Phase volume fraction measurement of horizontal gas-liquid two-phase flow based on near-infrared absorption

被引:0
|
作者
Kong, Weihang [1 ,2 ]
Zhao, Xiting [1 ]
Li, Peiyu [1 ]
Zhang, Hengheng [1 ]
Li, Yang [3 ]
Li, Shaohua [1 ]
机构
[1] Yanshan Univ, Sch Informat Sci & Engn, Qinhuangdao 066004, Peoples R China
[2] Hebei Key Lab Comp Virtual Technol & Syst Integrat, Qinhuangdao 066004, Peoples R China
[3] SINOPEC, Shengli Oilfield Co, Reservoir Performance Monitoring Ctr, Dongying 257000, Peoples R China
关键词
near-infrared absorption spectroscopy; phase volume fraction measurement; horizontal gas-liquid two-phase flow; BACKLIGHT IMAGING TOMOGRAPHY; WATER; SPECTROSCOPY; HOLDUP; SLUG;
D O I
10.1088/1361-6501/adbde6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to measure the phase volume fraction of shale gas-liquid two-phase flow, this paper designs a novel phase volume fraction measurement method based on near-infrared absorption. Firstly, we analyze the measurement mechanism of phase volume fraction based on the absorption characteristics of near-infrared spectroscopy, and determine the specific absorption wavelength for the gas and liquid phases. Then, we design a near-infrared sensor for the phase volume fraction measurement of gas-liquid two-phase flow, and optimize its structure by changing the parameters of the sensor lens through ZEMAX simulation to obtain the optimal near-infrared transmitting and receiving sensor. Finally, through establishing the simulation experiment platform of gas-liquid two-phase flow, we conduct the static and dynamic experiments under different working conditions, so as to establish the phase volume fraction calculation model. The results show that the optimized near-infrared sensor can be applied to the phase volume fraction measurement of gas-liquid two-phase flow. For static experiments, when the pressure is lower than 800 kpa, the measurement error of the wavelength of 980 nm near-infrared sensor is within +/- 4% for liquid volume fraction of 0%-100%. The measurement error of the wavelength of 1650 nm near-infrared sensor is within +/- 4% for liquid volume fraction of 0%-25%. For dynamic experiments, the measurement error of the developed sensor is within +/- 7% for liquid volume fraction.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Influence of gravity on gas-liquid two-phase flow in horizontal pipes
    Liu, Xiangdong
    Chen, Yongping
    Shi, Mingheng
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2012, 41 : 23 - 35
  • [22] Characterization of the horizontal gas-liquid two-phase flow patterns using acoustic measurement techniques
    Zhao, Nan-Nan
    Feng, Jian-Jun
    Zhu, Guo-Jun
    Wu, Guang-Kuan
    Luo, Xing-Qi
    PHYSICS OF FLUIDS, 2025, 37 (01)
  • [23] Research on void fraction of gas-liquid two-phase flow based on COMSOL and MATLAB
    Su, Liang
    Song, Zhi-Ping
    Wang, Bao-Shou
    Ding, Li
    Chuan Bo Li Xue/Journal of Ship Mechanics, 2013, 17 (05): : 460 - 467
  • [24] Visualization and void fraction measurement of gas-liquid two-phase flow in plate heat exchanger
    Asano, H
    Takenaka, N
    Fujii, T
    Maeda, N
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (04) : 707 - 713
  • [25] Quantitative measurement of void fraction distributions in gas-liquid two-phase flow by neutron radiography
    Takenaka, N
    Kawano, S
    Matsumoto, A
    ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 1356 - 1360
  • [26] A New Void Fraction Measurement Method for Gas-Liquid Two-Phase Flow in Small Channels
    Li, Huajun
    Ji, Haifeng
    Huang, Zhiyao
    Wang, Baoliang
    Li, Haiqing
    Wu, Guohua
    SENSORS, 2016, 16 (02)
  • [27] A new contactless impedance sensor for void fraction measurement of gas-liquid two-phase flow
    Ji, Haifeng
    Chang, Ya
    Huang, Zhiyao
    Wang, Baoliang
    Li, Haiqing
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (12)
  • [28] Investigation on void fraction of gas-liquid two-phase flow in horizontal pipe under fluctuating vibration
    Zhou, Yunlong
    Ran, Yiwen
    Liu, Qichao
    Zhang, Shibo
    NUCLEAR ENGINEERING AND DESIGN, 2025, 431
  • [29] Void fraction measurement of gas-liquid two-phase flow based on C4D technique
    Wang, Lei
    Huang, Zhiyao
    Wang, Baoliang
    Ji, Haifeng
    Li, Haiqing
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 2331 - 2334
  • [30] Void Fraction Measurement of Gas-Liquid Two-Phase Flow in Mini-Pipe Based on Image Sequence
    Ji, Haifeng
    Jiang, Bei
    Huang, Zhiyao
    Wang, Baoliang
    Li, Haiqing
    2013 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST 2013), 2013, : 138 - 141