Characterization of neutron spectrum at the neutron radiography of RSG-GAS reactor using a passive single-cylindrical neutron spectrometer

被引:0
|
作者
Tursinah, Rasito [1 ,2 ]
Permana, Sidik [1 ]
Su'ud, Zaki [1 ]
Maulana, Alan [2 ]
Rivai, Abu Khalid [2 ]
Subekti, Muhammad [3 ]
Suyatno [3 ]
Ramdhani, Achmad [3 ]
Akbar, Fahrurrozi [2 ]
Muslih, M. Refai [2 ]
Wahyudi [2 ]
Istanto [3 ]
Prakoso, Djoko [2 ]
Ramadhani, M. F. [2 ]
Laksono, Tri C. [3 ]
Bunawas [4 ]
机构
[1] Bandung Inst Technol, Nucl Sci & Engn Dept, Jl Ganeca 10, Bandung, Indonesia
[2] Natl Res & Innovat Agcy, Res Org Nucl Energy, BJ Habibie Sci & Technol Pk, Tangerang Selatan, Banten, Indonesia
[3] Natl Res & Innovat Agcy, Directorate Nucl Facil Management, BJ Habibie Sci & Technol Pk, Tangerang Selatan, Banten, Indonesia
[4] Nuklindolab, Plaza Ciputat Mas, Tangerang Selatan, Banten, Indonesia
关键词
Neutron spectrum; Tangential beam-tube; RSG-GAS; Neutron radiography; Single-moderator spectrometer; Passive detectors; 1ST CORE; CRITICALITY; SENSITIVITY; COLLIMATOR; FACILITY; DESIGN; BEAM; CODE;
D O I
10.1016/j.anucene.2025.111275
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Neutron spectrum characterization of RSG-GAS neutron radiography was carried out using a single-moderatorbased neutron spectrometer with a passive type Au and In activation foils neutron detector. The neutron spectrum was obtained using Unfolding Maxed-Gravel (UMG) technique based on the activity of 198Au and 116mIn after irradiation. The neutron spectrum obtained was then compared with the simulation results using the MCNPX 2.7 program. Neutron spectrum measurements using In foil provide flux values that are closer to the simulation results, there is a difference with the simulation of 25 %. The total neutron flux is (6.65 +/- 0.08) x 106 n/cm2 center dot s with thermal neutron of 83 %. The results of neutron spectrum characterization using measurements and simulations show that the RSG-GAS radiography neutron beam has a spectrum dominated by thermal neutrons with a flux of the order of 106 n/cm2 center dot s so it is very suitable as a thermal radiography neutron facility.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] MEASUREMENT OF FAST NEUTRON SPECTRUM IN A FAST REACTOR BY A 6LI SEMICONDUCTOR SPECTROMETER
    WINDSOR, ME
    WRIGHT, SB
    JOURNAL OF NUCLEAR ENERGY PARTS A AND B-REACTOR SCIENCE AND TECHNOLOGY, 1966, 20 (6PA-): : 465 - &
  • [42] Experimental characterization of the Advanced Liquid Hydrogen Cold Neutron Source spectrum of the NBSR reactor at the NIST Center for Neutron Research
    Cook, J. C.
    Barker, J. G.
    Rowe, J. M.
    Williams, R. E.
    Gagnon, C.
    Lindstrom, R. M.
    Ibberson, R. M.
    Neumann, D. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 792 : 15 - 27
  • [43] Neutron spectrometry and dosimetry study at two research nuclear reactors using Bonner sphere spectrometer (BSS), rotational spectrometer (ROSPEC) and cylindrical nested neutron spectrometer (NNS)
    Atanackovic, J.
    Matysiak, W.
    Witharana, S. S. Hakmana
    Aslam, I.
    Dubeau, J.
    Waker, A. J.
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 364 - 374
  • [44] Characterization of the Annular Core Research Reactor (ACRR) Neutron Radiography System Imaging Plane
    Kaiser, Krista
    Nowlen, K. Chantel
    DePriest, K. Russell
    ISRD 15 - INTERNATIONAL SYMPOSIUM ON REACTOR DOSIMETRY, 2016, 106
  • [45] PASSIVE NEUTRON SPECTROMETER AND DOSIMETER USING LIF = MG, TI THERMOLUMINESCENT DETECTORS
    SINGH, D
    BURGKHARDT, B
    PIESCH, E
    NUCLEAR INSTRUMENTS & METHODS, 1977, 142 (03): : 409 - 415
  • [46] Unfolding of the neutron spectrum in a nuclear reactor using genetic algorithms method
    El-Bouzaidi, Mohamed Drissi
    El Bardouni, T.
    Chham, E.
    El Hajjaji, O.
    Nouayti, A.
    Idrissi, Abdelghani
    El-Bakkari, K.
    NUCLEAR ENGINEERING AND DESIGN, 2024, 422
  • [47] Determination of α factor of epithermal neutron flux in Dalat reactor, Vietnam, based on neutron spectrum calculated using MCNP code
    Tran Van Hung
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 283 : 707 - 711
  • [48] Determination of α factor of epithermal neutron flux in Dalat reactor, Vietnam, based on neutron spectrum calculated using MCNP code
    Tran Van Hung
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 283 (03) : 707 - 711
  • [49] Neutron energy spectrum measurement using CLYC7-based compact neutron emission spectrometer in the Large Helical Device
    Sangaroon, S.
    Ogawa, K.
    Isobe, M.
    Kobayashi, M. I.
    Fujiwara, Y.
    Kamio, S.
    Yamaguchi, H.
    Seki, R.
    Nuga, H.
    Toyama, S.
    Miwa, M.
    Matsuyama, S.
    Takada, E.
    Murakami, S.
    Zhong, G. Q.
    Osakabe, M.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (12):
  • [50] An investigation on the improvement of neutron radiography system of the Tehran research reactor by using MCNPX simulations
    Amini, Moharram
    Zamzamian, Seyed Mehrdad
    Fadaei, Amir Hossein
    Gharib, Morteza
    Feghhi, Seyed Amir Hosein
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (10) : 3413 - 3420