Performance improvement through CFD and field measurement in a unidirectional airflow cleanroom for wafer manufacture

被引:0
|
作者
Permana, Indra [1 ]
Agharid, Alya Penta [2 ]
Wang, Fujen [1 ]
机构
[1] Natl Chin Yi Univ Technol, Dept Refrigerat Air Conditioning & Energy Engn, Taichung 41170, Taiwan
[2] Natl Chin Yi Univ Technol, Grad Inst Precis Mfg, Taichung 41170, Taiwan
来源
关键词
Cleanroom; Airflow parallelism; Unidirectional airflow; Field measurement; CFD simulation; RAISED-FLOOR; CONTAMINATION;
D O I
10.1016/j.jobe.2024.111715
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In wafer grinding processes, maintaining strict contamination control in Class 1 cleanrooms is essential to prevent defects and ensure high product quality. However, achieving optimal unidirectional airflow remains a challenge, necessitating further research to improve cleanroom performance. This study investigates airflow performance and unidirectional airflow optimization in a cleanroom equipped with Ultra-Low Particulate Air (ULPA) filters. To ensure compliance with standards, Testing, Adjusting, and Balancing (TAB) were performed before conducting field measurements. The study explores the impact of varying Fan Filter Unit (FFU) air velocities, perforated floor porosities, and raised floor heights on airflow characteristics and turbulence within the cleanroom. Using Computational Fluid Dynamics (CFD) simulations and field measurements, we assessed FFU air velocities from 0.30 to 0.50 m/s, floor porosities of 17 %, 25 %, and 50 %, and raised floor heights of 400 mm, 600 mm, and 900 mm. The results demonstrated that decreasing FFU air velocity generally improved airflow uniformity and reduced turbulent kinetic energy (TKE), with notable enhancements at lower velocities. Perforated floor porosity had minimal impact on airflow distribution, whereas raised floor height significantly influenced turbulent intensity and airflow patterns. Higher raised floor heights led to smoother airflow and reduced turbulence. These findings underscore the importance of optimizing FFU air velocity and raised floor height to achieve effective cleanroom performance.
引用
收藏
页数:21
相关论文
共 42 条
  • [21] Acoustic field improvement through adjustable resonator to enhance the performance of thermoacoustic-Stirling engine
    Dhuchakallaya, Isares
    Jearsiripongkul, Thira
    Saechan, Patcharin
    ENERGY REPORTS, 2022, 8 : 979 - 985
  • [22] Performance Improvement of Membrane Stress Measurement Equipment through Evaluation of Added Mass of Membrane and Error Correction
    Jin, Sang-Wook
    Ohmori, Hiroshi
    Lee, Seungjae
    SHOCK AND VIBRATION, 2017, 2017
  • [23] Performance improvement of the sanitary centrifugal pump through an integrated approach based on response surface methodology, multi-objective optimization and CFD
    Thakkar, Sushil
    Vala, Henil
    Patel, Vivek K.
    Patel, Rajesh
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2021, 43 (01)
  • [24] Performance improvement of pentacene organic field-effect transistor through introducing polymer buffer layers
    Lufeng Shu
    Wei Shi
    Wei Huang
    Junsheng Yu
    Journal of Materials Science: Materials in Electronics, 2014, 25 : 5540 - 5545
  • [25] Performance improvement of pentacene organic field-effect transistor through introducing polymer buffer layers
    Shu, Lufeng
    Shi, Wei
    Huang, Wei
    Yu, Junsheng
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2014, 25 (12) : 5540 - 5545
  • [26] Performance improvement of the sanitary centrifugal pump through an integrated approach based on response surface methodology, multi-objective optimization and CFD
    Sushil Thakkar
    Henil Vala
    Vivek K. Patel
    Rajesh Patel
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2021, 43
  • [27] How to plan and manage library performance measurement projects through continuous improvement practice: USQ library experience
    Watson, TK
    PROCEEDINGS OF THE 2ND NORTHUMBRIA INTERNATIONAL CONFERENCE ON PERFORMANCE MEASUREMENT IN LIBRARIES AND INFORMATION SERVICES, 1998, : 239 - 259
  • [28] Improvement of field emission performance on nitrogen ion implanted ultrananocrystalline diamond films through visualization of structure modifications
    Chen, Ying-Chieh
    Zhong, Xiao-Yan
    Kabius, Bernd
    Hiller, Jon M.
    Tai, Nyan-Hwa
    Lin, I. -Nan
    DIAMOND AND RELATED MATERIALS, 2011, 20 (02) : 238 - 241
  • [29] Improvement of Field Emission Performance of Multilayered Porous Silicon-Based Electron Source Through Hydrogen Passivation
    He, Li
    Li, Sailei
    He, Qi
    Miao, Biqi
    Jiang, Qinglei
    Shen, Guiying
    Luo, Wei
    IEEE ELECTRON DEVICE LETTERS, 2024, 45 (10) : 1706 - 1709
  • [30] Measurement and improvement of emergency department performance through inspection and rating: an observational study of emergency departments in acute hospitals in England
    Allen, Thomas
    Walshe, Kieran
    Proudlove, Nathan
    Sutton, Matt
    EMERGENCY MEDICINE JOURNAL, 2019, 36 (06) : 326 - +