Evaluating glaucoma in myopic eyes: Challenges and opportunities

被引:1
|
作者
Jiravarnsirikul, Anuwat [1 ,2 ]
Belghith, Akram [1 ]
Rezapour, Jasmin [1 ,3 ]
Bowd, Christopher [1 ]
Moghimi, Sasan [1 ]
Jonas, Jost B. [4 ,5 ,6 ]
Christopher, Mark [1 ]
Fazio, Massimo A. [7 ,8 ]
Yang, Hongli [9 ]
Burgoyne, Claude F. [9 ]
Weinreb, Robert N. [1 ]
Zangwill, Linda M. [1 ]
机构
[1] Univ Calif San Diego, Shiley Eye Inst, Hamilton Glaucoma Ctr, Viterbi Family Dept Ophthalmol, 9500 Gilman Dr, La Jolla, CA 92093 USA
[2] Mahidol Univ, Fac Med, Dept Ophthalmol, Siriraj Hosp, Bangkok, Thailand
[3] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Ophthalmol, Mainz, Germany
[4] Hop Fdn Rothschild, Inst Francais Myopie, 44 Ave Mathurin Moreau, F-75019 Paris, France
[5] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[6] Privatpraxis Prof Jonas & Dr Panda Jonas, Heidelberg, Germany
[7] Univ Alabama Birmingham, Sch Med, Dept Ophthalmol & Vis Sci, Birmingham, AL USA
[8] Univ Alabama Birmingham, Sch Engn, Dept Biomed Engn, Birmingham, AL USA
[9] Devers Eye Inst, Legacy Res Inst, Opt Nerve Head Res Lab, Portland, OR USA
关键词
Glaucoma; Myopia; High myopia; Optic nerve head; Fundus photograph; Optical coherence tomography; Optical coherence tomography angiography; Visual field; OPTICAL COHERENCE TOMOGRAPHY; NERVE-FIBER-LAYER; PRIMARY OPEN-ANGLE; INNER PLEXIFORM LAYER; MACULAR GANGLION-CELL; VISUAL-FIELD DEFECTS; LAMINA-CRIBROSA DEFECTS; NORMAL-TENSION GLAUCOMA; CHOROIDAL MICROVASCULATURE DROPOUT; NEURORETINAL RIM THICKNESS;
D O I
10.1016/j.survophthal.2024.12.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The increasing global prevalence of myopia presents a significant public health concern, and growing evidence has demonstrated that myopia is a major risk factor for the development of open-angle glaucoma. Therefore, timely detection and management of glaucoma in myopic patients are crucial; however, identifying the structural alterations of glaucoma in the optic nerve head (ONH) and retinal tissues of myopic eyes using standard diagnostic tools such as fundus photography, optical coherence tomography (OCT), and OCT angiography (OCTA) presents challenges. Additionally, myopia-related perimetric defects can be confounded with glaucoma-related defects. We comprehensively examine the challenges encountered in evaluating glaucoma in myopic eyes through various diagnostic tools, including fundus photography, OCT of the ONH, retinal nerve fiber layer, and macular ganglion cell layer, OCTA, and perimetry. We also explore potential opportunities to address these challenges, providing insights for clinicians to effectively manage myopic glaucoma patients in clinical practice.
引用
收藏
页码:563 / 582
页数:20
相关论文
共 50 条
  • [31] Beta and Gamma Parapapillary Atrophy (PPA) Zone Areas in Myopic Eyes With and Without Glaucoma
    Voora, Rohith
    Moghadam, Mohamad
    Lee, Jason Han
    Bowd, Christopher
    Proudfoot, James
    Moghimi, Sasan
    Manalastas, Patricia Isabel C.
    Christopher, Mark
    Liebmann, Jeffrey M.
    Girkin, Christopher A.
    Weinreb, Robert N.
    Belghith, Akram
    Zangwill, Linda M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [32] Asymmetry Analysis of Macular Retinal Layers for Diagnosis of Early Glaucoma in Highly Myopic Eyes
    Yamada, Hiroshi
    Hangai, Masanori
    Nakano, Noriko
    Kimura, Yugo
    Akagi, Tadamichi
    Ikeda, Hanako Ohashi
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [33] Glaucoma Detection in Myopic Eyes: Structural and Vascular Assessment by Optic Coherence Tomography Methods
    Cakir, Ihsan
    Altan, Cigdem
    Yalcinkaya, Gulay
    Yayla, Gizem
    Alagoz, Nese
    Basgil Pasaoglu, Isil
    Yasar, Tekin
    JOURNAL OF GLAUCOMA, 2022, 31 (12) : 947 - 954
  • [34] Histomorphometry of the optic disc in highly myopic eyes with absolute secondary angle closure glaucoma
    Dichtl, A
    Jonas, JB
    Naumann, GOH
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (03) : 286 - 289
  • [35] Glaucoma Screening in Myopic Eyes Using Optical Coherence Tomography-based Scores
    Huebschmann, Lukas
    El-Nimri, Nevin W.
    Guzman, Anya
    Durbin, Mary
    Hou, Huiyuan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [36] The Characteristics of Lamina Cribrosa Defects in Myopic Eyes With and Without Open-Angle Glaucoma
    Han, Jong Chul
    Cho, Seok Ho
    Sohn, Dae Yong
    Kee, Changwon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (02) : 486 - 494
  • [37] The challenges of diagnosing glaucoma in myopic cases and the important role of Bruch's membrane opening-minimum rim width in the diagnosis of myopic glaucoma
    Celik, Gokhan
    Saricaoglu, Murat Sinan
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2025, 52
  • [38] Assessment of Optical Coherence Tomography Color Probability Codes in Myopic Glaucoma Eyes After Applying a Myopic Normative Database Reply
    Seol, Bo Ram
    Kim, Dong Myung
    Park, Ki Ho
    Jeoung, Jin Wook
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 184 : 192 - 193
  • [39] Optic Disc Change during Childhood Myopic Shift: Comparison between Eyes with an Enlarged Cup-To-Disc Ratio and Childhood Glaucoma Compared to Normal Myopic Eyes
    Park, Hae-Young Lopilly
    Kim, Sung Eum
    Park, Chan Kee
    PLOS ONE, 2015, 10 (07):
  • [40] Management Of Glaucoma In Developing Countries: Challenges And Opportunities For Improvement
    Delgado, Maria Fernanda
    Abdelrahman, Ahmed Mostafa
    Terahi, Malika
    Woll, Juan Jose Miro Quesada
    Cook, Felix Gil-Carrasco Colin
    Benharbit, Mohamed
    Boisseau, Sebastien
    Chung, Ernestine
    Hadjiat, Yacine
    Gomes, Jose A. P.
    CLINICOECONOMICS AND OUTCOMES RESEARCH, 2019, 11 : 591 - 604