Open Reduction and Internal Fixation of Distal Radius Fractures with Complete Intra-articular Involvement and Diaphyseal Extension

被引:0
|
作者
Oh, Chi-Hoon [1 ,3 ]
Jang, Inseok [1 ]
Ha, Cheungsoo [1 ]
Hong, In-Tae [2 ]
Jeong, Simho [1 ]
Han, Soo-Hong [1 ]
机构
[1] CHA Univ, CHA Bundang Med Ctr, Sch Med, Dept Orthoped Surg, Seongnam, South Korea
[2] Barunsesang Hosp, Hand & Foot Ctr, Seongnam, South Korea
[3] Korea Univ, Ansan Hosp, Dept Orthoped Surg, Ansan, South Korea
关键词
Distal radius fractures; Articular fracture; Diaphysis extension; Locking plate; volar approach; PLATE FIXATION; COMPLICATIONS;
D O I
10.4055/cios23385
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distal radius fractures with complete intra-articular involvement and diaphyseal extension pose significant challenges for stable fixation. Treatment options vary, with no single method demonstrating superiority. This study analyzed the outcomes of fixing these type of fractures with volar locking plates, which are widely used worldwide, and the fracture length according to plate type to determine when an extra-long plate should be used.<br /> Methods: This retrospective review analyzed 89 consecutive patients surgically treated for Association of Osteosynthesis (AO) classification type C distal radius fractures with diaphyseal extension, excluding open fractures. The plate length was determined to be long enough accordingly to avoid placing screws in the fracture site. Radiographic evaluation and clinical outcomes were analyzed.<br /> Results: According to the AO system, C3 type fractures comprised 50%, C1 type 28%, and C2 type 22%. The average distance from the radiocarpal joint to the most proximal fracture line was 41.1 mm, with articular step off and gap of 1.7 mm and 3.7 mm, respectively. Concomitant distal ulna fractures were present in 81%. At final follow-up, the mean radial height was 10.9 mm, radial inclination was 22.8 degrees, volar tilt was 5.7 degrees, and ulnar variance was 0.6 mm. Fracture union occurred on average at 2.6 months. The average Disabilities of the Arm, Shoulder, and Hand score was 12.0 and the average Modified Mayo Wrist Score was 83.6. Regarding the average wrist range of motion, extension was 63.8 degrees, flexion was 53.7 degrees, ulnar deviation was 25.1 degrees, and radial deviation was 16.7 degrees. Complications included delayed wound healing in 3% and delayed union in 1 patient, who eventually achieved union at 10 months after surgery. APTUS Wrist Distal Radius Plates XL 2.5 and 2.4-mm Variable Angle LCP Two-Column Volar Distal Radius Plates showed a statistically significant difference in fracture length, with the former being longer than the latter (62 mm vs. 35 mm, p < 0.001).<br /> Conclusions: If the fracture length from the articular surface to the diaphysis exceeds 60 mm, we recommend preparing an extra- long distal radius plate. Volar plate fixation with appropriate length selection has yielded favorable functional outcomes and few minor complications in distal radius fractures with complete intra-articular involvement and diaphyseal extension.
引用
收藏
页码:979 / 986
页数:8
相关论文
共 50 条
  • [1] Displaced Intra-Articular Fractures of the Distal Radius: Open Reduction With Internal Fixation Versus Bridging External Fixation
    Fakoor, Mohammad
    Fakoor, Morteza
    Mohammadhoseini, Payam
    TRAUMA MONTHLY, 2015, 20 (03)
  • [2] Intra-articular fractures of the distal aspect of the radius: Arthroscopically assisted reduction compared with open reduction and internal fixation
    Doi, K
    Hattori, Y
    Otsuka, K
    Abe, Y
    Yamamoto, H
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (08): : 1093 - 1110
  • [3] OPEN REDUCTION AND INTERNAL-FIXATION OF DISPLACED, COMMINUTED INTRA-ARTICULAR FRACTURES OF THE DISTAL END OF THE RADIUS
    BRADWAY, JK
    AMADIO, PC
    COONEY, WP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (06): : 839 - 847
  • [4] Management of Complex Intra-Articular Distal Radius Fractures with Open Reduction and Internal Fixation with Double Dorsal Locking Plates
    Herdrich, S.
    Bauer, J.
    Pichl, J.
    Hoffmann, R.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (01): : 72 - 79
  • [5] Treatment of severely comminuted intra-articular fractures of the distal end of the radius by open reduction and combined internal and external fixation
    Rogachefsky, RA
    Lipson, SR
    Applegate, B
    Ouellette, EA
    Savenor, AM
    McAuliffe, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (04): : 509 - 519
  • [6] Intra-articular of the distal aspect of the radius: Arthroscopically assisted reduction compared with open reduction and internal fixation
    Peicha, G
    Seibert, FJ
    UNFALLCHIRURG, 2000, 103 (01): : 89 - 92
  • [7] Arthroscopic assessment of intra-articular distal radius fractures after open reduction and internal fixation from a volar approach
    Lutsky, Kevin
    Boyer, Martin I.
    Steffen, Jennifer A.
    Goldfarb, Charles A.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (04): : 476 - 484
  • [8] Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate
    Campbell, DA
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06): : 528 - 534
  • [9] Displaced intra-articular fractures of distal radius: a comparative evaluation of results following closed reduction, external fixation and open reduction with internal fixation
    Kapoor, H
    Agarwal, A
    Dhaon, BK
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (02): : 75 - 79
  • [10] Indirect reduction and percutaneous fixation versus open reduction and internal fixation for displaced intra-articular fractures of the distal radius - A randomised, controlled trial
    Kreder, HJ
    Hanel, DP
    Agel, J
    McKee, M
    Schemitsch, EH
    Trumble, TE
    Stephen, D