Flow-Injection Amperometric Detection of Tetracycline in Honey Using an Electrode Modified with Gold, Palladium, and Reduced Graphene Oxide

被引:0
|
作者
L. G. Shaidarova [1 ]
A. A. Pozdnyak [1 ]
A. V. Gedmina [1 ]
I. A. Chelnokova [1 ]
M. A. Ziganshin [1 ]
H. C. Budnikov [1 ]
机构
[1] Kazan (Volga Region) Federal University,
关键词
modified electrodes; gold and palladium binary system; reduced graphene oxide; electrooxidation of tetracycline; flow-injection amperometric determination of tetracycline;
D O I
10.1134/S1061934824701648
中图分类号
学科分类号
摘要
引用
收藏
页码:161 / 168
页数:7
相关论文
共 50 条
  • [41] Amperometric immunoassay for the detection of Salmonella pullorum using a screen - printed carbon electrode modified with gold nanoparticle-coated reduced graphene oxide and immunomagnetic beads
    Jianfeng Fei
    Wenchao Dou
    Guangying Zhao
    Microchimica Acta, 2016, 183 : 757 - 764
  • [42] A cobalt oxide nanocubes interleaved reduced graphene oxide nanocomposite modified glassy carbon electrode for amperometric detection of serotonin
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Numan, Arshid
    Shahabuddin, Syed
    Alizadeh, Mandi
    Khiew, Poi Sim
    Chiu, Wee Siong
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 100 : 388 - 395
  • [43] Batch injection analysis with amperometric detection for fluoroquinolone determination in urine, pharmaceutical formulations, and milk samples using a reduced graphene oxide–modified glassy carbon electrode
    Lucas Vinícius de Faria
    Davi Marques de Farias
    Thalles Pedrosa Lisboa
    Maria Auxiliadora Costa Matos
    Rodrigo Alejandro Abarza Munoz
    Renato Camargo Matos
    Analytical and Bioanalytical Chemistry, 2022, 414 : 5309 - 5318
  • [44] Flow injection amperometric detection at enzyme-modified gold nanoelectrodes
    Delvaux, M
    Demoustier-Champagne, S
    Walcarius, A
    ELECTROANALYSIS, 2004, 16 (03) : 190 - 198
  • [45] Flow-Injection Amperometric Determination of Urine Glucose Using Platinum Electrode Modified with Nafion® and Saccharide Substitued Polypyrrole
    Yasuzawa, Mikito
    Kitahara, Makoto
    Yabutani, Tomoki
    Motonaka, Junko
    BUNSEKI KAGAKU, 2009, 58 (11) : 941 - 944
  • [46] Amperometric detection of glucose using Prussian blue-graphene oxide modified platinum electrode
    Mohan, A. M. Vinu
    Aswini, K. K.
    Starvin, A. Maria
    Biju, V. M.
    ANALYTICAL METHODS, 2013, 5 (07) : 1764 - 1770
  • [47] Amperometric determination of L-cysteine using a glassy carbon electrode modified with palladium nanoparticles grown on reduced graphene oxide in a Nafion matrix
    Yusoff, Norazriena
    Rameshkumar, Perumal
    Noor, An'amt Mohamed
    Nay Ming Huang
    MICROCHIMICA ACTA, 2018, 185 (04)
  • [48] Amperometric determination of L-cysteine using a glassy carbon electrode modified with palladium nanoparticles grown on reduced graphene oxide in a Nafion matrix
    Norazriena Yusoff
    Perumal Rameshkumar
    An’amt Mohamed Noor
    Nay Ming Huang
    Microchimica Acta, 2018, 185
  • [49] Electrochemical study and flow-injection amperometric detection of trace NO2 at CuPtCl6 chemically modified electrode
    Pei, JH
    Li, XY
    TALANTA, 2000, 51 (06) : 1107 - 1115
  • [50] Flow injection indirect amperometric detection of ammonium ions using a clinoptilolite-modified electrode
    Walcarius, A.
    Vromman, V.
    Bessiere, J.
    Sensors and Actuators, B: Chemical, 1999, 56 (01): : 136 - 143