Comparison of digital study model superimposition methods using implant-supported crowns and best-fit algorithms

被引:1
|
作者
Meade, Maurice J. [1 ]
Weir, Tony [1 ]
Byrne, Graeme [2 ]
机构
[1] Univ Adelaide, Adelaide Dent Sch, Orthodont Unit, Adelaide Hlth & Med Sci Bldg,4 North Terrace, Adelaide, SA 5000, Australia
[2] La Trobe Univ, Stat Consultancy Platform, Melbourne, Vic, Australia
关键词
PALATAL SUPERIMPOSITION; INVISALIGN APPLIANCE; RELIABILITY; EXPRESSION; PREDICTABILITY; ACCURACY; MOVEMENT; SOFTWARE;
D O I
10.1016/j.ajodo.2024.06.009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Research regarding orthodontic changes using the superimposition of digital study models (DSMs) is commonplace. Information regarding the accuracy of data processing by superimposition software is limited. The study aimed to compare different methods of superimposing DSMs using implant-supported crowns (ISC) as a stable reference structure. Methods: DSMs containing ISCs were sourced from a database of patients treated with clear aligner therapy. The DSM representing the planned treatment outcome was superimposed on the pretreatment DSM. Three tooth points were selected for comparison on the contralateral side of each ISC. Differences in Cartesian coordinates for each tooth point for each arch superimposition method, used by the Geomagic Control X (3D systems, Rock Hill, NC) software system, were recorded. Paired ttests for the reference standard superimposition method best-fit high-resolution using the entire dental arch compared with initial, best-fit low-resolution, and best-fit high-resolution using the ISC only were calculated. Results: The DSMs of 54 dental arches containing ISCs were evaluated. All mean differences for displacements of selected points on the contralateral side to the ISC in the 3 Cartesian planes were <0.05 mm (P <0.05) and below the threshold of clinical significance. In addition, the standard superimposition techniques (initial, best-fit low-resolution, and best-fit high-resolution) resulted in nonstatistically significant and nonclinically significant differences in the position of the ISC. Conclusions: Researchers can be confident that the described superimposition methodologies, with and without ISCs as a stable reference structure, are a valid method for accurately assessing most
引用
收藏
页数:11
相关论文
共 46 条
  • [21] Classification Algorithms Comparison for Interturn Short-Circuit Recognition in Induction Machines Using Best-Fit 3-D-Ellipse Method
    Maitre, Julien
    Bouchard, Bruno
    Bouzouane, Abdenour
    Gaboury, Sebastien
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2018, 40 (04): : 255 - 265
  • [22] Clinical, Technical, and Radiologic Outcomes of 182 Implant-Supported Zirconia Single Crowns Using Titanium-Base Abutments: A Retrospective Study
    Guncu, Mustafa Baris
    Aktas, Guliz
    Guncu, Guliz N.
    Anil, Duygu
    Turkyilmaz, Ilser
    Antonoff, Lisa R.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (04) : 553 - 559
  • [23] Temporary Implant-Supported Single Crowns Using Titanium Base Abutments: An In Vitro Study on Bonding Stability and Pull-out Forces
    Pitta, Joao
    Bijelic-Donova, Jasmina
    Burkhardt, Felix
    Fehmer, Vincent
    Narhi, Timo
    Sailer, Irena
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (05) : 546 - 552
  • [24] Effect of geometry on deformation of anterior implant-supported zirconia frameworks: An in vitro study using digital image correlation
    Calha, Nuno
    Messias, Ana
    Guerra, Fernando
    Martinho, Beatriz
    Augusta Neto, Maria
    Nicolau, Pedro
    JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (02) : 139 - 148
  • [25] Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems
    Kayikci, Ozlem
    Ates, Sabit Melih
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (02) : 1283 - 1291
  • [26] Comparison of the accuracy between conventional and various digital implant impressions for an implant-supported mandibular complete arch-fixed prosthesis: An in vitro study
    Kosago, Pitchaporn
    Ungurawasaporn, Chatcharwin
    Kukiattrakoon, Boonlert
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (07): : 616 - 624
  • [27] Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems
    Ozlem Kayikci
    Sabit Melih Ates
    Clinical Oral Investigations, 2022, 26 : 1283 - 1291
  • [28] Comparison between stereophotogrammetric, digital, and conventional impression techniques in implant-supported fixed complete arch prostheses: An in vitro study
    Tohme, Hani
    Lawand, Ghida
    Chmielewska, Maja
    Makhzoume, Joseph
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (02): : 354 - 362
  • [29] Model-less digital workflow for the replication of an existing complete fixed implant-supported prosthesis using an intraoral scanner
    Markarian, Roberto A.
    Feitosa Filho, Marco
    Vasconcelos, Ednaria
    CLINICAL CASE REPORTS, 2019, 7 (03): : 500 - 505
  • [30] Accuracy of Proximal and Occlusal Contacts of Single Implant Crowns Fabricated Using Different Digital Scan Methods: An In Vitro Study
    Ren, Xi
    Son, Keunbada
    Lee, Kyu-Bok
    MATERIALS, 2021, 14 (11)