Assessment of superior mesenteric vascular flow quantitation in children using four-dimensional flow magnetic resonance imaging: A feasibility study

被引:0
|
作者
Leesmidt, Kantheera [1 ]
Vakil, Parmede [2 ]
Verstraete, Sofia [3 ]
Liu, Amanda R. [4 ]
Durand, Rachelle [5 ]
Courtier, Jesse [5 ]
机构
[1] Naresuan Univ, Fac Med, Dept Radiol, Phitsanulok 65000, Thailand
[2] OHSU, Dept Radiol, Portland, OR 97239 USA
[3] Univ Calif San Francisco, Dept Pediat, Div Pediat Gastroenterol, San Francisco, CA 94127 USA
[4] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94127 USA
[5] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, Benioff Childrens Hosp, 1975 4th St C1758P, San Francisco, CA 94158 USA
来源
WORLD JOURNAL OF RADIOLOGY | 2025年 / 17卷 / 02期
关键词
Four-dimensional flow magnetic resonance imaging; Superior mesenteric artery; Superior mesenteric vein; Bowel disease; Mesenteric vessel flow analysis; 4D FLOW;
D O I
10.4329/wjr.v17.i2.99333
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND Four-dimensional (4D) flow magnetic resonance imaging (MRI) is used as a noninvasive modality for assessing hemodynamic information with neurovascular and body applications. The application of 4D flow MRI for assessment of bowel disease in children has not been previously described. AIM To determine feasibility of superior mesenteric venous and arterial flow quantitation in pediatric patients using 4D flow MRI. METHODS Nine pediatric patients (7-14 years old, 5 male and 4 female) with history or suspicion of bowel pathology, who underwent magnetic resonance (MR) enterography with 4D flow MR protocol from November 2022 to October 2023. Field strength/sequence: 3T MRI using 4D flow MR protocol. Flow velocity and peak speed measurements were performed by two diagnostic radiologists placing the region of interest in perpendicular plane to blood flow on each cross section of superior mesenteric artery (SMA) and superior mesenteric vein (SMV) at three predetermined levels. Bland-Altman analysis, showed good agreement of flow velocity and peak speed measurements of SMV and SMA between two readers. RESULTS Mean SMV flow velocity increased from proximal to mid to distal (0.14 L/minute, 0.17 L/minute, 0.22 L/minute respectively). Mean SMA flow velocity decreased from proximal to mid to distal (0.35 L/minute, 0.27 L/minute, 0.21 L/minute respectively). Observed agreement was good for flow velocity measurements of SMV (mean bias -0.01 L/minute and 95% limits of agreement, -0.09 to 0.08 L/minute) and SMA (mean bias -0.03 L/minute and 95% limits of agreement, -0.23 to 0.17 L/minute) between two readers. Good agreement for peak speed measurements of SMV (mean bias -1.2 cm/second and 95% limits of agreement, -9.4 to 7.0 cm/second) and SMA (mean bias -3.2 cm/second and 95% limits of agreement, -31.4 to 24.9 cm/second). CONCLUSION Flow quantitation using 4D Flow is feasible to provide hemodynamic information for SMV and SMA in children.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Four-dimensional flow cardiac magnetic resonance assessment of left ventricular diastolic function
    Ashkir, Zakariye
    Myerson, Saul
    Neubauer, Stefan
    Carlhall, Carl-Johan
    Ebbers, Tino
    Raman, Betty
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [22] Four-dimensional velocity encoded magnetic resonance imaging for more accurate blood flow quantification in complex flow
    Sarah Nordmeyer
    Eugénie Riesenkampff
    Felix Berger
    Titus Kuehne
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [23] Four-dimensional, flow-sensitive magnetic resonance imaging of blood flow patterns in thoracic aortic dissections
    Francois, Christopher J.
    Markl, Michael
    Schiebler, Mark L.
    Niespodzany, Eric
    Landgraf, Benjamin R.
    Schlensak, Christian
    Frydrychowicz, Alex
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (05): : 1359 - 1366
  • [24] The calculation method of blood flow pressure based on four-dimensional flow magnetic resonance imaging and deep learning
    Tao, Chunhao
    Han, Yanjing
    Du, Tianming
    Zhang, Yanping
    Jin, Long
    Zhang, Hanbing
    Chen, Shiliang
    Wang, Qian
    Wu, Wei
    Qiao, Aike
    PHYSICS OF FLUIDS, 2024, 36 (09)
  • [25] Four-Dimensional Blood Flow Analysis in Patients with Dilated Cardiomyopathy: A Cardiac Magnetic Resonance Flow Study
    Nabeta, Takeru
    Kakizaki, Ryota
    Itatani, Keiichi
    Ako, Junya
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (09) : S177 - S177
  • [26] FLOW QUANTITATION USING MAGNETIC-RESONANCE IMAGING
    PICKENS, DR
    PRICE, RR
    KULKARNI, MV
    MARTIN, V
    MAZER, M
    PARTAIN, CL
    JAMES, AE
    INVESTIGATIVE RADIOLOGY, 1985, 20 (06) : S48 - S48
  • [27] Editorial for "Evaluation of Aortic Hemodynamics Using Four-Dimensional Flow of Magnetic Resonance Imaging in Rabbits with Liver Fibrosis"
    Zhang, Xinyuan
    Xu, Ke
    Guo, Yingkun
    Xu, Huayan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (06) : 2613 - 2614
  • [28] Four-dimensional flow magnetic resonance imaging: Just beautiful pictures or clinical relevant analysis?
    Grabenwoger, Martin
    Winkler, Bernhard
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (06): : 2252 - 2253
  • [29] Four-Dimensional Flow Magnetic Resonance Imaging in the Evaluation of Intracardiac Oxygenation in an Infant With a Single Ventricle
    Kawamura, Junpei
    Ueno, Kentaro
    Takumi, Koji
    Yoshiura, Takashi
    Okamoto, Yasuhiro
    CIRCULATION JOURNAL, 2022, 86 (01) : 166 - 166
  • [30] Hemodynamic Assessment in Patients with One-and-a-Half Ventricle Repair Revealed by Four-Dimensional Flow Magnetic Resonance Imaging
    Sergio Uribe
    Pablo Bächler
    Israel Valverde
    Gérard R. Crelier
    Philipp Beerbaum
    Cristian Tejos
    Pablo Irarrazaval
    Pediatric Cardiology, 2013, 34 : 447 - 451