Macular Oxygen Saturation in Glaucoma Using Retinal Oximetry of Visible Light Optical Coherence Tomography: A Pilot Study

被引:0
|
作者
Wang, Jingyu [1 ]
Sadlak, Natalie [2 ]
Fiorello, Marissa G. [2 ]
Desai, Manishi [2 ]
Yi, Ji [1 ,3 ,4 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Ophthalmol, Baltimore, MD USA
[2] Boston Med Ctr, Dept Ophthalmol, Boston, MA USA
[3] Boston Univ, Boston Med Ctr, Sch Med, Dept Med, Boston, MA USA
[4] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD USA
来源
关键词
visible light optical coherence tomography; retinal oximetry; glaucoma; GANGLION-CELL FUNCTION; NERVE-FIBER LAYER; OCT; THICKNESS; VESSELS; DAMAGE; ANGIOGRAPHY; METABOLISM;
D O I
10.1167/tvst.14.2.12
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: A cross-sectional pilot study to compare macular oxygen saturation (sO2) and associated clinical measurements between normal and glaucoma subjects and to evaluate whether macular sO2 can be a diagnostic metric for early-stage glaucoma. Methods: Forty-eight eyes of 35 subjects from three groups were included: normal subjects (16 eyes, 10 subjects), suspect/pre-perimetric glaucoma (GS/PPG) subjects (17 eyes, 12 subjects), and perimetric glaucoma (PG) subjects (15 eyes, 13 subjects). We performed retinal oximetry of visible light optical coherence tomography (VIS-OCT) in macular vessels, with 512 x 256 sampling points over a 5 x 5 mm2 area. Zeiss Cirrus OCT scans and a 24-2 visual field test (VFT) were conducted. Statistical analysis was conducted. Results: Significant differences were observed among the three groups for all VIS-OCT, Zeiss OCT, and VFT variables. As glaucoma severity increased, macular AsO2 (arterial sO2) and A-V sO2 (arteriovenous sO2 difference) decreased, whereas macular VsO2 (venous sO2) increased. Macular AsO2 and A-V sO2 were found to be statistically correlated with ganglion cell layer + inner plexiform layer (GCL+IPL) and circumpapillary retinal nerve fiber layer in all eyes, as well as in PG eyes. Within the PG group, a dominant correlation between AsO2 and ganglion cell layer+ inner plexiform layer was observed in the more damaged lower hemifield. Conclusions: Glaucoma subjects showed altered macular sO2, indicating reduced oxygen consumption. The sO2 measured by VIS-OCT could be a potential metric for early glaucoma diagnosis. Translational Relevance: This study shows macular sO2 measurements via VIS-OCT could bridge advanced imaging technology and clinical glaucoma detection.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Visible light optical coherence tomography measures retinal oxygen metabolic response to systemic oxygenation
    Yi, Ji
    Liu, Wenzhong
    Chen, Siyu
    Backman, Vadim
    Sheibani, Nader
    Sorenson, Christine M.
    Fawzi, Amani A.
    Linsenmeier, Robert A.
    Zhang, Hao F.
    LIGHT-SCIENCE & APPLICATIONS, 2015, 4 : e334 - e334
  • [22] Retinal oximetry using ultrahigh-resolution optical coherence tomography
    Ye, Yufeng
    Jiang, Hong
    Shen, Meixiao
    Lam, Byron L.
    DeBuc, Delia Cabrera
    Ge, Lili
    Sehi, Mitra
    Wang, Jianhua
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 2085 - 2092
  • [23] Macular imaging with optical coherence tomography in glaucoma
    Mohammadzadeh, Vahid
    Fatehi, Nima
    Yarmohammadi, Adeleh
    Lee, Ji Woong
    Sharifipour, Farideh
    Daneshvar, Ramin
    Caprioli, Joseph
    Nouri-Mahdavi, Kouros
    SURVEY OF OPHTHALMOLOGY, 2020, 65 (06) : 597 - 638
  • [24] Macular Optical Coherence Tomography Imaging in Glaucoma
    Kamalipour, Alireza
    Moghimi, Sasan
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2021, 16 (03) : 478 - 489
  • [25] Pilot Study of Optical Coherence Tomography Measurements of Retinal Vessel Relief Height in the Detection of Glaucoma
    Tan, Ou
    Tehrani, Shandiz
    Orozco, Brandon V.
    Wang, Xiaogang
    Jia, Yali
    Kraus, Martin F.
    Fujimoto, James G.
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [26] Depth-gated Fourier transform to accelerate spectral recovery in visible light optical coherence tomography retinal oximetry
    Nolen, Stephanie l.
    Wang, Jingyu
    Yi, Ji
    OPTICS LETTERS, 2025, 50 (04) : 1061 - 1064
  • [27] Visible light optical coherence tomography to quantify retinal blood oxygenation
    Yi, Ji
    Liu, Wenzhong
    Zhang, Hao F.
    2014 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2014,
  • [28] Projection-Resolved Optical Coherence Tomography Angiography of Macular Retinal Circulation in Glaucoma
    Takusagawa, Hana L.
    Liu, Liang
    Ma, Kelly N.
    Jia, Yali
    Gao, Simon S.
    Zhang, Miao
    Edmunds, Beth
    Parikh, Mansi
    Tehrani, Shandiz
    Morrison, John C.
    Huang, David
    OPHTHALMOLOGY, 2017, 124 (11) : 1589 - 1599
  • [29] Optical Coherence Tomography Angiography in Uveitic Glaucoma - A Pilot Study
    Lommatzsch, C.
    Bauermann, P.
    Heimes-Bussmann, B.
    Nolte, C.
    Heinz, C.
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2021, 29 (7-8) : 1410 - 1416
  • [30] Visible light optical coherence tomography for microvascular oximetry in ocular circulation (Conference Presentation)
    Chen, Siyu
    Yi, Ji
    Zhang, Hao F.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697