Open Reduction and Internal Fixation of Distal Radius Fractures with Complete Intra-articular Involvement and Diaphyseal Extension

被引:0
|
作者
Oh, Chi-Hoon [1 ,3 ]
Jang, Inseok [1 ]
Ha, Cheungsoo [1 ]
Hong, In-Tae [2 ]
Jeong, Simho [1 ]
Han, Soo-Hong [1 ]
机构
[1] CHA Univ, CHA Bundang Med Ctr, Sch Med, Dept Orthoped Surg, Seongnam, South Korea
[2] Barunsesang Hosp, Hand & Foot Ctr, Seongnam, South Korea
[3] Korea Univ, Ansan Hosp, Dept Orthoped Surg, Ansan, South Korea
关键词
Distal radius fractures; Articular fracture; Diaphysis extension; Locking plate; volar approach; PLATE FIXATION; COMPLICATIONS;
D O I
10.4055/cios23385
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distal radius fractures with complete intra-articular involvement and diaphyseal extension pose significant challenges for stable fixation. Treatment options vary, with no single method demonstrating superiority. This study analyzed the outcomes of fixing these type of fractures with volar locking plates, which are widely used worldwide, and the fracture length according to plate type to determine when an extra-long plate should be used.<br /> Methods: This retrospective review analyzed 89 consecutive patients surgically treated for Association of Osteosynthesis (AO) classification type C distal radius fractures with diaphyseal extension, excluding open fractures. The plate length was determined to be long enough accordingly to avoid placing screws in the fracture site. Radiographic evaluation and clinical outcomes were analyzed.<br /> Results: According to the AO system, C3 type fractures comprised 50%, C1 type 28%, and C2 type 22%. The average distance from the radiocarpal joint to the most proximal fracture line was 41.1 mm, with articular step off and gap of 1.7 mm and 3.7 mm, respectively. Concomitant distal ulna fractures were present in 81%. At final follow-up, the mean radial height was 10.9 mm, radial inclination was 22.8 degrees, volar tilt was 5.7 degrees, and ulnar variance was 0.6 mm. Fracture union occurred on average at 2.6 months. The average Disabilities of the Arm, Shoulder, and Hand score was 12.0 and the average Modified Mayo Wrist Score was 83.6. Regarding the average wrist range of motion, extension was 63.8 degrees, flexion was 53.7 degrees, ulnar deviation was 25.1 degrees, and radial deviation was 16.7 degrees. Complications included delayed wound healing in 3% and delayed union in 1 patient, who eventually achieved union at 10 months after surgery. APTUS Wrist Distal Radius Plates XL 2.5 and 2.4-mm Variable Angle LCP Two-Column Volar Distal Radius Plates showed a statistically significant difference in fracture length, with the former being longer than the latter (62 mm vs. 35 mm, p < 0.001).<br /> Conclusions: If the fracture length from the articular surface to the diaphysis exceeds 60 mm, we recommend preparing an extra- long distal radius plate. Volar plate fixation with appropriate length selection has yielded favorable functional outcomes and few minor complications in distal radius fractures with complete intra-articular involvement and diaphyseal extension.
引用
收藏
页码:979 / 986
页数:8
相关论文
共 50 条
  • [41] Persian Fixation - A Novel Surgical Method for Intra-articular Distal Radius Fractures
    Fallah, Yousef
    Zohrabi, Kian
    Shariyate, Mohammad Javad
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (02): : 172 - 177
  • [42] Tangential views of articular surface of the distal radius - aid to open reduction and internal fixation of fractures
    Mandalia, V
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 (07): : 554 - 554
  • [43] OPEN REDUCTION AND INTERNAL-FIXATION FOR DISTAL RADIUS FRACTURES
    MISSAKIAN, ML
    COONEY, WP
    AMADIO, PC
    GLIDEWELL, HL
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (04): : 745 - 755
  • [44] Functional outcomes and cost estimation for extra-articular and simple intra-articular distal radius fractures treated with open reduction and internal fixation versus closed reduction and percutaneous Kirschner wire fixation
    Dzaja, Ivan
    MacDermid, Joy C.
    Roth, James
    Grewal, Ruby
    CANADIAN JOURNAL OF SURGERY, 2013, 56 (06) : 378 - 384
  • [45] Factors predicting adverse outcome in complete intra-articular distal radius fractures
    Hodel, Sandro
    Schraner, Christian
    Oehme, Florian
    van Leeuwen, Robbert
    Link, Bjorn-Christian
    Babst, Reto
    Beeres, Frank J. P.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2020, 46 (06) : 1413 - 1419
  • [46] Factors predicting adverse outcome in complete intra-articular distal radius fractures
    Sandro Hodel
    Christian Schraner
    Florian Oehme
    Robbert van Leeuwen
    Björn-Christian Link
    Reto Babst
    Frank J. P. Beeres
    European Journal of Trauma and Emergency Surgery, 2020, 46 : 1413 - 1419
  • [47] ASIF SCREW FIXATION FOR DIAPHYSEAL AND INTRA-ARTICULAR FRACTURES OF PHALANGES
    CRAWFORD, GP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (02): : 281 - 281
  • [48] The Volar Intra-Articular Extended Window Approach for Intra-Articular Distal Radius Fractures
    Kamal, Robin N.
    Ostergaard, Peter J.
    Shapiro, Lauren M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (05): : 516.e1 - 516.e5
  • [49] Arthroscopic management of intra-articular fractures of the distal radius
    Cognet, J. -M.
    Martinache, X.
    Mathoulin, C.
    CHIRURGIE DE LA MAIN, 2008, 27 (04) : 171 - 179
  • [50] Arthroscopic management of intra-articular distal radius fractures
    Geissler, WB
    Freeland, AE
    HAND CLINICS, 1999, 15 (03) : 455 - +