A comparison of fetal hemoglobin interference in routine high-performance liquid chromatography, immunoassay, and enzymatic methods of glycated hemoglobin measurement

被引:0
|
作者
Soh, Sheila X. [1 ]
Loh, Tze Ping [1 ]
Liu, Qinde [2 ]
Liu, Hong [2 ]
Tjai, Madeline [2 ]
Tan, Hwee Tong [2 ]
Teo, Tang Lin [2 ]
Hawkins, Robert C. [1 ,3 ]
Sethi, Sunil K. [1 ]
Ong, Lizhen [1 ]
机构
[1] Natl Univ Singapore Hosp, Dept Lab Med, Singapore, Singapore
[2] Hlth Sci Author, Chem Metrol Div, Appl Sci Grp, Singapore, Singapore
[3] Tan Tock Seng Hosp, Dept Lab Med, Singapore, Singapore
关键词
interference; hemoglobinopathy; HbA(1c); glycated hemoglobin; fetal hemoglobin; HEREDITARY PERSISTENCE; A(1C); HBA1C;
D O I
10.1093/labmed/lmae109
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Fetal hemoglobin (HbF) is known to cause method-specific interference in glycated hemoglobin A(1c) (HbA(1c)) measurement. Data on HbF interference, however, is currently either lacking for some platforms (eg, the Abbott Core Laboratory Alinity c and Beckman Coulter AU5800) or available only for HbF levels lower than the maximum claimed by the manufacturer (eg, Bio-Rad D-100). Methods: We examined the effect of HbF interference on 7 HbA(1c) platforms using a series of spiked adult whole blood samples with increasing HbF levels (0% to 35%) and either low (approximately 5%) or high (approximately 9%) HbA(1c) levels, using isotope dilution mass spectrometry as a reference measurement procedure. Results: For the high-performance liquid chromatography (HPLC)-based platforms (Bio-Rad VARIANT II TURBO 2.0 and D-100), relative deviation from expected values was not clinically significant, even at an HbF level of 35%. In contrast, immunoassay (AU5800; Roche Diagnostics cobas c311 and cobas b101; and Siemens Healthineers DCA Vantage) and enzymatic (Alinity c) methods showed clinically significant deviation at HbF levels above 10%. Discussion: Our data suggest that the HPLC methods tested can be used for the majority of patients with elevated HbF. For patients with HbF levels above 10%, immunoassay and enzymatic methods appear to be unsuitable, and alternative HbA(1c) methods are still advised.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF HEMOGLOBIN - THE INFLUENCE OF HEMOGLOBIN-S ON HEMOGLOBIN A2 QUANTITATION
    SUH, DD
    KRAUSS, JS
    BURES, K
    BLOOD, 1994, 84 (10) : A559 - A559
  • [22] Comparison of four chromatographic methods used for measurement of glycated hemoglobin
    Nemes-Nagy, Eniko
    Fazakas, Zita
    Balogh-Samarghitan, Victor
    Simon-Szabo, Zsuzsanna
    Denes, Lorand
    Uzun, Cosmina Cristina
    Fodor, Marta Andrea
    Tilinca, Mariana Cornelia
    Reid, Deborah
    Higgins, Trefor
    REVISTA ROMANA DE MEDICINA DE LABORATOR, 2016, 24 (04): : 431 - 439
  • [23] Degradation analysis of human hemoglobin by high-performance liquid chromatography
    Row, KH
    Lee, SK
    Polyakova, Y
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2004, 10 (03) : 478 - 483
  • [24] DETERMINATION OF CARBAMYLATED HEMOGLOBIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KWAN, JTC
    CARR, EC
    BENDING, MR
    BARRON, JL
    CLINICAL CHEMISTRY, 1990, 36 (04) : 607 - 610
  • [25] IDENTIFICATION OF FETAL HEMOGLOBIN AND SIMULTANEOUS ESTIMATION OF BLOODSTAIN AGE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    INOUE, H
    TAKABE, F
    IWASA, M
    MAENO, Y
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 1991, 104 (03) : 127 - 131
  • [26] Analytical calibre of high performance liquid chromatography and ion exchange chromatography resin methods in estimation of glycated hemoglobin: a comparitive study
    Rukmini, M. S.
    Ashritha
    Nishmitha, P.
    Yalla, D.
    Christy, A.
    Manjrekar, P.
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (04): : 1765 - 1769
  • [27] Effect of hemoglobin Porto Alegre on glycated hemoglobin (HbA1c) measurement with the HA-8160 high performance liquid chromatography method
    Lorenzo-Medina, Mercedes
    De-La-Iglesia, Silvia
    Ropero, Paloma
    Martin-Aguila, Adys
    Ruiz-Garcia, Lidia
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (10) : E247 - E249
  • [28] INCIDENCE AND INTERFERENCE OF HEMOGLOBIN VARIANTS ON HBA1C MEASUREMENT USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY AND CAPILLARY ELECTROPHORESIS
    Van den Bossche, Jan
    Asselman, Valerie
    Luyckx, Kim
    De Block, Christophe
    Van Gaal, Luc
    Van Hoof, Viviane
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 : 111 - 111
  • [29] MEASUREMENT OF PROINSULIN AND INTERMEDIATES - VALIDATION OF IMMUNOASSAY METHODS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    OSTREGA, D
    POLONSKY, K
    NAGI, D
    YUDKIN, J
    COX, LJ
    CLARK, PMS
    HALES, CN
    DIABETES, 1995, 44 (04) : 437 - 440
  • [30] Anti-interference hemoglobin analysis system by high performance liquid chromatography
    Xu, Yan
    Yao, Tiantian
    Hu, Wenyong
    Zhang, Bo
    Guo, Xingming
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2021, 38 (05): : 940 - 950