mm K-wire can offer benefits compared to a 1.6-mm in preventing medial hinge fractures. Materials and methods: Between June 2024 and July 2024, three different models simulating a lateral opening wedge (LOW) osteotomy of the distal femur were created from a femoral computed tomography (CT) scan of a 36-year-old male patient: no K-wire (Model I), 1.6-mm K-wire (Model II), and 2.5-mm K-wire (Model III). Finite element analysis was performed to simulate 7- to 13-mm gaps at the osteotomy site. Loads, principal stress, strain, and equivalent stress were analyzed around the medial hinge. Results: Model I required 123.0 +/- 5.2 N, Model II required 181.7 +/- 12.2 N, and Model III required 228.7 +/- 13.6 N (p<0.001). Cracked shell elements were the lowest in Model II and the highest in Model I. While the average equivalent/yield stress ratio was not significantly lower in Model II compared to Model III (87.0 +/- 10.9% vs. 92.7 +/- 12.1%), the maximum equivalent/yield stress ratio values in Model II were significantly lower than both Model I and Model III (1206.2 +/- 138.3% vs. 1836.2 +/- 165.4% and 1689.1 +/- 404.0%, respectively), suggesting a superior dispersion of forces. Conclusion: Using a 1.6-mm K-wire during LOW osteotomy of the distal femur provides a balance between structural reinforcement and stress distribution, significantly improving stability and reducing the risk of medial hinge fractures compared to a 2.5-mm K-wire or no K-wire. The 1.6-mm K-wire optimizes stress dispersion, making it the preferred choice for surgical planning in lateral opening wedge distal femoral osteotomy.
引用
收藏
页码:97 / 106
页数:10
相关论文
共 50 条
  • [31] Clinical Effect of Isolated Lateral Closing Wedge Distal Femoral Osteotomy Compared to Medial Opening Wedge High Tibial Osteotomy for the Correction of Varus Malalignment: A Propensity Score-Matched Analysis
    Rupp, Marco-Christopher
    Lindner, Felix
    Winkler, Philipp W.
    Muench, Lukas N.
    Mehl, Julian
    Imhoff, Andreas B.
    Siebenlist, Sebastian
    Feucht, Matthias J.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2023, 51 (02): : 437 - 445
  • [32] Finite element analysis of Kirschner wire fixation for lateral condyle fracture in children in the sagittal plane
    Bai, Huanan
    Lu, Qingda
    Liang, Xiaoju
    Wang, Xiaoming
    Yang, Yating
    Wang, Huan
    Wang, Jiaju
    Jie, Qiang
    FRONTIERS IN PEDIATRICS, 2023, 11
  • [33] CORR InsightsA®: Lateral Opening-wedge Distal Femoral Osteotomy: Pain Relief, Functional Improvement, and Survivorship at 5 Years
    Maak, Travis G.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (06) : 2016 - 2018
  • [34] Finite element analysis confirms the optimal apex position in medial opening wedge high tibial osteotomy to avoid lateral hinge fracture
    Osmani, Humza T.
    Gupta, Radhika
    Earl, Rosemary
    Tomaszczyk, Stanislaw
    Turmezei, Tom
    Segal, Neil A.
    Sutcliffe, Michael
    Melton, Joel
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (04)
  • [35] Outcomes of Distal Femoral Osteotomy for Valgus Malalignment: A Systematic Review and Meta-analysis of Closing Wedge Versus Opening Wedge Techniques
    Diaz, Connor C.
    Lavoie-Gagne, Ophelie Z.
    Knapik, Derrick M.
    Korrapati, Avinaash
    Chahla, Jorge
    Forsythe, Brian
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2023, 51 (03): : 798 - 811
  • [36] Soft Tissue Stabilization of the Hinge Position for Lateral Closing-Wedge Distal Femoral Osteotomy: An Anatomic Study
    Oda, Taiga
    Maeyama, Akira
    Ishimatsu, Tetsuro
    Tachibana, Katsuro
    Yoshimitsu, Kengo
    Yamamoto, Takuaki
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2024, 12 (03)
  • [37] Hinge location and apical drill holes in opening wedge high tibial osteotomy: A finite element analysis
    Bostrom, Anna
    Amin, Anish K.
    Macpherson, Gavin J.
    Pankaj, Pankaj
    Scott, Chloe E. H.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (03) : 628 - 636
  • [38] Biomechanical Comparison of Uniplanar versus Biplanar Lateral Opening-wedge Distal Femoral Osteotomy Techniques in Terms of Risk for Medial Hinge Fracture
    Yildirim, Cem
    Demirel, Mehmet
    Ekinci, Mehmet
    Ozturk, Simge
    Bozdag, Sureyya Ergun
    JOURNAL OF KNEE SURGERY, 2024, 37 (09) : 623 - 630
  • [39] Optimal hinge level in opening wedge high tibial osteotomy: Biomechanical analysis using finite element method
    Kyung, Min Gyu
    Bae, Tae Soo
    Baek, Hyeong Ho
    Chang, Moon Jong
    Kim, Tae Woo
    Kang, Seung-Baik
    CLINICAL BIOMECHANICS, 2023, 107
  • [40] Assessing the Local Mechanical Environment in Medial Opening Wedge High Tibial Osteotomy Using Finite Element Analysis
    Pauchard, Yves
    Ivanov, Todor G.
    McErlain, David D.
    Milner, Jaques S.
    Giffin, J. Robert
    Birmingham, Trevor B.
    Holdsworth, David W.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (03):