Comparison of digital study model superimposition methods using implant-supported crowns and best-fit algorithms

被引:1
|
作者
Meade, Maurice J. [1 ]
Weir, Tony [1 ]
Byrne, Graeme [2 ]
机构
[1] Univ Adelaide, Adelaide Dent Sch, Orthodont Unit, Adelaide Hlth & Med Sci Bldg,4 North Terrace, Adelaide, SA 5000, Australia
[2] La Trobe Univ, Stat Consultancy Platform, Melbourne, Vic, Australia
关键词
PALATAL SUPERIMPOSITION; INVISALIGN APPLIANCE; RELIABILITY; EXPRESSION; PREDICTABILITY; ACCURACY; MOVEMENT; SOFTWARE;
D O I
10.1016/j.ajodo.2024.06.009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Research regarding orthodontic changes using the superimposition of digital study models (DSMs) is commonplace. Information regarding the accuracy of data processing by superimposition software is limited. The study aimed to compare different methods of superimposing DSMs using implant-supported crowns (ISC) as a stable reference structure. Methods: DSMs containing ISCs were sourced from a database of patients treated with clear aligner therapy. The DSM representing the planned treatment outcome was superimposed on the pretreatment DSM. Three tooth points were selected for comparison on the contralateral side of each ISC. Differences in Cartesian coordinates for each tooth point for each arch superimposition method, used by the Geomagic Control X (3D systems, Rock Hill, NC) software system, were recorded. Paired ttests for the reference standard superimposition method best-fit high-resolution using the entire dental arch compared with initial, best-fit low-resolution, and best-fit high-resolution using the ISC only were calculated. Results: The DSMs of 54 dental arches containing ISCs were evaluated. All mean differences for displacements of selected points on the contralateral side to the ISC in the 3 Cartesian planes were <0.05 mm (P <0.05) and below the threshold of clinical significance. In addition, the standard superimposition techniques (initial, best-fit low-resolution, and best-fit high-resolution) resulted in nonstatistically significant and nonclinically significant differences in the position of the ISC. Conclusions: Researchers can be confident that the described superimposition methodologies, with and without ISCs as a stable reference structure, are a valid method for accurately assessing most
引用
收藏
页数:11
相关论文
共 46 条
  • [1] Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis
    Moris, Izabela C. M.
    Monteiro, Silas Borges
    Martins, Raissa
    Ribeiro, Ricardo Faria
    Gomes, Erica A.
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [2] Evaluation of fracture resistance and marginal fit of implant-supported interim crowns fabricated by conventional, additive and subtractive methods
    Elsareef, Safaa Salah
    Azer, Amir Shokry
    Morsy, Noha
    BMC ORAL HEALTH, 2024, 24 (01):
  • [3] A randomized clinical trial comparing the clinical fit and chairside adjustment time for implant-supported crowns fabricated by fully digital and partially digital techniques
    Haghi, Hamidreza Rajati
    Ghanbarzadeh, Jalil
    Kiamanesh, Ehsan
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (05): : 865 - 870
  • [4] Evaluation of marginal fit of single implant-supported metal-ceramic crowns prepared by using presintered metal blocks
    Pasali, Baris
    Sarac, Duygu
    Kaleli, Necati
    Sarac, Yakup Sinasi
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (02): : 257 - 262
  • [5] In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns
    Aristeidis A. Villias
    Stefanos G. Kourtis
    Hercules C. Karkazis
    Gregory L. Polyzois
    International Journal of Implant Dentistry, 7
  • [6] In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns
    Villias, Aristeidis A.
    Kourtis, Stefanos G.
    Karkazis, Hercules C.
    Polyzois, Gregory L.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [7] Clinical and laboratory passive fit assessment of implant-supported zirconia restorations fabricated using conventional and digital workflow
    Rutkunas, Vygandas
    Larsson, Christel
    von Steyern, Per Vult
    Mangano, Francesco
    Gedrimiene, Agne
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (02) : 237 - 245
  • [8] Digital versus conventional prosthetic workflow for dental students providing implant-supported single crowns: A randomized crossover study
    Seth, Chahak
    Bawa, Annika
    Gotfredsen, Klaus
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 450 - 456
  • [9] Accuracy of different digital acquisition methods in complete arch implant-supported prostheses: An in vitro study
    Pinto, Ricardo J.
    Casado, Sara A.
    Chmielewski, Krzysztof
    Carames, Joao M.
    Marques, Duarte S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 172 - 177
  • [10] A study on the fracture strength of implant-supported restorations using milled ceramic abutments and all-ceramic crowns
    Cho, HW
    Dong, JK
    Jin, TH
    Oh, SC
    Lee, HH
    Lee, JW