Sensitive LC-MS/MS Assay for Total Testosterone Quantification on Unit Resolution and High-Resolution Instruments

被引:0
|
作者
Wolken, Jill K. [1 ]
Peterson, Meghan M. [1 ]
Cao, Wenjing [1 ,2 ]
Challoner, Keith [1 ]
Jin, Zhicheng [1 ,2 ]
机构
[1] Univ Wisconsin Hosp & Clin, Madison, WI 53792 USA
[2] Univ Wisconsin Madison, Dept Pathol & Lab Med, 600 Highland Ave, Madison, WI 53792 USA
关键词
testosterone; multiple reaction monitoring; high-resolution mass spectrometry; assay harmonization; parallel reaction monitoring; TANDEM MASS-SPECTROMETRY; SERUM TESTOSTERONE; VALIDATION;
D O I
10.3390/jcm13237056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Testosterone is an androgenic hormone that plays important roles in both males and females. The circulating levels of total testosterone vary from 1 to 1480 ng/dL. High-throughput immunoassays often lack accuracy in lower concentration ranges (below 100 ng/dL), particularly when used for females or children. To address this limitation, we developed a total testosterone LC-MS/MS assay on three instruments. Methods: Sample preparation began with the dilution and conditioning of 200 mu L of serum. A supported liquid extraction cartridge was used to extract the analyte from biological matrices. Chromatographic separation was achieved using a C18 column with a runtime of 5 min per sample. This assay was validated on a Triple Quad 6500 and an API 4500 instrument. Results: Method validation was carried out according to the CLSI C62-ED2 guideline and our hospital protocol. The within-day coefficient of variation (CV) was less than 10% and the between-day CV was less than 15%. The assay had a limit of quantitation of 0.5 ng/dL with an analyte measure range of 2-1200 ng/dL. A comparison using Deming regression and Bland-Altman plots showed that this assay correlated well with a reference method. The results from the API 4500 and an Orbitrap were consistent with those from the TQ 6500. Both serum-separator tubes (BD) and serum-activator tubes were found to be suitable. Conclusions: We successfully developed and validated a robust total testosterone LC-MS/MS assay for routine clinical testing. This assay was harmonized across two triple quadrupole instruments and one high-resolution mass spectrometer.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Development and validation of a simple, selective, and sensitive LC-MS/MS assay for the quantification of remdesivir in human plasma
    Nguyen, Ryan
    Goodell, Jennifer C.
    Shankarappa, Priya S.
    Zimmerman, Sara
    Yin, Tyler
    Peer, Cody J.
    Figg, William D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1171
  • [22] Sensitive and specific LC-MS assay for quantification of digoxin in human plasma and urine
    Kirby, Brian J.
    Kalhorn, Tom
    Hebert, Mary
    Easterling, Tom
    Unadkat, Jashvant D.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 712 - 718
  • [23] SIMULTANEOUS QUANTIFICATION OF TESTOSTERONE AND ANDROSTENEDIONE IN HUMAN SERUM USING LC-MS/MS
    Joos, E.
    Van Bocxlaer, J.
    Vandermarliere, M.
    Croes, K.
    ACTA CLINICA BELGICA, 2010, 65 (03): : 215 - 215
  • [24] Featuring ultimate sensitivity of high-resolution LC-MS analysis of phenolics in rat plasma
    Vlckova, Hana Kocova
    Catapano, Maria Carmen
    Mitasik, Lucia
    Kotland, Ondrej
    Nejmanova, Iveta
    Pourova, Jana
    Mladenka, Ptemysl
    Novakova, Lucie
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (09) : 1904 - 1912
  • [25] Expedient data mining for nontargeted high-resolution LC-MS profiles of biological samples
    Hnatyshyn, Serhiy
    Shipkova, Petia
    Sanders, Mark
    BIOANALYSIS, 2013, 5 (10) : 1195 - 1210
  • [26] AMDORAP: Non-targeted metabolic profiling based on high-resolution LC-MS
    Takahashi, Hiroki
    Morimoto, Takuya
    Ogasawara, Naotake
    Kanaya, Shigehiko
    BMC BIOINFORMATICS, 2011, 12
  • [27] AMDORAP: Non-targeted metabolic profiling based on high-resolution LC-MS
    Hiroki Takahashi
    Takuya Morimoto
    Naotake Ogasawara
    Shigehiko Kanaya
    BMC Bioinformatics, 12
  • [28] Simple data-reduction method for high-resolution LC-MS data in metabolomics
    Scheltema, R. A.
    Decuypere, S.
    Dujardin, J. C.
    Watson, D. G.
    Jansen, R. C.
    Breitling, R.
    BIOANALYSIS, 2009, 1 (09) : 1551 - 1557
  • [29] Histamine quantification in human plasma using high resolution accurate mass LC-MS technology
    Laurichesse, Mathieu
    Gicquel, Thomas
    Moreau, Caroline
    Tribut, Olivier
    Tarte, Karin
    Morel, Isabelle
    Bendavid, Claude
    Ame-Thomas, Patricia
    CLINICAL BIOCHEMISTRY, 2016, 49 (1-2) : 111 - 116
  • [30] Quantification of free and total sialic acid excretion by LC-MS/MS
    van der Ham, Maria
    Prinsen, Berthil H. C. M. T.
    Huijmans, Jan G. M.
    Abeling, Nicolaas G. G. M.
    Dorland, Bert
    Berger, Ruud
    de Koning, Tom J.
    de Sain-van der Velden, Monique G. M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 848 (02): : 251 - 257