Potential of High-Intensity Focused Ultrasound in Enamel Remineralization

被引:0
|
作者
Shrestha, B. [1 ]
Rajan, S. M. [1 ]
Saunders, M. [2 ]
Fawzy, A. [1 ]
机构
[1] Univ Western Australia, UWA Dent Sch, 17 Monash Ave, Nedlands, WA 6009, Australia
[2] Univ Western Australia, Ctr Microscopy Characterisat & Anal, Nedlands, WA, Australia
关键词
ultrasonic energy; minimal invasive dentistry; enamel white spot lesions; enamel repair; cariogenic biofilms; biomaterials; CALCIUM-PHOSPHATE; HYDROXYAPATITE NANORODS; NANOPARTICLES; FLUORIDE; AMELOGENIN; LESIONS;
D O I
10.1177/00220345251323869
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Remineralization is an essential interventional strategy for intercepting enamel white spot lesions (WSLs). Given the limitations of both natural and/or fluoride-mediated repair processes, there is a need to develop novel strategies for repairing enamel WSLs via a minimally invasive approach while restoring the unique ultrastructural integrity and functional properties. Inspired by the unique capability of high-intensity focused ultrasound (HIFU) in facilitating the crystallization process, we propose a novel strategy of employing HIFU for in vitro repair of WSLs through synergizing the crystallization process required for hydroxyapatite (HAP) formation from its precursor (calcium phosphate ion clusters; CPICs). Following CPIC formulation and characterization including the resultant amorphous calcium phosphate (ACP), the effect of HIFU on the ACP-to-HAP transition on the amorphous substrate was investigated using transmission electron microscopy and high-resolution transmission electron microscopy, selected area electron diffraction, and X-ray diffraction (XRD). The results showed profound amorphous-to-crystalline phase transition, within 5- to 30-min HIFU exposure, whereas the long axis of the resultant HAP corresponded with the (002) plane, and a lattice spacing of 0.34 nm indicated a preferred c-axis growth direction consistent with the orientation of natural enamel crystallites. For enamel repair, artificial WSLs were created on enamel specimens and then subjected to CPICs, followed by HIFU exposure for 2.5, 5, or 10 min. Scanning electron and atomic force microscopies revealed the decreased surface roughness and the gradual obliteration in the WSL porous structure with continuous linear coaxial arrangement of HAP crystallites filling the prismatic/interprismatic gaps closely resembling sound enamel specifically with 5-min HIFU exposure. Enamel WSL ultrastructural repair was further confirmed from XRD and Raman spectral analyses with the associated regaining of mineral density and nanomechanical properties as reflected from micro-computed tomography (CT) and nanoindentation results, respectively. Micro-CT further validated the subsurface remineralization of WSLs with HIFU exposure. Within the same exposure parameters, HIFU exhibited a potent antibiofilm effect against Streptococcus mutans. This study introduced a new approach for remineralizing enamel WSLs through the potent synergy between HIFU and CPICs.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] New use found for the high-intensity focused ultrasound
    Hu, Z.
    Yang, X. Y.
    Liu, Y.
    EXPERT REVIEW OF MEDICAL DEVICES, 2007, 4 (05) : 681 - 682
  • [32] EFFECTS OF HIGH-INTENSITY FOCUSED ULTRASOUND ON HUMAN PROSTATE
    GELET, A
    CHAPELON, JY
    JOURNAL D UROLOGIE, 1993, 99 (06) : 350 - 350
  • [33] HIGH-INTENSITY FOCUSED ULTRASOUND SCATTERING AT MAMMAL VERTEBRAE
    Sanford, David
    Schaal, Christoph
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 5, 2020,
  • [34] Liver hemostasis using high-intensity focused ultrasound
    Vaezy, S
    Martin, R
    Schmiedl, U
    Caps, M
    Taylor, S
    Beach, K
    Carter, S
    Kaczkowski, P
    Keilman, G
    Helton, S
    Chandler, W
    Mourad, P
    Rice, M
    Roy, R
    Crum, L
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (09): : 1413 - 1420
  • [35] High-intensity focused ultrasound and radiotherapy: a promising combination?
    Adema, G.
    Van den Bijgaart, R.
    Raaijmakers, T.
    Den Brok, M.
    Hoogenboom, M.
    Futterer, J.
    Bussink, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S75 - S75
  • [36] Effects of high-intensity focused ultrasound on nerve conduction
    Foley, Jessica L.
    Little, James W.
    Vaezy, Shahram
    MUSCLE & NERVE, 2008, 37 (02) : 241 - 250
  • [37] HIGH-INTENSITY FOCUSED ULTRASOUND IN THE TREATMENT OF PROSTATIC DISEASE
    FOSTER, RS
    BIHRLE, R
    SANGHVI, NT
    FRY, FJ
    DONOHUE, JP
    EUROPEAN UROLOGY, 1993, 23 : 29 - 33
  • [38] Lens Opacity Following High-Intensity Focused Ultrasound
    Strauss, Rupert W.
    Bolz, Matthias
    JAMA OPHTHALMOLOGY, 2020, 138 (02) : 215 - 216
  • [39] Integration of photoacoustic imaging and high-intensity focused ultrasound
    Cui, Huizhong
    Staley, Jacob
    Yang, Xinmai
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (02)
  • [40] Emerging clinical applications of high-intensity focused ultrasound
    Nguyen Minh Duc
    Keserci, Bilgin
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2019, 25 (05) : 398 - 409