D-dimer assay interference detected by the discrepancy in D-dimer concentrations at different dilutions: a case report

被引:0
|
作者
Milic, Marija [1 ,2 ]
Barbaric, Dejana Brkic [3 ]
Lukic, Iva [1 ,2 ]
Kirin, Mirna [4 ]
Buljanovic, Vikica [5 ]
Seric, Vatroslav [1 ,2 ]
机构
[1] Univ Hosp Ctr Osijek, Clin Inst Lab Diagnost, Osijek, Croatia
[2] Univ Osijek, Fac Med, Dept Med Chem Biochem & Clin Chem, Osijek, Croatia
[3] Univ Hosp Ctr Osijek, Clin Inst Transfus Med, Osijek, Croatia
[4] Siemens Healthineers, Siemens Healthcare doo, Zagreb, Croatia
[5] Gen Hosp Nasice, Med Biochem Lab, Nashice, Croatia
关键词
D-dimer; heterophile antibodies; blood coagulation tests; interference;
D O I
10.11613/BM.2024.031001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
This case report describes interference from heterophilic antibodies in D-dimer assay. The interference was suspected due to discrepancies between D-dimer concentrations in the original sample and diluted samples, as well as inconsistent clinical findings. The patient's medical history, laboratory results, and imaging studies were considered in the investigation. Heterophilic antibodies, likely developed during the SARS-CoV-2 infection, were identified as the probable cause of interference. The interference was confirmed through various methods, including dilution studies, blocking heterophilic antibodies, and comparing results with an alternative D-dimer method. This case highlights the importance of recognizing and addressing interference in D-dimer testing, emphasizing the need for collaboration between clinicians and laboratory specialists.
引用
收藏
页数:7
相关论文
共 50 条
  • [42] D-dimer Changes in a Patient with ROHHAD Syndrome: A Case Report
    Yang, M. J.
    Zheng, Z. C.
    Shan, X. O.
    Lin, J.
    HONG KONG JOURNAL OF PAEDIATRICS, 2024, 29 (04) : 254 - 257
  • [43] Awareness on D-dimer assay among dental students
    Anjum, Shamaa
    Ahmed, Nabeel
    Ganapathy, Dhanraj M.
    Maiti, Subhabrata
    Pandurangan, Kiran Kumar
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S223 - S227
  • [44] MEASUREMENT OF D-DIMER WITH AN ENZYME-IMMUNO-ASSAY
    AMIRAL, J
    ADALBERTBIRON, B
    CANTON, M
    THROMBOSIS RESEARCH, 1986, : 33 - 33
  • [45] d-Dimer Plasma Concentrations in an Older Hospitalized Population
    Isaia, Gianluca
    Bertone, Paola
    Bo, Mario
    Greppi, Francesca
    Roet, Katia Molinar
    Ausiello, Livia
    Ruatta, Claudia
    Sapone, Pasqualina
    Zanocchi, Mauro
    Isaia, Giovanni C.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2011, 59 (12) : 2385 - 2386
  • [46] Limited interobserver agreement in the SimpliRED D-dimer assay
    Perzanowski, C
    Eiger, G
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2003, 1 (04) : 849 - 850
  • [47] Rapid assay for determining D-Dimer levels in pregnancy
    Manrique, Maritza
    Ortwein, Sherry
    Anasti, James N.
    OBSTETRICS AND GYNECOLOGY, 2006, 107 (04): : 99S - 99S
  • [48] Development of Rapid Immunochromatographic Assay for D-dimer Detection
    Byzova, N. A.
    Zherdev, A. V.
    Pridvorova, S. M.
    Dzantiev, B. B.
    APPLIED BIOCHEMISTRY AND MICROBIOLOGY, 2019, 55 (03) : 305 - 312
  • [49] D-dimer assay during menstrual period.
    Chan, HH
    Johnson, JA
    Panju, A
    Bradley, CA
    BLOOD, 2004, 104 (11) : 94B - 95B
  • [50] SimpliRed D-dimer assay in suspected pulmonary embolus
    Harrison, M
    JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 2000, 17 (06): : 404 - 405