Very High-Power Short-Duration Ablation for Atrial Fibrillation in Adults With Congenital Heart Disease

被引:0
|
作者
Lengauer, Sarah [1 ]
Erhard, Nico [1 ]
Popa, Miruna A. [1 ]
Telishevska, Marta [1 ]
Krafft, Hannah [1 ]
Bahlke, Fabian [1 ]
Englert, Florian [1 ]
Bourier, Felix [1 ]
Reents, Tilko [1 ]
Deisenhofer, Isabel [1 ]
Hessling, Gabriele [1 ]
机构
[1] TUM Univ Hosp, German Heart Ctr Munich, Dept Electrophysiol, Munich, Bavaria, Germany
关键词
adults with congenital heart disease; long-term outcome; paroxysmal and persistent atrial fibrillation; safety; very high-power short duration ablation; PULMONARY VEIN ISOLATION; CATHETER ABLATION; ARRHYTHMIAS; PREVALENCE; SAFETY;
D O I
10.1111/jce.16567
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionData regarding safety and long-term outcome of very high-power-short duration (vHPSD) ablation in adult congenital heart disease (ACHD) patients with paroxysmal or persistent atrial fibrillation (AF) are lacking.MethodsRetrospective observational single-center study. The data of 66 consecutive ACHD patients (mean age 60 +/- 12.8 years, 46% male) with mild (69.7%), moderate (22.7%), or complex (7.6%) congenital heart disease (CHD) who underwent ablation for paroxysmal (40.9%) or persistent AF (59.1%) were analyzed. Circumferential PVI was performed in all patients and additional substrate ablation in 79,4% of persistent AF patients using irrigated RF energy with vHPSD settings of 70 W/5-7 s or 60 W/7-10 s.ResultsMean procedure time was 123.6 +/- 42 min with a mean RF time of 18.19 +/- 10 min. No technique related adverse events occurred. Vascular access complications were detected in seven patients (10.6%) requiring intervention in four patients (6%). A median follow-up time of 491 days (IQR: 194-1054 days). Freedom from any atrial arrhythmia off antiarrhythmic drugs (AAD) at 1 year was present in 58% of patients (77.8% with paroxysmal AF, 43.6% with persistent AF).ConclusionvHPSD for ablation of paroxysmal or persistent AF in ACHD patients is safe and effective. Regardless of CHD complexity, no vHPSD ablation modality related complications occurred. Long-term outcome for paroxysmal AF after one ablation was excellent whereas results for persistent AF were limited.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Revisiting pulmonary vein stenosis after high-power short-duration radiofrequency ablation in patients with atrial fibrillation
    Kim, J.
    Kim, D.
    Park, J.
    Yu, H.
    Kim, T.
    Uhm, J.
    Joung, B.
    Lee, M.
    Park, H.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [42] High-power short-duration ablation with laser balloon
    Kondo, Yusuke
    Kajiyama, Takatsugu
    Nakano, Masahiro
    Kobayashi, Yoshio
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1690 - 1691
  • [43] Comparison of traditional radiofrequency ablation and high-power short-duration ablation in the treatment of atrial tachyarrhythmias
    Yakushev, A., V
    Paratsii, O. Z.
    ZAPOROZHYE MEDICAL JOURNAL, 2022, 24 (04) : 385 - 389
  • [44] Effectiveness and safety of high-power and short-duration ablation for cavotricuspid isthmus ablation in atrial flutter
    Kwon, Hee-Jin
    Lee, Seong Soo
    Park, Young Jun
    Park, Seung-Jung
    Park, Kyoung-Min
    Kim, June Soo
    On, Young Keun
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (09): : 941 - 946
  • [45] Meta-Analysis of Pulsed-Field Ablation Versus- High-Power Short-Duration Ablation for Atrial Fibrillation
    Xue, Jun
    Huang, Qunying
    Yu, Fuling
    Mao, Yinjun
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2025,
  • [46] Combined approach of high-power and very high-power, short-duration ablation in superior vena cava isolation
    Makita, Toshio
    Kuwahara, Taishi
    Takahashi, Kenta
    Oshio, Takuya
    Kadono, Kenta
    Oyagi, Yoshimi
    Ito, Yayoi
    Takahashi, Ryo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (11) : 2144 - 2152
  • [47] How an innovative catheter with temperature control and very high-power, short-duration ablation changed our approach to the treatment of persistent atrial fibrillation
    Volpato, Giovanni
    Compagnucci, Paolo
    Cipolletta, Laura
    Parisi, Quintino
    Valeri, Yari
    Santarelli, Giulia
    Colonnelli, Michela
    Casella, Michela
    Dello Russo, Antonio
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2023, 25 : C258 - C260
  • [48] Pulsed field vs very high-power short-duration radiofrequency ablation for atrial fibrillation: Results of a multicenter, real-world experience
    Dello Russo, Antonio
    Compagnucci, Paolo
    Anselmino, Matteo
    Schillaci, Vincenzo
    Campanelli, Francesca
    Ascione, Maria Rosaria
    Volpato, Giovanni
    Cipolletta, Laura
    Parisi, Quintino
    Valeri, Yari
    D'Angelo, Leonardo
    Chiariello, Paola
    Casella, Michela
    Solimene, Francesco
    HEART RHYTHM, 2024, 21 (09) : 1526 - 1536
  • [49] Safety and outcome of very if high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kottmaier, Marc
    Popa, Miruna
    Bourier, Felix
    Reents, Tilko
    Cifuentes, Jairo
    Semmler, Verena
    Telishevska, Martha
    Otgonbayar, Ulamnemekh
    Koch-Buettner, Katharina
    Lennerz, Carsten
    Bartkowiak, Marcin
    Kornmayer, Marielouise
    Rousseva, Elena
    Brkic, Amir
    Grebmer, Christian
    Kolb, Christoph
    Hessling, Gabriele
    Deisenhofer, Isabel
    EUROPACE, 2020, 22 (03): : 388 - 393
  • [50] Posterior wall ablation for persistent atrial fibrillation: Very-high-power short-duration versus standard-power radiofrequency ablation
    Compagnucci, Paolo
    Volpato, Giovanni
    Cipolletta, Laura
    Parisi, Quintino
    Valeri, Yari
    Campanelli, Francesca
    D'Angelo, Leonardo
    Ciliberti, Giuseppe
    Stronati, Giulia
    Carboni, Laura
    Giovagnoni, Andrea
    Guerra, Federico
    Natale, Andrea
    Casella, Michela
    Dello Russo, Antonio
    HEART RHYTHM O2, 2024, 5 (06): : 374 - 384