Assessment of Emphysema on X-ray Equivalent Dose Photon-Counting Detector CT Evaluation of Visual Scoring and Automated Quantification Algorithms

被引:1
|
作者
Kerber, Bjarne [1 ]
Ensle, Falko [1 ]
Kroschke, Jonas [1 ]
Strappa, Cecilia [2 ]
Larici, Anna Rita [2 ,3 ]
Frauenfelder, Thomas [1 ]
Jungblut, Lisa [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Zurich, Switzerland
[2] Fdn Policlin Univ A Gemelli IRCCS, Adv Radiol Ctr, Dept Diagnost Imaging & Oncol Radiotherapy, Rome, Italy
[3] Univ Cattolica Sacro Cuore, Dept Radiol & Hematol Sci, Sect Radiol, Rome, Italy
关键词
photon-counting detector CT; emphysema; scoring method; computer-assisted image analysis; computer-assisted image interpretations; thorax; radiation dosage; artificial intelligence; OBSTRUCTIVE PULMONARY-DISEASE; CHEST CT; MORPHOMETRY;
D O I
10.1097/RLI.0000000000001128
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to evaluate the feasibility and efficacy of visual scoring, low-attenuation volume (LAV), and deep learning methods for estimating emphysema extent in x-ray dose photon-counting detector computed tomography (PCD-CT), aiming to explore future dose reduction potentials. MethodsOne hundred one prospectively enrolled patients underwent noncontrast low- and chest x-ray dose CT scans in the same study using PCD-CT. Overall image quality, sharpness, and noise, as well as visual emphysema pattern (no, trace, mild, moderate, confluent, and advanced destructive emphysema; as defined by the Fleischner Society), were independently assessed by 2 experienced radiologists for low- and x-ray dose images, followed by an expert consensus read. In the second step, automated emphysema quantification was performed using an established LAV algorithm with a threshold of -950 HU and a commercially available deep learning model for automated emphysema quantification. Automated estimations of emphysema extent were converted and compared with visual scoring ratings. ResultsX-ray dose scans exhibited a significantly lower computed tomography dose index than low-dose scans (low-dose: 0.66 +/- 0.16 mGy, x-ray dose: 0.11 +/- 0.03 mGy, P < 0.001). Interreader agreement between low- and x-ray dose for visual emphysema scoring was excellent (kappa = 0.83). Visual emphysema scoring consensus showed good agreement between low-dose and x-ray dose scans (kappa = 0.70), with significant and strong correlation (Spearman rho = 0.79). Although trace emphysema was underestimated in x-ray dose scans, there was no significant difference in the detection of higher-grade (mild to advanced destructive) emphysema (P = 0.125) between the 2 scan doses. Although predicted emphysema volumes on x-ray dose scans for the LAV method showed strong and the deep learning model excellent significant correlations with predictions on low-dose scans, both methods significantly overestimated emphysema volumes on lower quality scans (P < 0.001), with the deep learning model being more robust. Further, deep learning emphysema severity estimations showed higher agreement (kappa = 0.65) and correlation (Spearman rho = 0.64) with visual scoring for low-dose scans than LAV predictions (kappa = 0.48, Spearman rho = 0.45). ConclusionsThe severity of emphysema can be reliably estimated using visual scoring on CT scans performed with x-ray equivalent doses on a PCD-CT. A deep learning algorithm demonstrated good agreement and strong correlation with the visual scoring method on low-dose scans. However, both the deep learning and LAV algorithms overestimated emphysema extent on x-ray dose scans. Nonetheless, x-ray equivalent radiation dose scans may revolutionize the detection and monitoring of disease in chronic obstructive pulmonary disease patients.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [31] X-ray photon-counting detector based on a micro-channel plate for pulsar navigation
    Chen, Baomei
    Zhao, Baosheng
    Hu, Huijun
    Yan, Qiurong
    Sheng, Lizhi
    CHINESE OPTICS LETTERS, 2011, 9 (06)
  • [32] Novel Photon-Counting Energy-Resolving Ultra-Fast X-Ray Detector
    Ertosun, M. Guenhan
    Levin, Craig S.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [33] X-ray photon-counting detector based on a micro-channel plate for pulsar navigation
    陈宝梅
    赵宝升
    胡慧君
    鄢秋荣
    盛立志
    ChineseOpticsLetters, 2011, 9 (06) : 13 - 16
  • [34] Characterization of a Pixelated CdTe X-Ray Detector Using the Timepix Photon-Counting Readout Chip
    Ruat, Marie
    Ponchut, Cyril
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 2392 - 2401
  • [35] Evaluation of CT images in the very low x-ray exposure with a photon counting detector with a CdTe semiconductor
    Kaibuki, Futoshi
    Matsumoto, Mariko
    Ogawa, Koichi
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [36] Performance of virtual non-contrast images generated on clinical photon-counting detector CT for emphysema quantification: proof of concept
    Jungblut, Lisa
    Sartoretti, Thomas
    Kronenberg, Daniel
    Mergen, Victor
    Euler, Andre
    Schmidt, Bernhard
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Martini, Katharina
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1135):
  • [37] Image quality assessment of a photon counting detector in X-ray projection imaging
    Ghani, Muhammad U.
    Li, Yuhua
    Wu, Xizeng
    Liu, Hong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 939 : 83 - 88
  • [38] Energy Calibration of a Silicon-Strip Detector for Photon-Counting Spectral CT by Direct Usage of the X-ray Tube Spectrum
    Liu, Xuejin
    Chen, Han
    Bornefalk, Hans
    Danielsson, Mats
    Karlsson, Staffan
    Persson, Mats
    Xu, Cheng
    Huber, Ben
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 68 - 75
  • [39] Characteristic evaluation of a novel CdTe photon counting detector for X-ray imaging
    Cho, Hyo-Min
    Kim, Hee-Joung
    Ryu, Hyun-Ju
    Choi, Yu-Na
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (01) : 120 - 127
  • [40] Characteristic evaluation of a novel CdTe photon counting detector for X-ray imaging
    Hyo-Min Cho
    Hee-Joung Kim
    Hyun-Ju Ryu
    Yu-Na Choi
    Journal of the Korean Physical Society, 2013, 63 : 120 - 127