Loss of insulation vacuum tests on an EuXFEL cryomodule

被引:0
|
作者
Barbanotti, S. [1 ]
Boeckmann, T. [1 ]
Bozhko, Y. [1 ]
Jensch, K. [1 ]
Klos, R. [1 ]
Ramalingam, R. [1 ]
Dhillon, A. K. [1 ]
Schnautz, T. [1 ]
Sellmann, D. [1 ]
机构
[1] Deutsch Elektronen Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany
关键词
D O I
10.1088/1757-899X/1301/1/012046
中图分类号
O414.1 [热力学];
学科分类号
摘要
Many Free Electron Lasers (FEL) are nowadays based on linear superconducting accelerators (linacs). The typical layout of such a linac consists of a number of cryomodules (CMs) arranged in strings. Each cryogenic circuit in a string is protected by safety valves (SVs) in case of failure of the system or a catastrophic event. A typical worst-case scenario considers the venting of the insulation vacuum, causing a fast and uncontrolled warm up of the cryogenic circuits. Such venting can for example take place across a pump port belonging to a string. The amount of heat deposited on each circuit is a very important parameter to correctly size the safety devices. This paper describes the tests performed at DESY on an EuXFEL cryomodule to evaluate the heat input to the three cryogenic circuits of the CM while venting the insulation vacuum. Test results are given with a particular focus of their application to long strings.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Experimental study on the storage performance of high-vacuum-multilayer-insulation tank after sudden, catastrophic loss of insulating vacuum
    G. F. Xie
    X. D. Li
    R. S. Wang
    Heat and Mass Transfer, 2012, 48 : 757 - 766
  • [42] VACUUM WEIGHT-LOSS AND CONTAMINATION TESTS OF SOME MATERIALS FOR SPACE APPLICATIONS
    POEHLMAN.HC
    VACUUM, 1968, 18 (03) : 164 - &
  • [43] Analytical study of insulation characteristics of thermal batteries with vacuum insulation
    Kim C.-H.
    Choi J.-H.
    Park S.-Y.
    Lee H.-C.
    Lee S.-J.
    Kim G.
    Defect and Diffusion Forum, 2021, 412 : 141 - 147
  • [44] INTERMEDIATE QUALITY CONTROL TESTS IN THE DEVELOPMENT OF A SUPERCONDUCTING RF CRYOMODULE FOR CW OPERATION
    Pattalwar, S.
    Jones, T.
    Strachan, J.
    Bate, R.
    Davis, P.
    McIntosh, P.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 1583 - 1589
  • [45] SPECIFICATION AND DESIGN OF A 2 K HELIUM SYSTEM FOR CRYOMODULE AND CAVITY TESTS AT FRIB
    Waltz, C.
    Bricker, S.
    Compton, C.
    Fila, A.
    Johnson, M.
    Jones, S.
    Laumer, H.
    McCartney, A.
    Popielarski, J.
    Popielarski, L.
    Weisend, J. G., II
    Wlodarczak, J.
    Zeller, A.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 1092 - 1099
  • [46] Insulation tests with crotin and anticrotin
    Fujiwara, K
    BIOCHEMISCHE ZEITSCHRIFT, 1923, 140 : 132 - 139
  • [47] Characterization of insulators for electric insulation in vacuum
    Damamme, G
    LeGressus, C
    ISDEIV - XVIITH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, VOLS I AND II, 1996, : 405 - 409
  • [48] ETICS WITH INTEGRATED VACUUM INSULATION PANELS
    Kubina, Libor
    CESB 10: CENTRAL EUROPE TOWARDS SUSTAINABLE BUILDING - FROM THEORY TO PRACTICE, 2010, : 407 - 410
  • [49] FLAT PANEL VACUUM THERMAL INSULATION
    STRONG, HM
    BUNDY, FP
    BOVENKERK, HP
    JOURNAL OF APPLIED PHYSICS, 1960, 31 (01) : 39 - 50
  • [50] NOVEL VACUUM FURNACE INSULATION SYSTEM
    BENEDICT, J